[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650182-105":59,"doc-detail-650182-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","standard-specifications-metal-building-systems","Standard Specifications - Metal Building Systems","","Standard Specifications for Metal Building Systems define requirements for metal building materials, fabrication, and erection under Sunward’s scope. The document outlines what constitutes a complete building system, identifies major structural frame types, and provides definitions for key building dimensions and terms. It also specifies applicable design standards, engineering practices, structural steel and joint requirements, bolt and welding methods, and code references used for model code compliance and load conditions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/standard-specifications-metal-building-systems/650182/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/standard-specifications-metal-building-systems/650182.png","ImageObject",300,407,{"name":92,"@type":93},"Indoniesian Boy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does the scope of these specifications cover for Sunward metal buildings?","Question",{"text":112,"@type":113},"The specifications cover the materials and fabrication of building materials manufactured by Sunward and require design and erection in accordance with the specifications and accompanying drawings.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What building types are described in the building description section?",{"text":117,"@type":113},"The document defines rigid frame, straight column frame, multi-span building, single slope, and leanto configurations, including basic structural characteristics and load considerations.",{"name":119,"@type":110,"acceptedAnswer":120},"Which standards, specifications, and codes are used for metal building design?",{"text":121,"@type":113},"The document references ASCE 7, MBMA manuals, AISC steel construction guidelines, AISC joint specifications using ASTM bolts, AISI cold-formed steel design, AWS welding standards, CSA standards, and model building codes such as IBC and NBC.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650182,1792876136,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":41},962090760608,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Page 1  \nof 12  \nStandard Specifications  \nMETAL BUILDING SYSTEMS  \nINDEX  \nSection 1: General  \nSection 2: Structural Design  \nSection 3: Basic Material Specifications  \nSection 4: Structural  \nSection 5: Roof and Wall Covering  \nSection 6: Miscellaneous Material Specifications  \nSection 7: Accessories  \nSection 8: Erection  \nSection 9: Anchorage and Foundations  \n SECTION 1: GENERAL   \n1.1 SCOPE  \n1.1.1 These specifications cover the materials and the fabrication of building materials manufactured by Sunward (“The Company”) , which shall be designed and erected in accordance with these specifications and accompanying drawings supplied with building materials. Erection by others.  \n1.1.2 The material furnished shall include the structural framing, roof panels, wall panels, bracing, fasteners, sealants, flashing, and all other parts for a complete building system (except anchor boltsand all items imbedded in the concrete. ) Overhead doors, insulation, etc. , are not considered part of the building system and should be supplied by others.  \n1.2 BUILDING DESCRIPTION  \n1.2.1 RIGID FRAME: A structural frame consisting of members joined together with moment connections so as to render the frame stable with respect to the design load, without the need for bracing in its plane. The columns are typically tapered.  \n1.2.2 STRAIGHT COLUMN FRAME: They are identical to the Rigid frame as defined in section 1.2.1 except the columns are straight, not tapered.  \n1.2.3 MULTI-SPAN BUILDING: Buildings consisting of more than one span across the width of the building. Multi-span is a rigid frame as defined in section 1.2.1.  \nSunward Specifications Revised: 4/ 13/21  \nPage 2 of 12  \n1.2.4 SINGLE SLOPE: Rigid frame is continuous transverse frame building with a roof that slopes in one direction. Can be clear span or multi-span.  \n1.2.5 LEAN-TO: A building extension with a roof that slopes in one direction, getting support from the structure to which it attaches. Main structure must be designed to handle extra load of leanto.  \n1.3 BUILDING TERMINOLOGY  \n1.3.1 BUILDING WIDTH: The dimension of the building measured parallel to the main framing from sidewall to sidewall, outside of by-pass or flush mounted girts.  \n1.3.2 BUILDING EAVE HEIGHT: is a nominal dimension measured from bottom of the column base plate to the intersection of the roof and sidewall sheets at the eave strut.  \n1.3.3 BUILDING LENGTH: The dimension of the building measured perpendicular to the main framing from endwall to endwall, outside of by-pass or flush mounted girts.  \n1.3.4 BAY: The space between the main frames measured normal to the frame.  \n1.3.5 ROOF SLOPE: The tangent of the angle that a roof surface makes with the horizontal, usually expressed in units of vertical rise to 12 units of horizontal run.  \n1.4 DRAWINGS AND CERTIFICATION  \n1.4.1 The Company shall furnish approval erection drawings which include anchor bolts plans, wall and roof elevations for framing and sheeting, frame cross sections and general details to show clearly the proper assembly for all building components. Final erection drawings and shipping list are delivered with the building, and these drawings are to be used to erect the building.  \n1.4.2 A qualified professional engineer shall certify that the building design meets the requirements of the specifications and conforms to good engineering practices for the loading conditions requested.  \n1.4.3 Engineer letter of certification and engineer stamped drawings supplied for each job.  \n1.4.4 CERTIFICATIONS: The Company is an approved fabricator with the following certifications:  \nIAS AC472, CSA A660, CSA W47 . 1, City of Houston, City of Los Angeles: Type I Fabricator, Miami Dade County, Clark County Nevada  \nSunward Specifications Revised: 4/ 13/21  \nPage 3 of 12  \n SECTION 2: DESIGN   \n2.1 DESIGN STANDARDS, SPECIFICATIONS AND CODES  \nThe following standards, specifications and codes are used in designing metal buildings at the Company.  \n2.1.1 ","cbCaihRvAVc2GXe6","https://ap.wps.com/l/cbCaihRvAVc2GXe6","pdf",1122858,12,"English","# Section 1: General\n## 1.1 Scope\n## 1.2 Building Description\n## 1.3 Building Terminology\n## 1.4 Drawings and Certification\n# Section 2: Design\n## 2.1 Design Standards, Specifications and Codes","[{\"question\":\"What does the scope of these specifications cover for Sunward metal buildings?\",\"answer\":\"The specifications cover the materials and fabrication of building materials manufactured by Sunward and require design and erection in accordance with the specifications and accompanying drawings.\"},{\"question\":\"What building types are described in the building description section?\",\"answer\":\"The document defines rigid frame, straight column frame, multi-span building, single slope, and leanto configurations, including basic structural characteristics and load considerations.\"},{\"question\":\"Which standards, specifications, and codes are used for metal building design?\",\"answer\":\"The document references ASCE 7, MBMA manuals, AISC steel construction guidelines, AISC joint specifications using ASTM bolts, AISI cold-formed steel design, AWS welding standards, CSA standards, and model building codes such as IBC and NBC.\"}]","Standard Specifications - Metal Building Systems | PDF",1792820715]