[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-677064-105":59,"doc-detail-677064-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","speedaire-by-dayton-refrigerated-compressed-air-dryers-operating-instructions-and-parts-manual","Speedaire by Dayton Refrigerated Compressed Air Dryers Operating Instructions and Parts Manual","","Operating instructions and parts manual for Speedaire by Dayton refrigerated compressed air dryers models 3YA51, 3YA52, 3YA53, and 3YA54. Describes purpose and benefits of cooling compressed air to condense and remove water vapor to keep air tools and downstream devices clean and dry. Provides receiving and unpacking inspection guidance, safe handling during moving, storage limits, general safety rules for pressure and electricity, installation location and clearances, piping and moisture separator considerations, and operating specifications including electrical requirements and flow capacity.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/speedaire-by-dayton-refrigerated-compressed-air-dryers-operating-instructions-and-parts-manual/677064/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/speedaire-by-dayton-refrigerated-compressed-air-dryers-operating-instructions-and-parts-manual/677064.png","ImageObject",300,407,{"name":92,"@type":93},"adawds","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is the main purpose of these refrigerated compressed air dryers?","Question",{"text":111,"@type":112},"They cool compressed air to condense water vapor into liquid form so it can be removed from the air system, helping keep air tools and other air-operated devices clean and dry.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What safety steps are required before servicing or disassembling the dryer?",{"text":116,"@type":112},"Do not exceed the maximum operating pressure shown on the equipment serial number tag, and make sure the equipment is depressurized before working on or disassembling it for service.",{"name":118,"@type":109,"acceptedAnswer":119},"What installation and clearance guidance is provided?",{"text":120,"@type":112},"Locate the dryer to avoid drawing harmful contaminants into the system, allow at least 6 inches clearance from the front and condenser sides (24 inches on the 75 scfm model), and allow 24 inches clearance for maintenance.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},677064,1793777461,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":46},3985747872983,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Operating Instructions and Parts Manual 3YA51, 3YA52, 3YA53 and 3YA54  \nPlease read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.  \nSpeedaire® by Dayton® Refrigerated  \nCompressed Air Dryers  \nDescription  \nSpeedaire by Dayton refrigerated compressed air dryers are used to cool compressed air to 38° to 50°F (3° to 10°C), thereby condensing water vapor in the compressed air to liquid form, for removal from your air system. Removal of this water vapor allows you to keep air tools, air valves and cylinders, spray guns, and any air operated device clean and dry. This reduces downtime and maintenance from malfunctioning equipment due to dirt and water. Speedaire by Dayton dryers work best when sized close to the cubic feet per minute load as rated. Following the installation and maintenance information will result in maximum performance and life from the dryers.  \nReceiving  \nThis shipment has been thoroughly checked, packed and inspected before leaving our plant. It was received in good condition by the carrier and was so acknowledged.  \nCheck for visible loss or damage. If this shipment shows evidence of loss or damage at time of delivery to you, insist that a notation of this loss or damage be made on the delivery receipt by the carrier’s agent.  \nUnpacking  \nCheck for concealed loss or damage. When a shipment has been delivered to you in apparent  \ngood order, but concealed damage is  \nSpecifications  \nfound upon unpacking, notify the carrier immediately and insist on his agent inspecting the shipment. Concealed damage claims are not our responsibility as our terms are F.O. B. point of shipment.  \nMoving  \nIn moving or transporting dryer, do not tip dryer onto its side.  \nStorage  \nIMPORTANT-Do not store dryer in temperatures above 130°F, 54.4°C.  \nGeneral Safety Information  \n1. This equipment is a pressure containing device. Do not exceed  \nmaximum operating pressure as shown on equipment serial number tag. Make sure equipment is depressurized before working on or disassembling it for service.  \n2. This equipment requires electricity to operate. Install equipment in  \ncompliance with all applicable electrical codes. Standard equipment is supplied with electrical enclosures not intended for installation in hazardous environments. Disconnect power supply to equipment when performing any electrical service work.  \n3. Air treated by this equipment may not be suitable for breathing without further purification. Refer to applicable standards and specifications for the requirements for breathing quality air.  \nAIR CONNECTION MAXIMUM DIMENSIONS  \nWorking Inlet Height Width Depth Weight  \nModel Inlet/Outlet Pressure Temperature (lbs)  \nForm 5S5374  \n5/05  \nPrinted in U.S.A. 04757 0505/188/VCPVP  \n8610.481.2A  \nINTERNAL USE ONLY  \n8610.483.7/031043  \n3YA51, 3YA52, 3YA53 and 3YA54  \nSpeedaire by Dayton Operating Instructions and Parts Manual  \nSpeedaire® by Dayton® Refrigerated  \nCompressed Air Dryers  \nE  \nN  \nG  \nL I  \nS  \nH  \nInstallation  \nLOCATION  \n1. For typical placement in a compressed air system, see Figure 1.  \n2. Air compressor intake-Locate air compressor so that contaminants potentially harmful to the dryer (e.g. ammonia) are not drawn into the air system.  \n3. Clearances  \nFree air flow-Allow at least 6 inches (153 mm) clearance (24 inches on 75 scfm model) from the front and from the condenser sides of the cabinet.  \nService-To facilitate maintenance, allow 24”(610 mm) of clearance for maintenance.  \n4. Standard units are designed to operate in ambients from 40 to 113°F (4 to 45°C) .  \nMOUNTING  \nDryer may be installed on a suitable shelf or floor stand.  \nPIPING  \n1. Air Inlet-Connect compressed airline from air source to air inlet.  \nRefer to s","cbCaibUCUulVvdrq","https://ap.wps.com/l/cbCaibUCUulVvdrq","pdf",4705078,"English","# Receiving\n# Unpacking\n# Moving\n# Storage\n# General Safety Information\n# Installation\n## Location and Clearances\n## Mounting\n## Piping and Connections\n## Moisture Separator\n# Electrical and Flow Capacity","[{\"question\":\"What is the main purpose of these refrigerated compressed air dryers?\",\"answer\":\"They cool compressed air to condense water vapor into liquid form so it can be removed from the air system, helping keep air tools and other air-operated devices clean and dry.\"},{\"question\":\"What safety steps are required before servicing or disassembling the dryer?\",\"answer\":\"Do not exceed the maximum operating pressure shown on the equipment serial number tag, and make sure the equipment is depressurized before working on or disassembling it for service.\"},{\"question\":\"What installation and clearance guidance is provided?\",\"answer\":\"Locate the dryer to avoid drawing harmful contaminants into the system, allow at least 6 inches clearance from the front and condenser sides (24 inches on the 75 scfm model), and allow 24 inches clearance for maintenance.\"}]","Speedaire by Dayton Refrigerated Compressed Air Dryers Operating Instructions and Parts Manual | PDF"]