[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663124-105":59,"doc-detail-663124-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","standard-drawing-type-2-test-point-installation-connection-details","STANDARD DRAWING - TYPE 2 TEST POINT - Installation & Connection Details","","Standard drawing type 2 test point installation and connection details for a cathodic protection system. Provides front elevation and face plate, face plate layout, and enclosure connection schematic references with N.T.S scale notes and bill of materials for the test point head, including gasket, upstand, cable, and mounting hardware. Includes fabrication and general installation requirements for threads cleaning, cable slack, handling to avoid marks, painting exposed threads, earthing attachment guidance, and reference electrode stabilization and installation instructions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/standard-drawing-type-2-test-point-installation-connection-details/663124/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/standard-drawing-type-2-test-point-installation-connection-details/663124.png","ImageObject",300,407,{"name":92,"@type":93},"miraaa_2004","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What components are specified in the type 2 test point head bill of materials?","Question",{"text":112,"@type":113},"The document lists a face plate, neoprene gasket, test point upstand, flexible copper insulated cable, hex head bolt and washer, and crimp lugs, along with quantities for the assembly.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What general installation practices are required for the test point upstand and head threads?",{"text":117,"@type":113},"Threads on the test point upstand and head must be cleaned free of oil, grease, and dirt; the head is screwed down onto the upstand and positioned by the grub screw, then exposed pipe threads are painted with galvanising type paint.",{"name":119,"@type":110,"acceptedAnswer":120},"How is the reference electrode stabilized and installed?",{"text":121,"@type":113},"The reference electrode is stabilized zinc type per the cited standard, supplied with a 10 m tail; it is installed in the pipe trench as shown after preparing by removing protective packaging, soaking, and backfilling as directed.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663124,1793225236,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962094249165,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","\"DETAIL 2“  \nFRONT ELEVATION  \nFACE PLATE ONTTED FOR CLARTY  \n\"DETAIL3\"  \nFACE PLATE LAYOUT  \n\"DETAIL₁“  \nENCLOSURE CONNECTION SCHEMATIC  \n“DETAIL 4”  \nTYPICAL FACE PLATE  \n\n| REFER TO DRAWINGS D⁴101-010&D4101-011.  \u003Cbr>IEST POINT UPSTAND  \u003Cbr>TERMINATION ARRANGEMENT  \u003Cbr>SCALE:NTS  \u003Cbr>NSTALED AS SHOMN ON THS DRAMMG  \u003Cbr>64 SE DRAMING DL101-014-STRATHBLANE PLANT END  \u003Cbr>5CALE 19  \u003Cbr>SCALE:MT5.  \u003Cbr>RYS   |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| No.   | DATE   | REVISIONS   | DESIGN   | DRAWN   | CHK   | APP   | PROPRIETARY INFORMATION  \u003Cbr>THIS DRAWING AND ALL INFORMATION  \u003Cbr>SHOWN SHALL ONLY BE REPRODUCED  \u003Cbr>IN FLL AND ONLY MITH THE EXPRESS  \u003Cbr>PERMSSCN OF ANODEENGMERING PTY.LTD  \u003Cbr>OR AUTHORISED AGENT THERE0F.   | PROJECT   |  | POBOX4444_  \u003Cbr>LOGANHOLME DC,QLD 4129  \u003Cbr>Phone:61(Q)738015521  \u003Cbr>ww.anodeengineering.com   |  |  |\n|  |  |  |  |  |  |  |  | STANDARD DRAWING -TYPE 2 TEST POINT  \u003Cbr>CATHODIC PROTECTION SYSTEM   |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  | SCALE:   | N.T.S.   |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  | PROJECT  \u003Cbr>No.   | D4101   |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  | DRG No.   | D010-006   | REV  \u003Cbr>A   |\n| A   | 15-12-2006   | ISSUED F0R REVIEW   | WB   | AH   | SB   | WB   |  | TITLE  \u003Cbr>NSTALLATION &CONNECTION DETAILS   |  |  |  |  |\n\n\n|  | 1□   | FACE PLATE (SEE DETAIL)   | 1二   |\n| --- | --- | --- | --- |\n|  | 2   | 1.6mm THICK NEOPRENE GASKET   | 1   |\n|  | 3   | TEST POINT UPSTAND(SEE DETAIL)   | 1   |\n|  | 4   | 6mm²FLEXIBLE COPPER INSULATED CABLE   | 1m   |\n|  | 5   | M6x 20316 S/STEEL HEX HEAD BOLT AND WASHER   | 10   |\n|  | 6   | UTILUX CRIMP LUG 8 DIA.HOLE/6mm CABLE   | 6   |\n|  |  | UTILUX 1405A/100 CRIMP LUG   | 4   |\n|  |  | DESCRIPTION   | QTY   |\n|  | TEST POINT HEAD BILL OF MATERIALS(TYPE 2)   |  |  |\n| (1)TEST POI   | NT HEAD FABRICATION NOTES:   |  |  |\n\n(1.1)MATERIAL -GRAVITY DIE 〔AST ALUMINIUM CORROSION RESISTANT GRADE CC601.  \n(1.2)FIX GRUB SCREW INTO POSITION TO LOCK BOX ONTO UPSTAND (REFER TO DETAIL 2&SECTION 3B.  \n# (2)FACE PLATE FABRICATION NOTES:\n\n(2.1 MATERIAL-6mm THICK LEXAN POLY CARBONATE  \n(2.2)ALL LINEWORK AND PRINTING TO BE SILKSCREEN EPOXY ON INTERNAL FACE.WHITE BACKGROUNDWITH BLACK LETTERING AND LINEWORK  \n(2.3)FOR TYPE FS.CABLES TO THE FOREIGN STRUCTURE PIPE SHALL BE DENTIFED USING SUITABLECABLE IDENTIFICATION.  \n# (3)GENERAL NOTES:\n\n3.1.THE THREADS ON THE TEST POINT UPSTAND AND N THE TEST POINT HEAD SHALL BE CLEANEDFREE OF OIL,GREASE AND DIRT.THE HEAD SHALL BE SCREWED DOWN ONTO THE UPSTAND ANDPOSITIONED BY THE GRUB SCREW (REFER TO DETAL 2&SECTION 3B),SO THAT THE BACK OF THEHEAD FACES UPSTREAM.AFTER FIXING BOX TO UPSTAND,PAINT EXPOSED PIPE THREADS WITHGALVANISING TYPE PAINT.  \n3.2.THE TEST POINT FACE PLATES SHALL BE HANDLED SUCH THAT THEY ARE NOT SCRATCHED ORMARKED IN ANY WAY.  \n3.3.CABLE SHALL BE INSTALLED WITH SLACK IN PIPE TRENCH AND CONDUIT.BACKFILL MUST NOTDAMAGE CABLE OR CAUSE STRAIN ON CABLE TERMINATIONS.  \n3.4.ATTACHMENT OF CABLES AND COATING REINSTATEMENT SHALL BE IN ACCORDANCE WITH DRAWINGSAND IN ACCORDANCE WITH ANY RELEVANT FOREIGN STRUCTURE OWNERS REQUIREMENTS.FINAL TESTPOINT LOCATION&ARRANGEMENT SHALL BE SUBJECT TO THE DIRECTIVE OF THE COMPANY'SREPRESENTATIVE  \n# (4)REFERENCE ELECTRODE:\n\n4.1.REFERENCE ELECTRODE SHALL BE STABILISED ZINC TO AS 2239-1993 TYPE 1Z1 AND PER ANODEENGINEERING'S STANDARD DATA SHEET FOR STABILISED PERMANENT ZINC REFERENCE ELECTRODESTYPE AE-SPZRE-01.PERMANENT ELECTRODES SHALL BE SUPPLIED COMPLETE WITH A 10m TAIL OFFLEXIBLE COPPER CONDUCTOR (4mm PVC YELLOW).THE REFERENCE IS INA CALICO BAG FLLEDWITH GYPSUM BENTONITE(AS 2239-1993)PRIOR TO INSTALLATION,REMOVE THE PACKAGE FROM THEPROTECTIVE PLASTIC BAG.SOAK THE CELL AND BACKFLL IN FRESH WATER FOR 20 MINUTES.AFTERSOAKING,INSTALL THE CELL","cbCaigOqHgaXR6gl","https://ap.wps.com/l/cbCaigOqHgaXR6gl","pdf",200493,"English","# Installation & Connection Details\n## Front Elevation & Face Plate Details\n## Test Point Head Bill of Materials\n## Fabrication & General Notes\n## Reference Electrode\n## Foreign Crossing\n## Earthing Cable Attachments","[{\"question\":\"What components are specified in the type 2 test point head bill of materials?\",\"answer\":\"The document lists a face plate, neoprene gasket, test point upstand, flexible copper insulated cable, hex head bolt and washer, and crimp lugs, along with quantities for the assembly.\"},{\"question\":\"What general installation practices are required for the test point upstand and head threads?\",\"answer\":\"Threads on the test point upstand and head must be cleaned free of oil, grease, and dirt; the head is screwed down onto the upstand and positioned by the grub screw, then exposed pipe threads are painted with galvanising type paint.\"},{\"question\":\"How is the reference electrode stabilized and installed?\",\"answer\":\"The reference electrode is stabilized zinc type per the cited standard, supplied with a 10 m tail; it is installed in the pipe trench as shown after preparing by removing protective packaging, soaking, and backfilling as directed.\"}]","STANDARD DRAWING - TYPE 2 TEST POINT - Installation & Connection Details | PDF"]