[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649791-105":59,"doc-detail-649791-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","swash-binti-architectural-and-structural-drawings-swash-facilities-drawing-set","SWASH BINTI - Architectural and Structural Drawings - Swash Facilities - Drawing Set","","Architectural and structural drawing package for the “Swash Facilities” under the project “Wezesha Binti Project” in Kigoma region. Includes floor plan, plumbing plan, plumbing and door schedules, window schedule, and detailed elevation views (side, rear, front) as well as sectional information. Engineering notes specify all dimensions in millimeters, foundation depth variations due to subsoil conditions, and scale guidance. Drawing pages are dated December 2024 and reference client, donor, and consulting/approval parties.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/swash-binti-architectural-and-structural-drawings-swash-facilities-drawing-set/649791/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/swash-binti-architectural-and-structural-drawings-swash-facilities-drawing-set/649791.png","ImageObject",300,407,{"name":92,"@type":93},"Aran","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-25","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What building type is specified in the drawing set?","Question",{"text":112,"@type":113},"The drawings specify the building type as “Girls Swash Building.”","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What unit system is used for dimensions in the general notes?",{"text":117,"@type":113},"The general note states that all dimensions are in millimeters (mm).",{"name":119,"@type":110,"acceptedAnswer":120},"How is foundation depth treated according to the notes?",{"text":121,"@type":113},"The notes indicate that foundation depth may change due to subsoil conditions.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649791,1792897994,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},137455076865,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","| WEZESHA BINTI PROJECT\u003Cbr>CONSTRUCTION OF GIRLS SWASH AT KIGOMA REGION |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| ARCHITECTURAL AND STRUCTURAL\u003Cbr>DRAWINGS\u003Cbr>SWASH FACILITIES\u003Cbr>CLIENT: DONOR: CONSULTANT |  |  |  |  |\n| | THE UNITED REPUBLIC OF TANZANIA PRESIDENT'S OFFICE REGIONAL ADMINISTRATION AND LOCAL GOVERNMENT KIGOMA REGION\u003Cbr>P.O BOX125\u003Cbr>[ras@kigoma](ras@kigoma .go.tz)[ .](ras@kigoma .go.tz)[go](ras@kigoma .go.tz)[.](ras@kigoma .go.tz)[tz](ras@kigoma .go.tz) | | WEZESHA BINTI PROJEC-T BELGIAN AGENCY FOR INTERNATIONAL COOPERATION\u003Cbr>P.O BOX24 KIGOMA TANZANIA | \u003Cbr>Peakey International Consulting Engineering Co . Ltd |\n\n\n| \u003Cbr> 3,535 \u003Cbr>\u003Cbr>1,500 220 1,680 500 500 750 500 750 500 750 500 750 500 850 1,200 450 1,500\u003Cbr>5,610\u003Cbr>3,030 500 574 1,000 505\u003Cbr>RAMP\u003Cbr>40\u003Cbr>D5\u003Cbr>Grill door to include 3mm thick metal at the middle part and wire\u003Cbr>1,500\u003Cbr>W2 W2 W2 W2 W2 W3\u003Cbr>2,730\u003Cbr>Changing Room\u003Cbr>1,950\u003Cbr>200\u003Cbr>D2\u003Cbr>1,730 800\u003Cbr>Handwashing Sink\u003Cbr>1,950\u003Cbr>WC WC WC WC WC\u003Cbr>150\u003Cbr>150150\u003Cbr>D2\u003Cbr>D2 D2 D2 D2 D2\u003Cbr>150\u003Cbr>800 450 800 450 800 450 760 490 800\u003Cbr>150\u003Cbr>500 1,000 900 800 450 800 450 800\u003Cbr>1,900 150\u003Cbr>1,560\u003Cbr>1,680\u003Cbr>5,610\u003Cbr>220\u003Cbr>40\u003Cbr>RAMP\u003Cbr>1,565 2,480\u003Cbr>5,610\u003Cbr>1 50 1 , 300 900\u003Cbr>Incinerator\u003Cbr>2,099 180\u003Cbr>W1\u003Cbr>2,000 150\u003Cbr>mesh at the bottom and top for security and privacy\u003Cbr> Vented wall above 1500mm Coping on perforated wall of the with 50mm overhang to prevent water ingress.