[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-217225-en":3,"doc-seo-217225-105":30,"detail-sidebar-cat-0-en-105":91},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":4,"category_id":11,"category_name":12,"doc_title":13,"doc_description":14,"doc_content":15,"file_id":16,"file_url":17,"file_type":18,"file_size":19,"view_count":20,"is_deleted":4,"is_public":20,"is_downloadable":20,"audit_status":20,"page_count":21,"language":22,"language_code":23,"site_id":24,"html_lang":23,"table_of_contents":25,"faqs":26,"seo_title":27,"seo_description":14,"update_tm":28,"read_time":29},217225,962075114765,"Quinn","https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd",6,"Technology","SPH 10000TL-HU-US  Datasheet - Solar Inverter Specifications","SPH 10000TL-HU-US is a 10kW-class hybrid solar inverter supporting UPS function with a 10ms transition time and multiple MPPTs for flexible PV input. It accepts DC-coupled, AC-coupled, and AC-retrofit configurations, supports up to 200A charging/discharging current, and enables diesel generator charging. Parallel operation up to 6 units is supported for 220V or 208V three-phase systems, with DC/AC Type II surge protection, advanced monitoring, and lithium or lead-acid battery compatibility. Key metrics include peak efficiency up to 97.50%, CEC weighted efficiency 97%, and MPPT efficiency ≥99.5%.","SPH 10000TL-HU-US  \n· UPS function, 10ms transition  \n·1.5 DC/AC Ratio with 3 Mppts  \n· Up to 200A charging/discharging current  \n· Support DC-coupled, AC-coupled, AC-retrofit applications  \n· Type II Surge protection for DC and AC sides  \n· Support charge from diesel generator  \n· Support up to 6 units in parallel  \n· Support form a 220V or 208V three-phase system  \n[https://us.growatt.com](https://us.growatt.com)  \nDatasheet SPH 10000TL-HU-US  \n\n| Input data (DC) |  |  |\n| --- | --- | --- |\n| Max. recommended PV power (for module STC) | 15000W |  |\n| Max. input power for single MPPT | 10000W |  |\n| Max. DC voltage | 525V |  |\n| Startup voltage | 150V |  |\n| MPP voltage range | 150V-450V/370V |  |\n| No. of MPP trackers | 3 |  |\n| No. of PV strings per MPP tracker | 2 |  |\n| Max. input current per MPP tracker | 22A |  |\n| Max. short-circuit current per MPP tracker | 27A |  |\n| AC input data (AC) |  |  |\n| Nominal AC input power | 10000W |  |\n| Nominal input voltage | 240V |  |\n| Nominal input current | 41.67A |  |\n| Output data (AC) |  |  |\n| AC nominal power | 10000W |  |\n| Max. AC apparent power | 10000VA |  |\n| Nominal AC voltage (range*) | 120V/208V, 120V/240V Split (180Vac-280Vac) |  |\n| AC grid frequency (range*) | 50Hz/60Hz |  |\n| Max. output current | 50A |  |\n| Adjustable power factor | 1.0leading…1.0lagging |  |\n| THDi | \u003C3% |  |\n| AC grid connection type | L1/L2/N/PE |  |\n| Battery data (DC) |  |  |\n| Battery voltage range\u003Cbr>Max charging and discharging current |  | 40~60V\u003Cbr>200A |\n| Continuous charging and discharging power |  | 10000W |\n| Communication protocol |  | CAN/RS485 |\n| Type of battery |  | Lithium /Lead-acid |\n| Backup power (AC) |  |  |\n| AC nominal output power | 10000W |  |\n| Nominal AC output voltage | 120/208V, 120V/240V Split |  |\n| Nominal AC output frequency | 50/60Hz |  |\n| Switch time | \u003C10ms |  |\n| Overload