[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650996-105":59,"doc-detail-650996-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","structural-analysis-and-design-of-pump-house-pump-house-structural-design","STRUCTURAL ANALYSIS AND DESIGN OF PUMP HOUSE -  Pump House Structural Design","","The project’s objective is to analyze and design a Lift Irrigation Scheme Pump House structure using STAAD.Pro. Structural modeling is performed with manual load calculations and frame analysis under the LSM limit state method, aligned with IS code practices. The work includes soil investigation for foundation selection, analysis/design of a 38.520 m × 21.040 m RCC pump house comprising MCC, switchgear room, and pipe gallery. Components in contact with water use working stress method, while superstructure RC members follow IS:456-2000 limit state design.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/structural-analysis-and-design-of-pump-house-pump-house-structural-design/650996/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/structural-analysis-and-design-of-pump-house-pump-house-structural-design/650996.png","ImageObject",300,407,{"name":92,"@type":93},"Sarah ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the main objective of the pump house project?","Question",{"text":112,"@type":113},"The main objective is to analyze and design a Lift Irrigation Scheme Pump House structure using STAAD.Pro, including foundation-related considerations and structural member design.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which software and design methods are used?",{"text":117,"@type":113},"STAAD.Pro V8i is used for frame analysis. Water-contact components are designed using the working stress method, while RC superstructure members are designed using the limit state method as per IS:456-2000.",{"name":119,"@type":110,"acceptedAnswer":120},"What loads are considered in the structural design?",{"text":121,"@type":113},"The design considers dead loads, live loads, earthquake load, soil pressure, wind load, water load, and operating load. These loads guide slab, beam, column, and footing design.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650996,1792856032,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},962085320529,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","STRUCTURAL ANALYSIS AND DESIGN OF PUMP  \nHOUSE  \nMakani Alleiah  \nMaster of Technology in Structural Engineering,  \nAudisankara College of Engineering and Technology (Autonomous),  \nGudur, S.P.S.R Nellore, A.P, India.  \nY. Sreekanth  \nAssistant professor, Dept. of Civil Engineering  \nAudisankara College of Engineering and Technology (Autonomous),  \nGudur, S.P.S.R Nellore, A.P, India.  \nAbstract: The main objective of the project is to analyze and design a lift irrigation scheme structure-Pump House using [staad.pro. The](staad.pro. The) design of Pump House involves manual load calculations and the whole structure is analyzed by [staad.pro. LSM limit](staad.pro. LSM limit) state method is used in [staad.pro](staad.pro)[ ](staad.pro)[analysis conforming to IS-code of practice](analysis conforming to IS-code of practice). This project covers the Primary investigation of soil strata and the geotechnical properties of soil to choose the type of foundation and then the Analysis and design of a LIS Pump house 38.520M X 21.040M that include MCC building motor control center, switch gear room, pipe galley done by STAAD.PRO. All the components which are in contact with water are designed in working stress method and, the superstructure RC members are designed as per limit state method of design as per IS: 456-2000.The analysis and design of the Pump house is carried out by software STAAD.PRO V8i. In order to design, it is important to obtain the GAD general arrangement drawings of the particular structure that is positioning of the particular components. The different types of loads consider in this design are DEAD LOAD, LIVE LOAD, EARTHQUAKELOAD, SOILPRESSURE, WINDLOAD, WATER LOAD, OPERATING LOAD. Once the loads are obtained, the components take the load first i.e. the slab can be designed. Designing of slab depends upon whether it isone way or two-way slab. Then the beams and columns as well as footings will be designed. The frame analysis is done by STAAD.PRO.  \nKey words: Pump house, working stress method, limit state method, STAAD. Pro V8i, Earthquake analysis.  \nI. INTRODUCTION  \nThe project comprises of design of Pump House using STAAD.Pro. Structural design is the primary aspect of civil engineering. The very basis of construction of any Pump houses, residential house or dams, bridges, culverts, canals etc. is designing. Structural engineering has existed since humans first started to construct their own structures. The foremost basic in structural engineering is the design of simple basic components and members of a Pump house viz., Slabs, Beams, Columns, Wall and Footings. In order to design them, it is important to first obtain the general arrangement drawing of the particular structure that is, positioning of the particular Pumps (control panel room, office room, battery room, store room, outlet pipe, suction and delivery pipes etc.) such that they serve their respective purpose and also suiting to the requirement and comfort of the inhabitants. Thereby depending on the suitability; plan layout of beams and the position of columns are fixed. Thereafter, the loads are calculated namely the dead loads, which depend on the unit weight of the materials used (concrete, brick) and the live loads, which according to the code IS: 875-1987 is around 2 kN/m2. Once the loads are obtained, the component takes the load first i.e. the slabs can be designed. Designing of slabs depends upon whether it is a one-way or a two-way slab, the end conditions and the loading. From the slabs, the loads are transferred to the beam. The loads coming from the slabs onto the beam may be trapezoidal or triangular. Depending on this, the beam may be designed. Thereafter, the loads (mainly shear) from the beams are taken by the columns. For designing columns, it is necessary to know the moments they are subjected to. For this purpose, frame analysis is done by STAAD PRO SOFTWARE. Later, the footings are designed  \nbased on the loading from the column and ","cbCailmWsWMOdMxT","https://ap.wps.com/l/cbCailmWsWMOdMxT","pdf",1722717,"English","# Abstract\n# Introduction\n# Analysis and Design of Pump House\n## Properties\n## Building Parameters\n## Self Weights","[{\"question\":\"What is the main objective of the pump house project?\",\"answer\":\"The main objective is to analyze and design a Lift Irrigation Scheme Pump House structure using STAAD.Pro, including foundation-related considerations and structural member design.\"},{\"question\":\"Which software and design methods are used?\",\"answer\":\"STAAD.Pro V8i is used for frame analysis. Water-contact components are designed using the working stress method, while RC superstructure members are designed using the limit state method as per IS:456-2000.\"},{\"question\":\"What loads are considered in the structural design?\",\"answer\":\"The design considers dead loads, live loads, earthquake load, soil pressure, wind load, water load, and operating load. These loads guide slab, beam, column, and footing design.\"}]","STRUCTURAL ANALYSIS AND DESIGN OF PUMP HOUSE -  Pump House Structural Design | PDF",13]