\u003Cbr>750\u003Cbr>D5 D2 D2 D2\u003Cbr>WC-Disabled WC WC WC\u003Cbr>Handwashing Sink 2,100\u003Cbr>W3 W2 W2 W2\u003Cbr>1,500 220 1,680 700 1 , 200 700 500 750 500 750 500\u003Cbr>1,565\u003Cbr>Floor Plan\u003Cbr>IPS 13ø\u003Cbr>40\u003Cbr>MH\u003Cbr>MH\u003Cbr>MH\u003Cbr>MH MH MH MH MH\u003Cbr>GT GT\u003Cbr>WC WC WC WC WC\u003Cbr>Changing Room\u003Cbr>D2\u003Cbr>Incinerator\u003Cbr>WC-Disabled WC WC WC\u003Cbr>MH\u003Cbr>MH MH MH MH\u003Cbr>IPS 13ø\u003Cbr>GT\u003Cbr>GT\u003Cbr>Handwashing Sink Handwashing Sink\u003Cbr>40\u003Cbr>Plumbing Plan\u003Cbr>Sp\u003Cbr>Sk\u003Cbr>DOOR SCHEDULE No.\u003Cbr>01.\u003Cbr>   TYPE\u003Cbr>D2\u003Cbr>    SIZE   \u003Cbr>800/2100\u003Cbr>\u003Cbr>  No.  \u003Cbr>10 02. D5 1000/2100 DISABLED & INCINERATOR ROOMS\u003Cbr>02 TOTAL 12\u003Cbr>WINDOW SCHEDULE No.\u003Cbr>TYPE\u003Cbr>SIZE\u003Cbr>SILL HEIGTH\u003Cbr>LOCATION\u003Cbr>No. 01. 2000/2500 0000 CUBICLES & STORE  01 02.\u003Cbr>1900\u003Cbr>\u003Cbr>08 03. W3 1200/600 1900 CHANGING ROOM & DISABLED 02 TOTAL\u003Cbr>11 |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| | Kigoma MC | Client | REGIONAL COMMISSIONER'S OFFICE-KIGOMA | Consultant :\u003Cbr>| GENERAL NOTE: S | Drawing Title | SWASH BUILDING 01 |\n|  | Kigoma DC\u003Cbr>Kasulu TC |  |  |  | 1 . All dimensions are in mm\u003Cbr>2 . Depth of foundation may change due to subsoil condition\u003Cbr>3 . Scale : Not to scale | Date | DECEMBER, 2024 |\n|  |  | Supervisor | PEAKEY INTERNATIONAL CONSULTING ENGINEERING |  |  | Scale | 1 :85 |\n|  |  |  |  |  |  | Design by | ENABEL |\n|  | Kasulu DC |  |  |  |  |  |  |\n|  |  | Donor | WEZESHA BINTI ENABEL Belgian Development Agency P.O. Box 24 Kigoma , Tanzania |  |  | Checked by | PEAKEY INTERNATIONAL |\n|  | Kibondo DC |  |  |  |  |  |  |\n|  |  |  |  |  | BUILDING TYPE : GIRLS SWASH BUILDING. | Approved by | RE-RAS OFFICKIGOMA |\n\n| \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>SIDE ELEVATION\u003Cbr>SIDE ELEVATION\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>REAR ELEVATION |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| | Kigoma MC | Client | REGIONAL COMMISSIONER'S OFFICE-KIGOMA | Consultant :\u003Cbr>| GENERAL NOTE: S | Drawing Title | SWASH BUILDING 02 |\n|  |  |  |  |  | 1 . All dimensions are in mm\u003Cbr>2 . Depth of foundation may change due to subsoil condition\u003Cbr>3 . Scale : Not to scale | Date | DECEMBER, 2024 |\n|  | Kigoma DC |  |  |  |  |  |  |\n|  |  | Supervisor | PEAKEY INTERNATIONAL CONSULTING ENGINEERING |  |  | Scale | 1 :85 |\n|  | Kasulu TC |  |  |  |  |  |  |\n|  |  |  |  |  |  | Design by | ENABEL |\n|  | Kasulu DC |  |  |  |  |  |  |\n|  |  | Donor | WEZESHA BINTI ENABEL Belgian Development Agency P.O. Box 24 Kigoma , Tanzania |  |  | Checked by | PEAKEY INTERNATIONAL |\n|  | Kibondo DC |  |  |  |  |  |  |\n|  |  |  |  |  | BUILDING TYPE : GIRLS SWASH BUILDING. | Approved by | RE-RAS OFFICKIG","cbCaietOm63qji2L","https://ap.wps.com/l/cbCaietOm63qji2L","pdf",19174485,"English","# Architectural and Structural Drawings\n## SWASH Facilities\n## Floor Plan\n## Plumbing Plan\n## Door Schedule\n## Window Schedule\n## Side Elevation\n## Rear Elevation\n## Building Sections","[{\"question\":\"What building type is specified in the drawing set?\",\"answer\":\"The drawings specify the building type as “Girls Swash Building.”\"},{\"question\":\"What unit system is used for dimensions in the general notes?\",\"answer\":\"The general note states that all dimensions are in millimeters (mm).\"},{\"question\":\"How is foundation depth treated according to the notes?\",\"answer\":\"The notes indicate that foundation depth may change due to subsoil conditions.\"}]","SWASH BINTI - Architectural and Structural Drawings - Swash Facilities - Drawing Set | PDF",1792807237,15]