[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-505360-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-505360-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","stationary-engineer-cuny-exam-no-801-notice-of-examination","Stationary Engineer (CUNY) - Exam No. 801 - Notice of Examination","","Notice of Examination for the Stationary Engineer (CUNY) position, Exam No. 0801, for City University of New York applicants. Provides application window dates, application fee and card payment surcharge, and describes core job duties across HVAC and steam-power systems. Outlines special working conditions, salary minimum, qualification responsibilities, required licenses/certificates, English and identity proof requirements, and the online application process via OASys with submission deadlines and documentation guidance.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/exam/","Exam",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/stationary-engineer-cuny-exam-no-801-notice-of-examination/505360/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/stationary-engineer-cuny-exam-no-801-notice-of-examination/505360.png","ImageObject",300,407,{"name":42,"@type":43},"McGucket","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-10","2026-10-04",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",13,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What are the application dates for Exam No. 0801?","Question",{"text":63,"@type":64},"Applications are accepted from September 5, 2019 to September 25, 2019.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What qualifications and licenses/certificates are required?",{"text":68,"@type":64},"Applicants must have a High Pressure Boiler Operating Engineer license, a Refrigerating System Operating Engineer Certificate (Q-01), and an EPA 608 Universal Chlorofluorocarbon (CFC) certificate by the last day of the application period, and must complete required test sections using those details.",{"name":70,"@type":61,"acceptedAnswer":71},"How do applicants submit an application and payment?",{"text":72,"@type":64},"Applicants who meet the qualification requirements apply online through the Online Application System (OASys), submit the application and payment electronically, and provide a unique valid email address.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},505360,1791506685,{"code":4,"msg":82,"data":83},"success",[84,88,92,95,100,105,110,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":93,"slug":94},70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":112,"show_sort_weight":113,"slug":114},8,"Research & Report",30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":96,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":33,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":33,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":124,"preview_page_count":4},1236954412713,"https://us-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","BILL DE BLASIO Mayor  \nLISETTE CAMILO Commissioner  \nDEPARTMENT OF CITYWIDE ADMINISTRATIVE SERVICES BUREAU OF EXAMINATIONS  \nNOTICE OF EXAMINATION  \nSTATIONARY ENGINEER (CUNY)  \nExam No. 0801  \n(For The City University of New York Only)  \nWHEN TO APPLY: From: September 5, 2019  \nTo: September 25, 2019  \nAPPLICATION FEE: $101.00  \nIf you choose to pay the application fee with a credit/debit/gift card, you will be charged a fee of 2.00% of the payment amount. This fee is nonrefundable.  \nYOU ARE RESPONSIBLE FOR READING THIS ENTIRE NOTICE  \nBEFORE YOU SUBMIT YOUR APPLICATION.  \nWHAT THE JOB INVOLVES:  \nStationary Engineers (CUNY), under general supervision, are responsible for the operation, maintenance, adjustment, testing, and repair of steam power plant, air conditioning, chiller plant, fire protection systems, electro-mechanical building equipment, and related auxiliary systems in public buildings. They operate, maintain, repair, and adjust manual and automatic gas and oil fired boilers, furnaces, steam reducing stations, engines, turbines, pumps, valves, heat exchangers, generators, motors, water treatment systems, cooling towers, condensers, evaporators, emergency generators, and associated equipment for heating, ventilating, air conditioning, and lighting in public buildings; perform periodic inspections of equipment and repairs of such equipment; schedule, perform, and may oversee preventative maintenance; direct the work of oilers, high pressure plant tenders, and other subordinate personnel assigned to HVAC plant operation; take responsible charge of a watch and while so engaged supervise and direct subordinate personnel; address emergency repairs as required; operate control consoles in control rooms for building maintenance and building automation systems; adjust HVAC systems water chemistry through testing, treatment, retesting, and recording of readings; prepare requisitions for materials and spare parts in accordance with College procedures; orient, train, and monitor subordinates and other personnel on plant operations and job related safety; read meters, gauges, and other recording devices and log the data; prepare and maintain records and writes reports of both technical and informational nature regarding HVAC maintenance and repair. All Stationary Engineers (CUNY) perform related work.  \nSpecial Working Conditions:  \nStationary Engineers (CUNY) may be required to work various shifts including nights, Saturdays, Sundays, and holidays.  \nSome of the physical activities performed by Stationary Engineers (CUNY) and environmental conditions experienced are: working in confined areas in a physical plant, including a boiler room, heating room, and/or ventilating room; walking up and down stairs; climbing up and down ladders; handling chemicals; and being around hazardous materials, such as asbestos and infectious waste.  \n(This is a brief description of what you might do in this position and does not include all the duties of this position.)  \nTHE SALARY:  \nThe current minimum salary is $60.84 per hour, for a 40 hour work week. This rate is subject to change.  \nHOW TO QUALIFY:  \nYou are responsible for determining whether or not you meet the qualification requirements for this examination prior to submitting your application. If you are marked \"Not Qualified,\" your application fee will not be refunded and you will not receive a score.  \nLicense/Certificate Requirements: By the last day of the application period, you must possess:  \n1. A valid license for High Pressure Boiler Operating Engineer issued by the New York City Department of Buildings; and  \n2. A valid Certificate of Qualification for Refrigerating System Operating Engineer (Q-01) issued by the New York City Fire Department; and  \n3. A valid Universal Chlorofluorocarbon (CFC) Certificate (EPA 608 Certificate) for handling refrigerants issued by the United States Environmental Protection Agency.  \nYou must complete all parts of the Education and Experience Te","cbCaiqwT8LQLJqU5","https://ap.wps.com/l/cbCaiqwT8LQLJqU5","pdf",249710,"English","# WHEN TO APPLY\n# WHAT THE JOB INVOLVES\n## Special Working Conditions\n# THE SALARY\n# HOW TO QUALIFY\n## License/Certificate Requirements\n# READ CAREFULLY AND SAVE FOR FUTURE REFERENCE\n# HOW TO APPLY","[{\"question\":\"What are the application dates for Exam No. 0801?\",\"answer\":\"Applications are accepted from September 5, 2019 to September 25, 2019.\"},{\"question\":\"What qualifications and licenses/certificates are required?\",\"answer\":\"Applicants must have a High Pressure Boiler Operating Engineer license, a Refrigerating System Operating Engineer Certificate (Q-01), and an EPA 608 Universal Chlorofluorocarbon (CFC) certificate by the last day of the application period, and must complete required test sections using those details.\"},{\"question\":\"How do applicants submit an application and payment?\",\"answer\":\"Applicants who meet the qualification requirements apply online through the Online Application System (OASys), submit the application and payment electronically, and provide a unique valid email address.\"}]","Stationary Engineer (CUNY) - Exam No. 801 - Notice of Examination | PDF",1791145610]