[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-500107-105":59,"doc-detail-500107-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","system-fsc-4-fire-stop-collar-pipe-penetration-seal-european-technical-assessment","System FSC 4 Fire Stop Collar - Pipe Penetration Seal - European Technical Assessment","","European Technical Assessment ETA-15/0907 specifies the System FSC 4 Fire Stop Collar pipe penetration seal as a fire-stopping and fire-sealing component for pipes passing through walls and floors. It describes a steel metal casing with corrosion protection and an intumescent lining made of “ROKU® Strip EM”, including permitted wall and floor thicknesses. The intended use preserves fire resistance by preventing heat transmission and fire spread at penetrations. Reaction to fire classifications are provided, and the assessment assumes a working life of at least 10 years.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/system-fsc-4-fire-stop-collar-pipe-penetration-seal-european-technical-assessment/500107/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/system-fsc-4-fire-stop-collar-pipe-penetration-seal-european-technical-assessment/500107.png","ImageObject",300,407,{"name":92,"@type":93},"jay","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-22","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What product is covered by ETA-15/0907?","Question",{"text":112,"@type":113},"ETA-15/0907 covers the System FSC 4 Fire Stop Collar pipe penetration seal used to seal pipe openings in fire-resistant walls and floors.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the system work in fire-stopping applications?",{"text":117,"@type":113},"Its fire-resistant capability prevents heat transmission and helps stop fire spreading around penetrations, preserving the wall’s fire resistance in the event of fire.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the reaction-to-fire classifications stated in the assessment?",{"text":121,"@type":113},"The steel collar housing is classified Euroclass A1 and the intumescent “ROKU® Strip EM” material is classified Euroclass E, both according to EN 13501-1 and delegated regulation 2016/364.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},500107,1791302760,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3985747858866,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","ETA-Danmark A/SGöteborg Plads 1  \nDK-2150 Nordhavn  \nTel. +45 72 24 59 00 [Internet www.etadanmark.dk](Internet www.etadanmark.dk)  \nAuthorised and notified according to Article 29 of the Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011  \nMEMBER OF EOTA  \nEuropean Technical Assessment ETA-15/0907 of 2024/11/04  \nGeneral Part  \nTechnical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: ETA-Danmark A/S  \nManufacturer:  \nThis European Technical Assessment is issued in accordance with Regulation (EU) No 305/2011, on the  \nThis version replaces:  \nSystem FSC 4 Fire Stop Collar  \nFire Stopping and Sealing with penetration seals for pipes in walls and floors.  \nFlamro Brandschutz-Systeme GmbH Am Sportplatz 2  \nDE-56291 Leiningen Tel +49 4105 4090 0 [Internet:](Internet: www.flamro.de)[ ](Internet: www.flamro.de)[www.flamro.de](Internet: www.flamro.de)  \nPlant LEI  \n17 pages including 3 annexes which form an integral part of the document  \nEAD 350454-00-1104:  \nFire stopping and fire sealing products-Penetration seals  \nThe ETA with the same number issued on 2016-01-04  \nabove construction product  \nbasis of:  \nTranslations of this European Technical Assessment in other languages shall fully correspond to the original issued document and should be identified as such.  \nCommunication of this European Technical Assessment, including transmission by electronic means, shall be in full (excepted the confidential Annex(es) referred to above). However, partial reproduction may be made, with the written consent of the issuing Technical Assessment Body. Any partial reproduction has to be identified as such  \nII SPECIFIC PART OF THE  \nEUROPEAN TECHNICAL  \nASSESSMENT  \n1 Technical description of the product.  \nThe System FSC 4 Fire Stop Collar pipe penetration seal, pipe collar with straps for plug fixing or embedding in mortar, gypsum. The System FSC 4 Fire Stop Collar pipe penetration seal consists of a metal casing of steel with a minimum thickness of 0,60 mm sufficiently protected against corrosion, and a fire protection lining located inside the housing. The lining consists of a 2 mm thick and 40 mm wide intumescent building material “ROKU® Strip EM” with a density of approx. 1210 ± 10 kg/m3.  \nThe collars have an outer diameter of 61,2 mm up to 187,2 mm. The System FSC 4 Fire Stop Collar pipe penetration seal is permitted in lightweight partition walls and solid walls with a thickness of at least 100 mm and in solid floors with a thickness of at least 150 mm. The radial clearance between the penetrating plastic pipes – including insulation – and the vertical or horizontal building part closing off the room must be filled completely with mineral building materials.  \nDetailed specifications for identification and performance criteria relevant for fire safety regarding the construction products are given in annexes 1-3.  \n2 Specification of the intended use(s) in accordance with the applicable European Assessment Document (hereinafter EAD)  \nThe construction product System FSC 4 Fire Stop Collar pipe penetration seal is intended for use as components with a fire protection effect in walls made from concrete, aerated concrete, masonry, or light weight partition structures that are subject to requirements related to fire protection. Their fire-resistant capability prevents heat transmission and fire spreading in the event of fire. Within the scope of this ETA, the fire resistance was demonstrated for pipes in penetration seals which consisted of the components listed in table 1.  \nTable 1 – components of the verified penetration seals  \n\n| Product type | Trade name |\n| --- | --- |\n| Collar | System FSC 4 Fire Stop Collar |\n| Intumescent | Strip EM |\n\nPipe penetration seals are used to seal off openings in fire resistant walls, which are penetrated by cables, and serves to preserve the walls' fire resistance around the penetrations.  \nDetailed inf","cbCaikTjWwEV2NiX","https://ap.wps.com/l/cbCaikTjWwEV2NiX","pdf",726166,17,"English","# II Specific Part of the European Technical Assessment\n## 1 Technical description of the product\n## 2 Intended use(s) according to EAD\n## 3 Performance of the product and assessment methods\n### 3.2 Safety in case of fire (BWR 2)\n### 3.3 Hygiene, health and the environment (BWR 3)\n### 3.4 Safety and accessibility in use (BWR 4)","[{\"question\":\"What product is covered by ETA-15/0907?\",\"answer\":\"ETA-15/0907 covers the System FSC 4 Fire Stop Collar pipe penetration seal used to seal pipe openings in fire-resistant walls and floors.\"},{\"question\":\"How does the system work in fire-stopping applications?\",\"answer\":\"Its fire-resistant capability prevents heat transmission and helps stop fire spreading around penetrations, preserving the wall’s fire resistance in the event of fire.\"},{\"question\":\"What are the reaction-to-fire classifications stated in the assessment?\",\"answer\":\"The steel collar housing is classified Euroclass A1 and the intumescent “ROKU® Strip EM” material is classified Euroclass E, both according to EN 13501-1 and delegated regulation 2016/364.\"}]","System FSC 4 Fire Stop Collar - Pipe Penetration Seal - European Technical Assessment | PDF",1791008633,43]