[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-561697-105":59,"doc-detail-561697-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","surge-arrester-ec600x-issue-07-datasheet","Surge arrester - EC600X - Issue 07 - Datasheet","","Technical datasheet for the EPCOS TDK Group surge arrester models B88069X0780S102 and the 2-electrode arrester EC600X (Series/Type EC600X, Issue 07, dated 2015-01-13). It lists key electrical specifications including DC spark-over voltage, impulse spark-over voltage distributions, service life current ratings, insulation resistance, capacitance, arc/glow transition behavior, weight, and operating temperatures. It also provides soldering parameters (wave soldering), dimensional/ordering and packing guidance, plus safety and handling cautions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/surge-arrester-ec600x-issue-07-datasheet/561697/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/surge-arrester-ec600x-issue-07-datasheet/561697.png","ImageObject",300,407,{"name":92,"@type":93},"Ben ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-21","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the main electrical limits for the surge arrester (EC600X)?","Question",{"text":112,"@type":113},"The datasheet specifies DC spark-over voltage with tolerance -10/+20% (min 540 V, max 720 V). It also provides impulse spark-over voltage values at 100 V/µs and 1 kV/µs for 99% of measured values and typical distribution values.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How is the service life of the surge arrester expressed?",{"text":117,"@type":113},"Service life is given as current-operation counts for different test conditions, including 10 operations at 50 Hz for 1 s, 1 operation at 50 Hz for 0.18 s (9 cycles), and multiple impulse standards (8/20 µs and 10/350 µs).",{"name":119,"@type":110,"acceptedAnswer":120},"What soldering and handling cautions are required?",{"text":121,"@type":113},"Wave soldering parameters include Pb-free assembly with solder composition Sn 95.5/Ag 3.8/Cu 0.7, bath temperature 263±3°C, and dwell time \u003C3 s. The cautions warn not to exceed the minimum spark-over voltage in power networks, to avoid burn risk from prolonged current stress, and to handle and not reuse damaged surge arresters.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},561697,1791886743,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},2336478951081,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Surge arrester  \n2-electrode arrester  \nSeries/Type: EC600X  \nOrdering code: B88069X0780S102  \nVersion/Date: Issue 07 / 2015-01-13  \n􀂤 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.  \nEPCOS AG is a TDK Group Company.  \nSurge arrester B88069X0780S102  \n2-electrode arrester EC600X  \nFeatures  \n􀂃 Standard size  \n􀂃 Very fast response time  \n􀂃 High current rating  \n􀂃 Stable performance over life  \n􀂃 Very low capacitance  \n􀂃 High insulation resistance  \n􀂃 RoHS-compatible  \nApplications  \n􀂃 Branch exchange  \n􀂃 Line protection  \n􀂃 Subscriber protection  \n􀂃 Alarm system  \n􀂃 Tuner  \n􀂃 Antenna protection  \nElectrical specifications  \n\n| DC spark-over voltage 1) 2) | 600 | V |\n| --- | --- | --- |\n| Tolerance | -10 / +20 | % |\n| Min. | 540 | V |\n| Max. | 720 | V |\n| Impulse spark-over voltage\u003Cbr>at 100 V/µs -for 99% of measured values | \u003C 1200 | V |\n| -typical values of distribution | \u003C 1000 | V |\n| at 1 kV/µs -for 99% of measured values | \u003C 1300 | V |\n| -typical values of distribution | \u003C 1100 | V |\n| Service life |  |  |\n| 10 operations 50 Hz, 1 s | 10 | A |\n| 1 operation 50 Hz, 0.18 s (9 cycles) | 65 | A |\n| 10 operations 8/20 µs | 5 | kA |\n| 1 operation 8/20 µs | 10 | kA |\n| 1 operation 10/350 µs | 1 | kA |\n| Insulation resistance at 100 VDC | > 10 | G􀀺 |\n| Capacitance at 1 MHz | \u003C 1.5 | pF |\n| Arc voltage at 1 A | ~ 12 | V |\n| Glow to arc transition current | \u003C 0.1 | A |\n| Glow voltage | ~ 60 | V |\n| Weight | ~ 1.5 | g |\n| Operation and storage temperature | 􀀐40 ... +90 | °C |\n| Climatic category (IEC 60068-1) | 40/ 90/ 21 |  |\n| Marking, red positive |  EC 600 YY O\u003Cbr>EC -Series\u003Cbr>600 -Nominal voltage YY -Year of production O -Non radioactive |  |\n| Certifications | UL 497B (E163070)\u003Cbr>UL 1449 (E319264) | |\n\n1)  \n2)  \nAt delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode  \nTerms in accordance with ITU-T Rec. K. 12; IEC 61663-2 and IEC 61643-311.  \nPPD AB PD / PPD AB PM Issue 07 / 2015-01-13  \n| Surge arrester |  | B88069X0780S102 |\n| --- | --- | --- |\n| 2-electrode arrester |  | EC600X |\n| Dimensional drawing in mm\u003Cbr>Ordering code and packing advice\u003Cbr>B88069X0780S102 = 100 pcs. on 5 taped stripes\u003Cbr>|  |  |\n| | |  |\n| PPD AB PD / PPD AB PM Issue 07 / 2015-01-13 |  |  |\n\nPlease read Cautionsand warningsand Page 3 of 5  \nImportant notes atthe end ofthis document.  \nSurge arrester B88069X0780S102  \n2-electrode arrester EC600X  \nSoldering parameter  \nWave soldering  \n| Wave profile features | Pb-free assembly |\n| --- | --- |\n| Solder | Sn 95.5 / Ag 3.8 / Cu 0.7 |\n| Solder bath temperature | 263 (±3) °C |\n| Dwell time | \u003C 3 s |\n\nSoldering profile applied to a single soldering process.  \nCautions and warnings  \n􀂃 Do not operate surge arresters in power supply networks, whose maximum operating voltage exceeds the minimum spark-over voltage of the surge arresters.  \n􀂃 Surge arresters may become hot in the event of longer periods of current stress (burn risk) . In the event of overload the connectors may fail or the component may be destroyed.  \n􀂃 If the contacts of the surge arresters are defective, current load can cause sparks and loud noises.  \n􀂃 Surge arresters must be handled with care and must not be dropped.  \n􀂃 Do not continue to use damaged surge arresters.  \nDisplay of ordering codes for EPCOS products  \nThe ordering code for one and the same EPCOS product can be represented differently in data sheets, data books, other publications, on the EPCOS website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under [www.epcos.com/orderingcodes](www.epcos.com/orderingcodes)  \nPPD AB PD / PPD AB PM Issue 07 / 2015-01-13  \nPlease read Cautionsand ","cbCaiqLta6VlOG0A","https://ap.wps.com/l/cbCaiqLta6VlOG0A","pdf",108205,"English","# Electrical specifications\n## DC spark-over voltage\n## Impulse spark-over voltage\n## Service life and ratings\n## Insulation resistance and capacitance\n# Soldering parameter\n## Wave soldering\n## Cautions and warnings","[{\"question\":\"What are the main electrical limits for the surge arrester (EC600X)?\",\"answer\":\"The datasheet specifies DC spark-over voltage with tolerance -10/+20% (min 540 V, max 720 V). It also provides impulse spark-over voltage values at 100 V/µs and 1 kV/µs for 99% of measured values and typical distribution values.\"},{\"question\":\"How is the service life of the surge arrester expressed?\",\"answer\":\"Service life is given as current-operation counts for different test conditions, including 10 operations at 50 Hz for 1 s, 1 operation at 50 Hz for 0.18 s (9 cycles), and multiple impulse standards (8/20 µs and 10/350 µs).\"},{\"question\":\"What soldering and handling cautions are required?\",\"answer\":\"Wave soldering parameters include Pb-free assembly with solder composition Sn 95.5/Ag 3.8/Cu 0.7, bath temperature 263±3°C, and dwell time \\u003c3 s. The cautions warn not to exceed the minimum spark-over voltage in power networks, to avoid burn risk from prolonged current stress, and to handle and not reuse damaged surge arresters.\"}]","Surge arrester - EC600X - Issue 07 - Datasheet | PDF",1791806648,13]