[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663774-105":59,"doc-detail-663774-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","standard-drawings-sewers","STANDARD DRAWINGS - SEWERS","","Standard drawings and detailed sewer construction references covering sanitary sewer systems and associated utility water line protection. Includes a table of pages/drawings such as utility line protection from gravity sewers, precast and grade-adjustment manholes, saddle and lateral connection details, backwater valve and cleanout arrangements, pipe bedding and encasement, and building sewer installation in open/closed gravity systems. Provides plan notes, revisions, approval references, and manhole technical requirements for materials, mortar, anchoring, curing, and installation controls.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/standard-drawings-sewers/663774/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/standard-drawings-sewers/663774.png","ImageObject",300,407,{"name":92,"@type":93},"percent12345","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What drawings are included in this standard sewer drawing set?","Question",{"text":112,"@type":113},"The table of contents lists multiple sewer-related drawings including utility water line protection, precast and grade-adjustment manholes, manhole frame and cover, sewer lateral details, cleanouts, backwater valves, and building sewer installations for open and closed systems.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How are utility water lines protected in areas with gravity sewers?",{"text":117,"@type":113},"The set includes a dedicated drawing for protection of utility water lines from gravity sewers, along with related parallel-crossing and easement considerations described in the referenced drawings and notes.",{"name":119,"@type":110,"acceptedAnswer":120},"What installation requirements are specified for manhole sections in paved and easement areas?",{"text":121,"@type":113},"The manhole section notes specify forming and pouring a concrete base, washing and setting sections in 1:3 mortar, concrete strength requirements, anchoring frames to concrete sections using approved epoxy materials, curing and cleaning steps, and minimum coating thickness where applicable.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663774,1793231609,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},1099529851338,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","# STANDARD DRAWINGS FORSANITARY SEWERS\n\nSPECIAL DISTRICTS DEPARTMENTWATER AND SANITATION DIVISIONENGINEERING AND CONSTRUCTION DIVISION  \n# TABLE OF CONTENTSDIVISION“E”STANDARD DRAWINGSSEWERS\n\nPage/Drawing  \nE-1 Protection of Utility Water Lines from Gravity Sewers  \nE-2  \nPre-cast Manhole  \nE-3  \nManhole Adjustment to Grade  \nE-3A  \nPre-cast Manhole Unpaved Area  \nDrop Manhole  \nE-4  \nManhole Frame and Cover  \nE-5  \nE-6  \nPre-cast Concrete Shallow Manhole  \nSaddle Installation Detail  \nE-7  \nE-8  \nTap for A.C.P.or V.C.P.Pipe  \nE-9  \nSewer Lateral Non-curbed Streets,Type A,B,and C  \nSewer Lateral Curbed Streets  \nE-10  \nChimney and Deep Lateral  \nE-11  \nBuilding Lateral  \nE-12  \nLateral Connection Adjacent to Waterways  \nE-13  \nE-14 Sewer Main End of Line Cleanout  \nE-15 Backwater Valve Detail“A”  \nE-16 Cutoff Wall for Mountain Slopes  \nE-17 Concrete Blanket for Sewer Lateral Crossing Under Water Course or Crossing  \nE-18 Pipe Bedding  \nE-19 Building Sewer or Lateral Parallel With Water Course  \nE-20 BackfillStabilizer and Concrete Blanket  \nErosion Control,Building &On-Site Sewers  \nE-21  \nE-22  \nBuilding Sewer Installation,Open System Gravity,CSD,CSA 79&53B  \nE-23 Building Sewer Detail,Open System Gravity  \nE-23B Building Sewer Installation Details,Closed System Gravity  \nE-24 Building Sewer Installation,Closed System Gravity  \nE-25 Elevated Stream Crossing Plan  \nE-26  \nConcrete Encasement  \nE-27 Camp Site Sewer and Utility Connection  \n\n| 14”  \u003Cbr>PARALLEL  \u003Cbr>CROSSING  \u003Cbr>SANITARY SEWERS AND  \u003Cbr>SANITARY SEWERS AND  \u003Cbr>UTILITY WATER LINES  \u003Cbr>UTILITY WATER LINES   |  |  |  |  |\n| --- | --- | --- | --- | --- |\n|  |  |  |  |  |\n| ZONE “P”   | WATER MAIN CONSTRUCTION IN THIS ZONE IS PROHIBITED.   |  |  |  |\n| ZONE “A”   | NO WATER MAINS SHALL BE CONSTRUCTED IN THIS ZONE WITHOUT  \u003Cbr>APPROVAL FROM THE HEALTH AGENCY.   |  |  |  |\n| ZONE “B”   | WATER MAINS IN THIS ZONE SHALL BE CONSTRUCTED OF SPECIAL  \u003Cbr>PIPE AS LISTED BELOW.   |  |  |  |\n| ZONE”C”   | WATER MAINS SHALL HAVE NO JOINTS WITHIN ZONE ”C”AND SHALL  \u003Cbr>BE CONSTRUCTED OF SPECIAL PIPE AS LISTED BELOW.   |  |  |  |\n| ZONE“D”   | WATER MAINS SHALL HAVE NO JOINTS WITHIN ZONE ”D”AND SHALL  \u003Cbr>BE CONSTRUCTED OF SPECIAL PIPE AS LISTED BELOW.   |  |  |  |\n| SPECIAL PIPE ALTERNATIVES:  \u003Cbr>1.    DUCTILE IRON PIPE WITH HOT DIP BITMINOUS COATING.  \u003Cbr>2.  \u003Cbr>DIPPED AND WRAPPED ONE-FOURTH INCH THICK WELDED STEEL  \u003Cbr>PIPE.  \u003Cbr>3.  CLASS 200 PRESSURE RATED PLASTIC WATER PIPE(DR 14 PER  \u003Cbr>AWWA C900)OR EQUIVALENT.  \u003Cbr>4.  \u003Cbr>REINFORCED CONCRETE PRESSURE PIPE,STEEL CYLINDER  \u003Cbr>TYPE,PER AWWA(C300-74 OR C301-79 OR C303-70).   |  |  |  |  |\n|  |  | REVISIONS   | PROTECTION OF UTILITY WATER  \u003Cbr>LINES FROM GRAVITY SEWERS   | DRAWING  \u003Cbr>NUMBER  \u003Cbr>E-1   |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  | Approved:  \u003Cbr>Date:1271Z  \u003Cbr>ew  \u003Cbr>1   |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n\nDETAIL FOR MANHOLES IN PAVED AREAS一—DETAIL FOR MANHOLES IN EASEMENTS18\"MIN.  \nSEE NOTE \\#5 “MORTAR”ADJUST RINGSAS REQUIRED12”MINIMUM4”MAXIMUM20”MAXIMUM  \nSEE NOTE \\#4NOTES:          USE AS FEW SECTIONS ASPOSSIBLE TO REACH DESIREDHEIGHT  \n24\"MIN.36\"MAX.  \n1.  CONTRACTOR SHALL FORM ANDPOUR CONCRETE BASE WITH COVER6”ADJUSTED AS SHOWN.AFTER FINALPAVING OPERATION,ENTIRE DIRTEXCAVATION FOR FRAME ADJUSTMENTTO BE BACKFILLED WITH CLASS IV48 INCH DIAMETERCONCRETE.  \nVARIABLE  \n2.  ALL SECTIONS TO BE WASHED TOREMOVE ANY LOOSE MATERIAL ANDWHILE STILL WET,THEY ARE TO BESET IN 1:3 MORTAR,TRIMEDFLARE FROMSHELF SLOPE 1”IN 12”SMOOTH INSIDE AND OUTSIDE ATSPRINGLINETIME OF SETTING.INCLUDES FRAMESHELF.MINT9_GROOVE TO BE FORMEDEXCEPT AS IN NOTE \\#5.IN BASE OF MANHOLE  \n3.  CONCRETE FOR MANHOLE2”MINIMUMSECTIONS ARE 3000 PSI MINIMUM.(TO BOTTOM OF GROOVE)  \n4.  ON ALL EASEMENT MANHOLESCONTRACTOR SHALL ANCHOR FRAMESTO CONCRETE SECTIONS BY THE USE  \nVARIABLE  \nVARIABLEOF EPOXY,AMERICAN 3000 EPOXYBINDER PASTE OR EQUAL,SUPPLIEDBY HUB CONSTRUCTION SPECIALTIES  INVERT ELEVATION AS SHOWN ONINC.AS APPROVED BY THEPLANS.ENGINE","cbCaieKNV7tkY3l2","https://ap.wps.com/l/cbCaieKNV7tkY3l2","pdf",782684,31,"English","# TABLE OF CONTENTS\n## SEWERS - STANDARD DRAWINGS\n## Protection and Manhole Details\n## Sewer Lateral and Connection Details\n## Building Sewer Installation Plans\n## Water Main Prohibition Zones","[{\"question\":\"What drawings are included in this standard sewer drawing set?\",\"answer\":\"The table of contents lists multiple sewer-related drawings including utility water line protection, precast and grade-adjustment manholes, manhole frame and cover, sewer lateral details, cleanouts, backwater valves, and building sewer installations for open and closed systems.\"},{\"question\":\"How are utility water lines protected in areas with gravity sewers?\",\"answer\":\"The set includes a dedicated drawing for protection of utility water lines from gravity sewers, along with related parallel-crossing and easement considerations described in the referenced drawings and notes.\"},{\"question\":\"What installation requirements are specified for manhole sections in paved and easement areas?\",\"answer\":\"The manhole section notes specify forming and pouring a concrete base, washing and setting sections in 1:3 mortar, concrete strength requirements, anchoring frames to concrete sections using approved epoxy materials, curing and cleaning steps, and minimum coating thickness where applicable.\"}]","STANDARD DRAWINGS - SEWERS | PDF",78]