[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-381263-105":59,"doc-detail-381263-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","stochastic-three-dimensional-numerical-phantoms-to-enable-computational-studies-in-quantitative-optoacoustic-computed-tomography-of-breast-cancer","Stochastic three-dimensional numerical phantoms to enable computational studies in quantitative optoacoustic computed tomography of breast cancer","","Quantitative optoacoustic computed tomography (OAT) system development for diagnostic breast cancer imaging faces barriers to objective evaluation via human trials due to cost and ethical constraints. This work proposes a virtual imaging trials framework that uses ensembles of digital breast phantoms, including numerical breast phantoms and numerical lesion phantoms, to capture clinically relevant anatomical variability and optoacoustic tissue property distributions. The paper releases 84 datasets and demonstrates the framework’s usefulness via a study on acoustic heterogeneity effects on breast OAT images.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/stochastic-three-dimensional-numerical-phantoms-to-enable-computational-studies-in-quantitative-optoacoustic-computed-tomography-of-breast-cancer/381263/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/stochastic-three-dimensional-numerical-phantoms-to-enable-computational-studies-in-quantitative-optoacoustic-computed-tomography-of-breast-cancer/381263.png","ImageObject",300,407,{"name":92,"@type":93},"Mia  ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-24","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Why are human trials infeasible for evaluating quantitative OAT system designs?","Question",{"text":113,"@type":114},"Objective assessments through human trials are not feasible because of cost and ethical concerns. The study motivates virtual imaging trials as an alternative.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What is the aim of the proposed framework?",{"text":118,"@type":114},"The framework aims to generate ensembles of realistic 3D anatomical, functional, optical, and acoustic numerical breast phantoms, as well as numerical lesion phantoms, for use in virtual imaging trials for breast cancer OAT.",{"name":120,"@type":111,"acceptedAnswer":121},"How are tumors represented in the numerical lesion phantoms (NLPs)?",{"text":122,"@type":114},"NLPs are modeled to include either viable tumor cells alone or a combination of viable tumor cells, a necrotic core, and a peripheral angiogenesis region.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},381263,1790736068,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},687207024478,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","RESEARCH PAPER  \nStochastic three-dimensional numerical phantomsto enable computational studies in quantitative optoacoustic computed tomography of  \nbreast cancer  \nSeonyeong Park,a Umberto Villa  ,b Fu Li,a Refik Mert Cam,c  \nAlexander A. Oraevsky  ,d and Mark A. Anastasioa,c,*  \naUniversity of Illinois Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States bThe University of Texas at Austin, Oden Institute for Computational Engineering and Sciences, Austin, Texas,  \nUnited States  \ncUniversity of Illinois Urbana-Champaign, Department of Electrical and Computer Engineering, Urbana, Illinois,  \nUnited States  \ndTomoWave Laboratories, Houston, Texas, United States  \nABSTRACT. Significance: When developing a new quantitative optoacoustic computed tomography (OAT) system for diagnostic imaging of breast cancer, objective assessments of various system designs through human trials are infeasible due to cost and ethical concerns. In prototype stages, however, different system designs can be costefficiently assessed via virtual imaging trials (VITs) employing ensembles of digital breast phantoms, i.e., numerical breast phantoms (NBPs), that convey clinically relevant variability in anatomy and optoacoustic tissue properties.  \nAim: The aim is to develop a framework for generating ensembles of realistic threedimensional (3D) anatomical, functional, optical, and acoustic NBPs and numerical lesion phantoms (NLPs) for use in VITs of OAT applications in the diagnostic imaging of breast cancer.  \nApproach: The generation of the anatomical NBPs was accomplished by extending existing NBPs developed by the U.S. Food and Drug Administration. As these were designed for use in mammography applications, substantial modifications were made to improve blood vasculature modeling for use in OAT. The NLPs were modeled to include viable tumor cells only or a combination of viable tumor cells, necrotic core, and peripheral angiogenesis region. Realistic optoacoustic tissue properties were stochastically assigned in the NBPs and NLPs.  \nResults: To advance optoacoustic and optical imaging research, 84 datasets have been released; these consist of anatomical, functional, optical, and acoustic NBPsand the corresponding simulated multi-wavelength optical fluence, initial pressure, and OAT measurements. The generated NBPs were compared with clinical data with respect to the volume of breast blood vessels and spatially averaged effective optical attenuation. The usefulness of the proposed framework was demonstrated through a case study to investigate the impact of acoustic heterogeneity on OAT images of the breast.  \nConclusions: The proposed framework will enhance the authenticity of virtual OAT studies and can be widely employed for the investigation and development of advanced image reconstruction and machine learning-based methods, as well asthe objective evaluation and optimization of the OAT system designs.  \n© The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.JBO.28.6.066002]  \n*Address all correspondence to Mark A. Anastasio, [maa@illinois.edu](maa@illinois.edu)  \nJournal of Biomedical Optics 066002-1 June 2023 • Vol. 28(6)  \nPark et al.: Stochastic three-dimensional numerical phantoms to enable    \nKeywords: Numerical breast phantoms; optical breast phantoms; acoustic breast phantoms; optoacoustic computed tomography; photoacoustic computed tomography; virtual imaging trials  \nPaper 230068GR received Mar. 17, 2023; revised May 18, 2023; accepted May 22, 2023; published Jun.  \n20, 2023 .  \n1 Introduction  \nOptoacoustic computed tomography (OAT), also known as photoacoustic computed tomography, is a non-invasive imaging modality being actively developed for clinical breast imaging and other biomedical applications.1–8 A unique featur","cbCaifw16MIrdvzD","https://ap.wps.com/l/cbCaifw16MIrdvzD","pdf",8842306,25,"English","# Introduction\n## Stochastic phantom framework and virtual imaging trials\n## Dataset release and phantom validation\n## Case study: acoustic heterogeneity impact\n## Conclusions","[{\"question\":\"Why are human trials infeasible for evaluating quantitative OAT system designs?\",\"answer\":\"Objective assessments through human trials are not feasible because of cost and ethical concerns. The study motivates virtual imaging trials as an alternative.\"},{\"question\":\"What is the aim of the proposed framework?\",\"answer\":\"The framework aims to generate ensembles of realistic 3D anatomical, functional, optical, and acoustic numerical breast phantoms, as well as numerical lesion phantoms, for use in virtual imaging trials for breast cancer OAT.\"},{\"question\":\"How are tumors represented in the numerical lesion phantoms (NLPs)?\",\"answer\":\"NLPs are modeled to include either viable tumor cells alone or a combination of viable tumor cells, a necrotic core, and a peripheral angiogenesis region.\"}]","Stochastic three-dimensional numerical phantoms to enable computational studies in quantitative optoacoustic computed tomography of breast cancer | PDF",1790244519,63,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/29003fa9385fed2b1f35b5a8107bd89c.webp",983,1272,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/07c50d43b05773f01054e1d23c68db8b.webp",982,1270,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ca4bd1b9d76b2848a2a120f2e45aedc9.webp",981,1269,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f3950349cdb720645bc6d89eddb2d574.webp",980,1268]