capability\u003Cbr>Efficiency | 13000W for 5 s |  |\n| Peak efficiency | 97.50% |  |\n| CEC weighted efficiency | 97% |  |\n| MPPT efficiency | ≥99.5% |  |\n| Protection devices |  |  |\n| PV switch | Yes |  |\n| AC over current protection | Yes |  |\n| AC over voltage protection | Yes |  |\n| Ground fault monitoring | Yes |  |\n| Grid monitoring | Yes |  |\n| Anti-islanding protection | Yes |  |\n| Residual-current monitoring unit | Yes |  |\n| Insulation resistance monitoring | Yes |  |\n| AFCI Protection | Yes |  |\n| Surge protection | DC Type II/AC Type II |  |\n| General data |  |  |\n| Dimensions (W / H / D) | 440/855/256mm (17.32/28.34/9.44) inches |  |\n| Weight | 48.84kg/107.8Ibs |  |\n| Operating temperature range | –25°C ... +60°C (-13...+140°F) with derating above 45°C /113°F |  |\n| Noise emission (typical) | ≤ 30 dB(A) |  |\n| Max. grid passthrough current | 62.5A |  |\n| Max. generator input power | 10000W |  |\n| Max stackable number | 6 |  |\n| RSD transmitter | Tigo/APsmart |  |\n| Self-consumption | \u003C 60 W |  |\n| Topology | Tranformerless |  |\n| Cooling | Smart cooling |  |\n| Protection degree | IP65/NEMA 4 |  |\n| Relative humidity | 0~ 100% |  |\n| Altitude | 2000m |  |\n| DC connection | Quick connector |  |\n| Display | LCD |  |\n| Interfaces: RS485/CAN/USB | Yes |  |\n| Communication | WIFI/4G cellular (Opt) |  |\n| Warranty | 10 years |  |\n\nIEEE1547, CA RULE21, RULE14(HECO Compliant), UL1741, UL1741SA/SB, CSA C22.2, PREPA, UL1699B, UL1741 CRD, IEC62109-1, IEC62109-2,FCC Part15 Class B, Sunspec  \n* SHENZHEN GROWATT NEW ENERGY CO.,LTD All rights reserved. Subject to change without notice.  \nGROWATT USA INC.Address: 9227 Reseda Blvd. \\#435 Northridge, CA 91324. Sales Hotline : 818 800 9455 Service Hotline : 1866 686 0298  \nEmail: [usa@ginverter.com](usa@ginverter.com)","cbCailRjJ70rx6Eh","https://ap.wps.com/l/cbCailRjJ70rx6Eh","pdf",2313535,1,2,"English","en",105,"# Key Features\n## UPS function and transition time\n## MPPT and PV input capability\n## Battery and communication support\n# Electrical Specifications\n## Input (DC)\n## Input (AC)\n## Output (AC)\n# Performance and Protection\n## Efficiency\n## Overload capability\n## Protection devices\n# General Specifications\n## Dimensions and weight\n## Operating conditions\n## Interfaces and warranty","[{\"question\":\"What UPS function and transfer time does SPH 10000TL-HU-US support?\",\"answer\":\"It supports UPS function with a 10ms transition time.\"},{\"question\":\"How many MPPT trackers does the inverter include and what is the MPPT voltage range?\",\"answer\":\"It has 3 MPPT trackers, with an MPP voltage range of 150V–450V / 370V.\"},{\"question\":\"What battery types and communication protocols are supported?\",\"answer\":\"It supports lithium and lead-acid batteries, and communication protocols include CAN and RS485.