[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663310-105":59,"doc-detail-663310-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","spusdot-as-built-drawing-requirements-as-built-drawing-submittals-and-cad-standards","SPU/SDOT As-Built Drawing Requirements - As-built drawing submittals and CAD standards","","SPU/SDOT As-Built Drawing Requirements define how to prepare accurate, clean, clear as-built drawings incorporating all deviations from the original design. The document specifies mandatory “AS-BUILT DRAWING” stamping, cross-out rules for items not built, and readability requirements including additional blow-up details in congested areas. It details submittal schedules and formats, plus four submission options covering AutoCAD/Civil 3D, DWF, PDF, and print markups, including required layer, color, annotation, barcode, and markup tool standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/spusdot-as-built-drawing-requirements-as-built-drawing-submittals-and-cad-standards/663310/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/spusdot-as-built-drawing-requirements-as-built-drawing-submittals-and-cad-standards/663310.png","ImageObject",300,407,{"name":92,"@type":93},"658056","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What must SPU/SDOT As-Built drawings include regarding deviations and references?","Question",{"text":112,"@type":113},"As-Built drawings must incorporate all deviations to the original design and must not include references to RFIs, FCRs, payment items, DCs, etc. The drawings must be accurate, clean, clear, and easily readable.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What stamp and correction rules apply to As-Built drawing sheets?",{"text":117,"@type":113},"All As-Built drawing sheets must be stamped “AS-BUILT DRAWING”. Items not built must be crossed out, and sheets must follow the readability guidance, including additional blow-up details when needed.",{"name":119,"@type":110,"acceptedAnswer":120},"What submission formats are allowed and what are the key markup requirements for each option?",{"text":121,"@type":113},"Submittals can be provided in AutoCAD DWG, DWF, PDF, or print. AutoCAD submissions must follow CAD Manual standards and specific layers/colors; DWF uses Autodesk Design Review with RED markups and 14 pt text; PDF uses Adobe Acrobat (not reader) with approved RED comment/markup tools and ~1/8” text; print uses RED ink markups and clearly written 1/8” lettering.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663310,1793226426,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":66,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":129,"read_time":24},658056,"SPU/SDOT As-Built Drawing Requirements  \n\n| Des ign Drawings\u003Cbr>Submit 30%, 60%, 90% & 100% drawings to City of Seattle for CAD reviews\u003Cbr>Submit all design change drawings to the City of Seattle As-designed data exported to City of Seattle GIS | | | Record Drawings\u003Cbr>\u003Cbr>Completed by the City of Seattle\u003Cbr>Data exported to City of Seattle GIS Plan set stored in the SPU Engineering Records Center |\n| --- | --- | --- | --- |\n\nGeneral Requirements  \n􀂉 As-Built drawings shall incorporate all deviations to the original design without any references to RFIs, FCRs, payment items, DCs, etc. As-Built drawings shall be accurate, clean, clear and easily readable. In congested areas, additional blow-up details may be required for readability.  \n􀂉 Items not built shall be crossed out.  \n􀂉 All As-Built drawing sheets shall be stamped “AS-BUILT DRAWING”.  \nSubmittals  \nSubmit [to](to SPU_CADsupport@Seattle.gov)[ SPU_CADsupport@Seattle.gov](to SPU_CADsupport@Seattle.gov) in one of four formats: AutoCAD DWG, DWF, PDF or print (paper) . AutoCAD DWG files are required if available.  \nSubmittal Option 1: AutoCAD Requirements  \n􀂉 Drawings shall be done in AutoCAD or AutoCAD Civil 3D and must conform to the standards as defined in the CAD Manual: [Seattle.gov/util/CAD](Seattle.gov/util/CAD)  \n􀂉 Civil layers for As-Built linework and annotation to be plotted/shown in red have the “CR-” discipline designator (see Section 5: Layers in the CAD Manual) and use colors 32-38 (see Section 8: Plotting/Printing in the CAD Manual) .  \n􀂉 Items not built shall be put on the CR-NBLT layer (lines can be broken) and crossed out with the CRANNO layer (not deleted) .  \n􀂉 Annotation shall have the text style name set to \"COS-Record\" with the “font name” set to RomanS.shx, the “paper text height” set to 0 .00, the “width factor” set to 1.00 and the “oblique angle” set to 20 (see Section 7: Annotation in the CAD Manual) . The plotted text height shall be 1/8”.  \n􀂉 All As-Built drawing sheets shall have the “AS-BUILT DRAWING” stamp block affixed (see Section 2: Support Files in the CAD Manual) .  \n􀂉 Sheet bar codes shall be correct (prior to printing, the “Barcode Modifier” field in the Sheet Set Custom Properties of Sheet Set Manager must be updated to: -A) .  \n􀂉 PDF, DWF or a hard-copy of the plan set created for reference per Section 8: Plotting/Printing in the CAD Manual with the standard plot style table.  \nSubmittal Option 2: DWF Requirements  \n􀂉 Markups must be done with Autodesk Design Review on full-size drawings (at least 22”x34”) .  \n􀂉 Markups must be done in RED color with the markup tools located in the “Markup & Measure” tab.  \n􀂉 Text must be 14 pt.  \nSubmittal Option 3: PDF Requirements  \n􀂉 Markups must be done with Adobe Acrobat (not reader) on full-size drawings (at least 22”x34”) .  \n􀂉 Markups must be done in RED color with the following “Comment & Markup” tools: Callout Tool, Text Box Tool, Cloud Tool, Arrow Tool, Line Tool, Rectangle Tool, Oval Tool, Polygon Line Tool and/or Polygon Tool (sticky notes are not valid) .  \n􀂉 Text must be approximately 1/8”.  \nSubmittal Option 4: Print Requirements  \n􀂉 Markups must be done in RED ink on full-size (at least 22x34) drawing prints.  \n􀂉 Handwriting must be clearly written with 1/8” lettering.","cbCaikPf1X1opchE","https://ap.wps.com/l/cbCaikPf1X1opchE","pdf",414784,"English","# General Requirements\n## Submittals\n### Submittal Option 1: AutoCAD Requirements\n### Submittal Option 2: DWF Requirements\n### Submittal Option 3: PDF Requirements\n### Submittal Option 4: Print Requirements","[{\"question\":\"What must SPU/SDOT As-Built drawings include regarding deviations and references?\",\"answer\":\"As-Built drawings must incorporate all deviations to the original design and must not include references to RFIs, FCRs, payment items, DCs, etc. The drawings must be accurate, clean, clear, and easily readable.\"},{\"question\":\"What stamp and correction rules apply to As-Built drawing sheets?\",\"answer\":\"All As-Built drawing sheets must be stamped “AS-BUILT DRAWING”. Items not built must be crossed out, and sheets must follow the readability guidance, including additional blow-up details when needed.\"},{\"question\":\"What submission formats are allowed and what are the key markup requirements for each option?\",\"answer\":\"Submittals can be provided in AutoCAD DWG, DWF, PDF, or print. AutoCAD submissions must follow CAD Manual standards and specific layers/colors; DWF uses Autodesk Design Review with RED markups and 14 pt text; PDF uses Adobe Acrobat (not reader) with approved RED comment/markup tools and ~1/8” text; print uses RED ink markups and clearly written 1/8” lettering.\"}]","SPU/SDOT As-Built Drawing Requirements - As-built drawing submittals and CAD standards | PDF"]