[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648348-105":59,"doc-detail-648348-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","sure-temp-chimney-catalog-technical-data-sheet-chimney-lengths","Sure-Temp Chimney Catalog - Technical Data Sheet - Chimney Lengths","","Sure-Temp SURE-TEMP chimney system information for USA use, including technical data sheet specifications and chimney lengths guidance. Covers applicable fuel types (wood, #2 oil, natural and LP gas), venting requirements for nonpositive internal pressure, UL 103 HT listing and temperature ratings, and required clearances to combustibles. Provides insulated chimney length options, twist-lock coupling approach, installation length calculation, and detailed size-to-part-number tables plus locking band details and adjustable-offset length notes.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/sure-temp-chimney-catalog-technical-data-sheet-chimney-lengths/648348/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/sure-temp-chimney-catalog-technical-data-sheet-chimney-lengths/648348.png","ImageObject",300,407,{"name":92,"@type":93},"Danger Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What fuel types and venting conditions does the Sure-Temp chimney system support?","Question",{"text":112,"@type":113},"It is intended for residential heating appliances burning wood, #2 oil, and natural and LP gas. It is designed for gravity (natural draft) and for nonpositive internal pressure venting only.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the key technical ratings and safety constraints listed in the document?",{"text":117,"@type":113},"The catalog references UL factory-built chimney standards and lists UL 103 HT. Temperature ratings are given as 2100°F (maximum test 10 min.), 1400°F (maximum for 60 min.), and 1000°F (maximum continuous operating). Clearance to combustibles is specified as 2\" of airspace for insulated lengths.",{"name":119,"@type":110,"acceptedAnswer":120},"How do you calculate the installed length of an insulated chimney section?",{"text":121,"@type":113},"To calculate installed length, subtract 1-1/4\" per joint. The document also states insulated chimneys require 2\" clearance to combustible material.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648348,1793005865,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962090769052,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Chimney Catalog  \nFUEL TYPE: GAS | OIL | WOOD USA ONLY  \nSURE-TEMP®  \nTABLE OF CONTENTS  \nTechnical Data Sheet ................................................................................................................ 3  \nChimney Lengths ....................................................................................................................4-5  \nElbows and Tees ....................................................................................................................6-9  \nSupports .............................................................................................................................9-13  \nChimney Kits ..................................................................................................................... 13-15  \nRound Tops............................................................................................................................ 16  \nFlashings........................................................................................................................... 17-19  \nShields..............................................................................................................................20-21  \nAdapters ............................................................................................................................... 22  \nAccessories .......................................................................................................................23-24  \nTypical Installations ............................................................................................................25-27  \n[2 Selkirk | www.selkirkcorp.com](2 Selkirk | www.selkirkcorp.com) (US)  \nSURE-TEMP®  \nSURE-TEMP® HT/SURE-TEMP®  \nTECHNICAL DATA SHEET  \n\n| IMPORTANT\u003Cbr>This catalog references Selkirk Chimney Systems with maximum test temperatures under Underwriters Laboratories Safety Standard for Factory-Built Chimneys.\u003Cbr>| Diameter Sizes: 5\", 6\", 7\" & 8\"\u003Cbr>Clearances: 2\" of Airspace to Combustibles\u003Cbr>Listing: UL 103 HT\u003Cbr>Temperature Ratings: 2100°F (Maximum Test 10 min.)\u003Cbr>1400°F (Maximum for 60 min.) 1000°F (Maximum Continuous Operating Temperatures) | 10\"\u003Cbr>2\" of Airspace to Combustibles UL 103\u003Cbr>1700°F (Maximum Test 10 min.) 1400°F (Maximum for 60 min.) 1000°F (Maximum Continuous Operating Temperatures) |\n| --- | --- | --- |\n\nThe Selkirk® Chimney System (SCS) is ideal for venting residential heating appliances burning wood, \\#2 oil, and natural and LP gas. It has been specifically designed for today’s modern, high-efficiency “airtight” wood stoves. It is designed for gravity (natural draft), nonpositive internal pressure venting only. The SCS is usable on any appliance having a power burner (such as an oil furnace) if that appliance operates with neutral or negative draft at its outlet. Non-residential appliances which may cause positive pressure in the chimney should use a Selkirk Commercial Model PS or IPS system.  \n800.992.8368 (US) | Selkirk 3  \nSURE-TEMP®  \nChimney Lengths  \nINSULATED LENGTHS  \n• Available in lengths of 6\", 12\", 18\", 24\", 36\" and 48\".  \n• Available in diameters of 5\", 6\", 7\", 8\", and10\".  \n• All insulated lengths are packaged with a Locking Band.  \n• Secure twist-lock design couples chimney sections together with just a 1/8 turn.  \n• To calculate installed length, subtract 1-1/4\" per joint.  \n• Insulated chimney requires 2\" clearance to combustible material.  \n\n| Size | A | B | C | Product Code | Part No. | Pack |\n| --- | --- | --- | --- | --- | --- | --- |\n| 6\" | 48\" | 6\" | 8\" | 206148 | 6ST-48 | 1 |\n| 7\" | 48\" | 7\" | 9\" | 207148 | 7ST-48 | 1 |\n| 8\" | 48\" | 8\" | 10\" | 208148 | 8ST-48 | 1 |\n|  |  |  |  |  |  |  |\n| 5\" | 36\" | 5\" | 7\" | 205036 | 5ST-36 | 1 |\n| 6\" | 36\" | 6\" | 8\" | 206036 | 6ST-36 | 1 |\n| 7\" | 36\" | 7\" | 9\" | 207036 | 7ST-36 | 1 |\n| 8\" | 36\" | 8\" | 10\" | 208036 | 8ST-36 | 1 |\n| 10\" | 36\" | 10\" | 12\" | 210036U | 10U-36 | 1 |\n|  |  |  |  |  |  |  |\n| 6\" | 24\" | 6\" | 8\" | 206024 | 6ST-24 | 1 |\n| 7\" | 24","cbCaij8E6LQQXM00","https://ap.wps.com/l/cbCaij8E6LQQXM00","pdf",4827497,32,"English","# Technical Data Sheet\n## Chimney Lengths\n## Insulated Lengths\n## Adjustable Lengths\n## Locking Band","[{\"question\":\"What fuel types and venting conditions does the Sure-Temp chimney system support?\",\"answer\":\"It is intended for residential heating appliances burning wood, #2 oil, and natural and LP gas. It is designed for gravity (natural draft) and for nonpositive internal pressure venting only.\"},{\"question\":\"What are the key technical ratings and safety constraints listed in the document?\",\"answer\":\"The catalog references UL factory-built chimney standards and lists UL 103 HT. Temperature ratings are given as 2100°F (maximum test 10 min.), 1400°F (maximum for 60 min.), and 1000°F (maximum continuous operating). Clearance to combustibles is specified as 2\\\" of airspace for insulated lengths.\"},{\"question\":\"How do you calculate the installed length of an insulated chimney section?\",\"answer\":\"To calculate installed length, subtract 1-1/4\\\" per joint. The document also states insulated chimneys require 2\\\" clearance to combustible material.\"}]","Sure-Temp Chimney Catalog - Technical Data Sheet - Chimney Lengths | PDF",1792793190,81]