\"}]","SPH 10000TL-HU-US  Datasheet - Solar Inverter Specifications | PDF",1788831574,5,{"code":4,"msg":31,"data":32},"ok",{"site_id":24,"language":23,"slug":33,"title":13,"keywords":34,"description":14,"schema_data":35,"social_meta":86,"head_meta":88,"extra_data":90,"updated_unix":28},"sph-10000tl-hu-us-datasheet-solar-inverter-specifications","",{"@graph":36,"@context":85},[37,53,68],{"@type":38,"itemListElement":39},"BreadcrumbList",[40,44,47,50],{"item":41,"name":42,"@type":43,"position":20},"https://docshare.wps.com","Home","ListItem",{"item":45,"name":46,"@type":43,"position":21},"https://docshare.wps.com/document/","Document",{"item":48,"name":12,"@type":43,"position":49},"https://docshare.wps.com/document/technology/",3,{"item":51,"name":13,"@type":43,"position":52},"https://docshare.wps.com/document/sph-10000tl-hu-us-datasheet-solar-inverter-specifications/217225/",4,{"url":51,"name":13,"@type":54,"author":55,"headline":13,"publisher":57,"fileFormat":60,"inLanguage":23,"description":14,"dateModified":61,"datePublished":62,"encodingFormat":60,"isAccessibleForFree":63,"interactionStatistic":64},"DigitalDocument",{"name":9,"@type":56},"Person",{"url":41,"name":58,"@type":59},"DocShare","Organization","application/pdf","2026-09-11","2026-09-08",true,{"@type":65,"interactionType":66,"userInteractionCount":20},"InteractionCounter",{"@type":67},"ViewAction",{"@type":69,"mainEntity":70},"FAQPage",[71,77,81],{"name":72,"@type":73,"acceptedAnswer":74},"What UPS function and transfer time does SPH 10000TL-HU-US support?","Question",{"text":75,"@type":76},"It supports UPS function with a 10ms transition time.","Answer",{"name":78,"@type":73,"acceptedAnswer":79},"How many MPPT trackers does the inverter include and what is the MPPT voltage range?",{"text":80,"@type":76},"It has 3 MPPT trackers, with an MPP voltage range of 150V–450V / 370V.",{"name":82,"@type":73,"acceptedAnswer":83},"What battery types and communication protocols are supported?",{"text":84,"@type":76},"It supports lithium and lead-acid batteries, and communication protocols include CAN and RS485.","https://schema.org",{"og:url":51,"og:type":87,"og:title":13,"og:site_name":58,"og:description":14},"article",{"robots":89,"canonical":51},"index,follow",{"doc_id":7,"site_id":24},{"code":4,"msg":5,"data":92},[93,97,101,105,109,112,117,122,127,130,134],{"id":20,"doc_module":4,"doc_module_name":46,"category_name":94,"show_sort_weight":95,"slug":96},"Story & Novel",90,"story-novel",{"id":21,"doc_module":4,"doc_module_name":46,"category_name":98,"show_sort_weight":99,"slug":100},"Literature",80,"literature",{"id":52,"doc_module":4,"doc_module_name":46,"category_name":102,"show_sort_weight":103,"slug":104},"Exam",70,"exam",{"id":29,"doc_module":4,"doc_module_name":46,"category_name":106,"show_sort_weight":107,"slug":108},"Comic",60,"comic",{"id":11,"doc_module":4,"doc_module_name":46,"category_name":12,"show_sort_weight":110,"slug":111},50,"technology",{"id":113,"doc_module":4,"doc_module_name":46,"category_name":114,"show_sort_weight":115,"slug":116},7,"Healthcare",40,"healthcare",{"id":118,"doc_module":4,"doc_module_name":46,"category_name":119,"show_sort_weight":120,"slug":121},8,"Research & Report",30,"research-report",{"id":123,"doc_module":4,"doc_module_name":46,"category_name":124,"show_sort_weight":125,"slug":126},9,"Religion & Spirituality",20,"religion-spirituality",{"id":125,"doc_module":4,"doc_module_name":46,"category_name":128,"show_sort_weight":125,"slug":129},"World Cup","world-cup",{"id":131,"doc_module":4,"doc_module_name":46,"category_name":132,"show_sort_weight":131,"slug":133},10,"Lifestyle","lifestyle",{"id":135,"doc_module":4,"doc_module_name":46,"category_name":136,"show_sort_weight":29,"slug":137},19,"General","general"]