[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664616-105":59,"doc-detail-664616-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","submission-requirement-guidelines-part-1-general","SUBMISSION REQUIREMENT GUIDELINES - Part 1 General","","Submission Requirement Guidelines define the University Plans Review Process and outline how designer schematic, design development, construction documents, estimates, and related submissions are reviewed and approved. The guidelines specify review stages, expected comment handling, and typical timelines. They also require drawing identification details, allowable sheet sizes, specification formatting and indexing, project manual contents, auxiliary material identification, and CAD submission requirements, with specific instructions for schematic design submissions and minimum submission data.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/submission-requirement-guidelines-part-1-general/664616/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/submission-requirement-guidelines-part-1-general/664616.png","ImageObject",300,407,{"name":92,"@type":93},"Grenda","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29",true,{"@type":101,"interactionType":102,"userInteractionCount":81},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is the University Plans Review Process and who manages it?","Question",{"text":111,"@type":112},"It is the process used to review and approve the Designer’s schematic, design development, and construction documents and estimates. It is handled by the University’s Project Manager, who distributes plans and specifications for departmental review and collects comments for consideration and discussion with the project team.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What minimum information must appear on drawings?",{"text":116,"@type":112},"All drawings must include, in the lower right-hand corner, the project name, SDSU project number, date (including current revision if any), quad, building number and address, and the appropriate drawing number and drawing identifications.",{"name":118,"@type":109,"acceptedAnswer":119},"When are CAD submissions required?",{"text":120,"@type":112},"CAD submittals are required for at least the 50% Construction Document, 100% Construction Document, and As-Built Record Drawing phases. They may not be required for other design phases, depending on direction from the Project Manager.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},664616,1793262713,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":142},7971474921005,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","SECTION 01 33 00  \nSUBMISSION REQUIREMENT GUIDELINES  \npart 1 GENERAL  \n1.1 Overview  \nA. University Plans Review Process:  \n1. The process by which the Designer’s schematic, design development, and construction documents and estimates are reviewed and approved is the University Plans Review Process. This occurs at or near the completion of each design phase and is handled by the University's Project Manager by distributing plans and specifications to the interested departments for review and comments. These comments, if any, are then transmitted to the Project Manager for consideration, response, and discussion with the Project Team prior to incorporation. The time required for this process will vary with the complexity of the project, but can ordinarily be expected to take two or three weeks for each stage. The number of sets of plans to be provided by the Designer is covered in the Owner/Architect or Owner/General Contractor Agreement.  \n2. The review stages are identified as follows:  \na. 100% Schematic Design submissions b. 100% Design Development submissions  \nc. 50% Construction Documents submissionsd. 100% Construction Documents submissions  \n3. The University Plans Review Process is the key administrative device used by staff to verify that the project is being designed in accordance with San Diego State University Facilities Design Guidelines. All deviations from these Guidelines shall be explicitly pointed out and discussed with the University's Project Manager prior to submittal for review, and that such deviations be approved in writing by the University's Project Team before incorporation into the project.  \nB. Presentation Format:  \n1. Drawings:  \na. All drawings must have the following minimum identification in the lower right hand corner: Project name, SDSU project number, date (including current revision, if any), quad, building number and address (provided by SDSU) and the appropriate drawing number and drawing identifications (i.e., first floor elevations, etc.) . The Designer may use a title block along the right hand margin, but the above minimum information must appear in the lower right hand corner of the sheet to aid in identification and retrieval of drawings from flat file cabinets.  \nb. The drawings shall be on the same size format, for each project. Maximum overall sheet size shall not exceed size E, 42 inch by 30 inch. Only standard, un-reduced sheet sizes D and E will be accepted, without prior approval of Project Manager.  \n2. Specifications shall follow the Construction Specifications Institute format and indexing.  \nThe first page of each of Divisions 15, 16, and 17 shall be an index to that section. Use dividers to separate specification sections at least as follows:  \na. Legal (Invitation to Bid, Instruction to Bidders, Proposal, Agreement, General Conditions, Addenda, Etc.)  \nb. Special Conditions, Construction  \nc. Administration Procedures  \nd. Architectural (Div. 1-14)  \ne. Mechanical (Div. 15)  \nf. Electrical (Div. 16)  \ng. Communication Services (Div. 17)  \n3. Note: at least one copy of the specifications shall be submitted in loose, unbound, unpunched format, for ease of reproduction.  \n4. CAD (Computer Aided Design) submissions: Unless otherwise directed by the Project Manager, a set of drawings for all applicable disciplines shall also be submitted in CAD form. CAD Submittals are required for at least the 50% Construction Document, 100% Construction Document, and As-Built Record Drawing phases, but may not be required for the other design phases (as determined by the Project Manager) .  \nC. Project Manual  \n1. The Project Manual serves as the repository of certain design submissions and other types of information about the project. The production of the Project Manual is the responsibility of the Designer. Sample information that should be included in the Project Manual is as follows:  \na. MEPS Basis of Design Narratives with load requirements and distribution plan  \nb. Soils Report","cbCaimygKrYdNola","https://ap.wps.com/l/cbCaimygKrYdNola","pdf",93261,"English","# SECTION 01 33 00\n## SUBMISSION REQUIREMENT GUIDELINES - part 1 GENERAL\n## 1.1 Overview\n### A. University Plans Review Process\n### B. Presentation Format\n### C. Project Manual\n### D. Auxiliary Materials\n## 1.2 Schematic Design Submissions\n### A. General\n### B. Minimum Submission Data","[{\"question\":\"What is the University Plans Review Process and who manages it?\",\"answer\":\"It is the process used to review and approve the Designer’s schematic, design development, and construction documents and estimates. It is handled by the University’s Project Manager, who distributes plans and specifications for departmental review and collects comments for consideration and discussion with the project team.\"},{\"question\":\"What minimum information must appear on drawings?\",\"answer\":\"All drawings must include, in the lower right-hand corner, the project name, SDSU project number, date (including current revision if any), quad, building number and address, and the appropriate drawing number and drawing identifications.\"},{\"question\":\"When are CAD submissions required?\",\"answer\":\"CAD submittals are required for at least the 50% Construction Document, 100% Construction Document, and As-Built Record Drawing phases. They may not be required for other design phases, depending on direction from the Project Manager.\"}]","SUBMISSION REQUIREMENT GUIDELINES - Part 1 General | PDF",23]