[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650090-105":59,"doc-detail-650090-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","sprinkler-design-data-part-fire-protection-plans","Sprinkler Design Data - Part - Fire Protection Plans","","Sprinkler Design Data and fire protection construction plan sheets for the City of Raleigh Fire Department. Includes sprinkler design summary fields such as system information, design method, design area, spacing, density, k-factor, hose allowance, gpm/psi requirements, and safety factors, plus dry system volume. Provides water supply information, fire pump data, and worksheet tables for storage commodity design when storage height exceeds 12 feet. Also covers reflective ceiling plan, piping plan, riser details for wet and dry systems, riser clearance, standpipe pressure summary, fire pump isometric/elevations, and sprinkler legend with model/type, rating, and coverage notations.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/sprinkler-design-data-part-fire-protection-plans/650090/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/sprinkler-design-data-part-fire-protection-plans/650090.png","ImageObject",300,407,{"name":92,"@type":93},"Aurelia","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does the Sprinkler Design Data section include?","Question",{"text":112,"@type":113},"It includes a design summary with system identifiers, design method and area, sprinkler spacing, density, k-factor, hose allowance, required gpm/psi, and safety factors, along with dry system volume.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What water supply information is required?",{"text":117,"@type":113},"The sheets list hydrant elevation and hydrant flow testing values including static and residual pressure, flow gpm, and a requirement that a copy of water test data used with the calculation is included.",{"name":119,"@type":110,"acceptedAnswer":120},"What drawings and details are provided beyond design tables?",{"text":121,"@type":113},"The document includes sprinkler reflective ceiling and piping plans, riser details for wet and dry systems, riser clearance and standpipe pressure summary, fire pump isometric and elevations, and a sprinkler legend describing sprinkler types/models and ratings.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650090,1792816594,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},1099514068365,"https://ap-avatar.wpscdn.com/avatar/10000253d8d9f28188e?_k=1776742907772140068","DRAWNG NO.  \nSprinkler Design Data  \n\n| Project Name:   |  | System:   |\n| --- | --- | --- |\n| Project Street Address:   |  | Sys.Sq.Ft.:   |\n| Suite:   | Floor\\#:   | Ceiling Height:   |\n| Designed By.   | Phone:   | Total Bldg.Hgt.:   |\n| Occupancy.   | Hazard:   |  |\n\nFP-1  \nDATE:  \nDesign Summary  \n\n|  | System \\#   | System \\#   | System \\#   | System\\#   | System \\#   |\n| --- | --- | --- | --- | --- | --- |\n| Design Method   |  |  |  |  |  |\n| Design Area\\#   |  |  |  |  |  |\n| Location   |  |  |  |  |  |\n| Type of System   |  |  |  |  |  |\n| Hazard Class   |  |  |  |  |  |\n| Criteria From   |  |  |  |  |  |\n| Design Area   |  |  |  |  |  |\n| Sprinkler Spacing   |  |  |  |  |  |\n| Density   |  |  |  |  |  |\n| K-factor   |  |  |  |  |  |\n| Hose Allowance   |  |  |  |  |  |\n| \\#Design Sprinklers   |  |  |  |  |  |\n| Special Application Spk.   |  |  |  |  |  |\n| Requirement   |  |  |  |  |  |\n| G.P.M.Req'd   |  |  |  |  |  |\n| P.S.I.Req'd   |  |  |  |  |  |\n| Safety Factor o   |  |  |  |  |  |\n| Safety Factor(PSI)   |  |  |  |  |  |\n|  |  |  |  |  |  |\n| Dry Sys.Volume(gal)   |  |  |  |  |  |\n\n90115  \nREVSIONS:  \nSPRINKLER D3SIGN DATA  \nWater Supply Information  \n\n| Tested by   |  | Date/Time   |  | Pressure Hydrant   |  |\n| --- | --- | --- | --- | --- | --- |\n| Hydrant Elevation   |  | Flow Hydrant\\#1   |  | Flow Hydrant \\#2   |  |\n| Static(PSI)   |  | Residiual(PSI)   |  | Flow(gpm)   |  |\n| Copy of Water Test Data Included with Calculation is required   |  |  |  |  |  |\n\nDESRIPTLON:  \nFire Pump Data  \n\n| Rated G.P.M.   |  | Rated Pressure   |  | Horsepower   |  |\n| --- | --- | --- | --- | --- | --- |\n| Diesel/Electric   |  | Churn Pressure   |  | Style of pump   |  |\n| Combined Discharge   |  | 150%Flow(suction)   |  | 150%Flow(gpm)   |  |\n| Certified pump curve required   |  |  |  |  |  |\n\nCITY OF RALEIGH FIRE DEPRTMENT  \n310 WEST MARTIN ST.RALEIGH,NC 27602  \nIf Storage is Greater than 12 Feet Complete Commodity Storage Design Information  \n\n| Comodity Description   |  |  |  |  |  |  | Storage Type(Rack,Bin,Pile)   |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Comodity Class   |  |  |  | Storage Height   |  |  |  |  |  | Clearance   |  |  |  |  |  |\n| Stable/Unstable   |  |  |  | Open/Close  \u003Cbr>Array   |  |  |  |  |  | Wet/Dry  \u003Cbr>System   |  |  |  |  |  |\n| Figure  \u003Cbr>\\#   | Curve  \u003Cbr>\\#   |  | Density   |  | Height  \u003Cbr>Factor   | Clear  \u003Cbr>Factor   |  | Array  \u003Cbr>Factor   | Dry  \u003Cbr>Penalty   |  | Design   |  | Minimum  \u003Cbr>Design   |  | Final  \u003Cbr>Design   |\n|  |  |  | Area   |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  | Initial   |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  | Secon  \u003Cbr>-dary   |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Is system compliant with Chapter 23(FPC)   |  |  |  |  |  | Is storage area layout,rack,and pile plan included?   |  |  |  |  |  |  |  |  |  |\n\nFIRE PROTECTION DIVSION  \n# SPRINKLER REFLECTIVE CEILING PLAN\n\nSCALE:  NTSCITY OF RALEIGH FIRE DEPARTMENT  \nDESCRIPTION:REVISIONS:DATE:FIRE PROTECTION DIVISION310 WEST MARTIN ST.RALEIGH,NC 27602SPRINKLER REFLECTIVE CEILING5-1-06  w Warren            \nDRAWING NO.  \nFP-2  \n# SPRINKLER PIPING PLAN\n\n\n|  |  |  |  |\n| --- | --- | --- | --- |\n| DESCRIPTION:  \u003Cbr>SPRINKLER PIPING PLAN   | REVISIONS:  \u003Cbr>5wa1e06   | DATE:   | DRAWING NO.  \u003Cbr>FP-3   |\n\nCITY OF RALEIGH FIRE DEPARTMENT  \nFIRE PROTECTION DIVISION  \n310 WEST MARTIN ST.RALEIGH,NC 27602  \nNOT TO SCALE  \nDESCRIPTION:  \nSPRINKLER RISER DETAIL(WET)  \nDATE:  \n1-25-2010  \nDRAWNG NO.  \nFP-4B  \nDETAIL W-7  \n# SPRINKLER RISER\n\nNOT TO SCALE  \n\n| CITY OF RALEIGH FIRE DEPARTMENT  \u003Cbr>FIRE PROTECTION DIVISION  \u003Cbr>310 WEST MARTIN ST.RALEIGH,NC 27602   |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n|  | DESCRIPTION:  \u003Cbr>SPRINKLER RISER DETAIL(DRY)   | REVSIONS:  \u003Cbr>5-1-06   | DATE:   |  | DRAWNG NO","cbCaibMnIqpNVdxZ","https://ap.wps.com/l/cbCaibMnIqpNVdxZ","pdf",2443045,29,"English","# Sprinkler Design Data\n## Design Summary\n## Water Supply Information\n## Fire Pump Data\n# Fire Protection Division Drawings\n## Sprinkler Reflective Ceiling Plan\n## Sprinkler Piping Plan\n## Sprinkler Riser Detail (Wet)\n## Sprinkler Riser Detail (Dry)\n## Riser Clearance Detail\n## Fire Pump Isometric\n## Fire Pump Elevations\n## Sprinkler Legend","[{\"question\":\"What does the Sprinkler Design Data section include?\",\"answer\":\"It includes a design summary with system identifiers, design method and area, sprinkler spacing, density, k-factor, hose allowance, required gpm/psi, and safety factors, along with dry system volume.\"},{\"question\":\"What water supply information is required?\",\"answer\":\"The sheets list hydrant elevation and hydrant flow testing values including static and residual pressure, flow gpm, and a requirement that a copy of water test data used with the calculation is included.\"},{\"question\":\"What drawings and details are provided beyond design tables?\",\"answer\":\"The document includes sprinkler reflective ceiling and piping plans, riser details for wet and dry systems, riser clearance and standpipe pressure summary, fire pump isometric and elevations, and a sprinkler legend describing sprinkler types/models and ratings.\"}]","Sprinkler Design Data - Part - Fire Protection Plans | PDF",73]