[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-500007-105":59,"doc-detail-500007-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","system-fsc-4-fire-resistant-penetration-sealing-system","System FSC 4 - Fire-resistant penetration sealing system","","System FSC 4 installation instructions describe a fire-resistant penetration sealing system for plastic pipes with medium diameters, designed in accordance with ETA-15/0907 and classified up to EI 240 U/C per EN 13501-2. The document sets out who may install the system, how to use the instructions, and the responsibility and safety requirements for trained fire-protection personnel. It covers the intended application, building elements, required thickness and seal distances, fire-resistance classes for walls and floors, applicable products and declarations of performance, design variants, and step-by-step installation.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/system-fsc-4-fire-resistant-penetration-sealing-system/500007/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/system-fsc-4-fire-resistant-penetration-sealing-system/500007.png","ImageObject",300,407,{"name":92,"@type":93},"Valentina","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-09","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is authorized to install the System FSC 4 penetration sealing system?","Question",{"text":112,"@type":113},"Installation is intended solely for personnel trained in fire protection. The document also directs installers to consult safety information for the specific penetration seal components.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which standards and assessment basis are referenced for System FSC 4?",{"text":117,"@type":113},"Usability is assessed in accordance with ETA 15/0907, covering reaction to fire, resistance to fire, release of dangerous substances, and durability/serviceability. Maximum fire resistance class EI 240 U/C applies per EN 13501-2.",{"name":119,"@type":110,"acceptedAnswer":120},"What key safety measures apply during installation on floors?",{"text":121,"@type":113},"The area below the floor penetration seal must be cordoned off against entry during work to prevent exposure to possible falling objects. Floor-seal contractors must inform clients in writing that the installed seals must be secured on site against loads, especially being walked on, using suitable measures.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},500007,1791656903,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},13056703020460,"https://ap-avatar.wpscdn.com/avatar/be000253dac470eee5d?_k=1778207105932848923","Installation instructions  \nSystem FSC 4  \nPenetration sealing system for pipes  \nFire resistant penetration sealing system for plastic pipes up to medium diameters in accordance with ETA-15/0907 . Maximum fire resistance class EI 240 U/C in accordance with EN 13501-2.  \nFlamro Brandschutz-Systeme GmbH • Am Sportplatz 2 • 56291 Leiningen • Germany T +49 6746 9410-0 • F +49 6746 9410-10 • [www.flamro.de](www.flamro.de) • [info@flamro.de](info@flamro.de)  \n© Copyright Flamro Brandschutz-Systeme GmbH, Leiningen. FLAMRO® ist eine Marke der Flamro Brandschutz-Systeme GmbH.  \nInstallation instructions Rev.: 23.12 1 of 11  \nInstallation instructions   \nSystem FSC 4  \nTable of contents  \nTopic  \nPage  \n1. Preliminary remarks / Overview....................................................................................................................................................3  \n1.1 Target group .....................................................................................................................................................................................3  \n1.2 Use of the instructions......................................................................................................................................................................3  \n1.3 Safety instructions ............................................................................................................................................................................3  \n1.4 Field of application ...........................................................................................................................................................................4  \n1.5 Building elements .............................................................................................................................................................................5  \n1.6 Thicknesses / penetration seal distances ........................................................................................................................................6  \n2. Fire resistance classes..................................................................................................................................................................7  \n2.1 Walls ................................................................................................................................................................................................7  \n2.2 Floors ...............................................................................................................................................................................................8  \n3. Products used ................................................................................................................................................................................9  \n3.1 Declarations of Performance............................................................................................................................................................9  \n4. Design variants ............................................................................................................................................................................ 10  \n4.1 Initial brackets (supports) ............................................................................................................................................................... 10  \n5. Installation steps.......................................................................................................................................................................... 11  \nInstallation instructions Rev.: 23.12 2 of 11  \nInstallation instructions   \nSystem FSC 4  \n1. Preliminary remarks / Overview  \n1.1 Target group  \nThe installation instructions are intended solely for personnel trained in fire protection.  \n1.2 Use of the instructions  \nBefore starting work, read through these installation instructions complet","cbCaijLpddJlHORL","https://ap.wps.com/l/cbCaijLpddJlHORL","pdf",1047417,11,"English","# Table of contents\n## 1. Preliminary remarks / Overview\n## 2. Fire resistance classes\n## 3. Products used\n## 4. Design variants\n## 5. Installation steps","[{\"question\":\"Who is authorized to install the System FSC 4 penetration sealing system?\",\"answer\":\"Installation is intended solely for personnel trained in fire protection. The document also directs installers to consult safety information for the specific penetration seal components.\"},{\"question\":\"Which standards and assessment basis are referenced for System FSC 4?\",\"answer\":\"Usability is assessed in accordance with ETA 15/0907, covering reaction to fire, resistance to fire, release of dangerous substances, and durability/serviceability. Maximum fire resistance class EI 240 U/C applies per EN 13501-2.\"},{\"question\":\"What key safety measures apply during installation on floors?\",\"answer\":\"The area below the floor penetration seal must be cordoned off against entry during work to prevent exposure to possible falling objects. Floor-seal contractors must inform clients in writing that the installed seals must be secured on site against loads, especially being walked on, using suitable measures.\"}]","System FSC 4 - Fire-resistant penetration sealing system | PDF",1791007953,28]