[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505663-105":59,"doc-detail-505663-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","source-testing-and-test-reporting-guidelines","SOURCE TESTING AND TEST REPORTING GUIDELINES","","Guidelines for conducting and reporting source tests under Nevada’s Air Quality Operating Permit and applicable federal and state regulations. They define testing requirements, approval for deviations to reference test methods, minimum sampling volumes and durations for particulate and gaseous species, and representative material analysis expectations. Reporting rules require timely notification within 24 hours for excess emissions, clear identification of deviations in the first three pages, inclusion of raw data, and adherence to isokinetic sampling and operating conditions, with potential test rejection criteria.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/source-testing-and-test-reporting-guidelines/505663/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/source-testing-and-test-reporting-guidelines/505663.png","ImageObject",300,407,{"name":92,"@type":93},"gewufjwa","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How must source tests be conducted under Nevada requirements?","Question",{"text":112,"@type":113},"Source tests must follow the facility’s Air Quality Operating Permit and applicable state and federal regulations. Any deviations to federal reference test methods require prior approval from the Director.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the minimum sampling volumes, durations, and durations for different test types?",{"text":117,"@type":113},"Particulate matter test runs must run at least one hour and either collect at least 1.7 dry dscm (60 dscf) or be conducted up to two hours to maximize sample volume. Gaseous species test runs require a minimum duration of one hour.",{"name":119,"@type":110,"acceptedAnswer":120},"When and how are excess emissions during source testing required to be reported?",{"text":121,"@type":113},"Any emission or opacity limit exceeded during a source test must be reported within 24 hours to NDEP-BAPC as required by NAC 445B.232. Permit exceedances will be evaluated under the air quality regulations and may result in a Notice of Alleged Air Quality Violation and Order.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},505663,1791761825,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},3985747882900,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Nevada Division of Environmental Protection  \nBureau of Air Pollution Control / Bureau of Air Quality Planning SOURCE TESTING AND TEST REPORTING GUIDELINES  \nTESTING REQUIREMENTS  \nSource tests shall be conducted in accordance with the requirements established in the facility’s Air Quality Operating Permit and with applicable state and federal regulations.  \n• Any deviations to the federal reference test methods shall be approved by the Director prior to conducting the tests. The absence of cyclonic flow must be verified before testing any system.  \n• Source tests shall be conducted at the maximum fuel consumption rate, production rate, or other operating parameters established in the Permit. The hourly documentation for these parameters during the source test shall be included in the source test report. If any test is conducted at less than permitted maximum capacity, or at a lower fuel rate, production rate or heat input rate, the test results will be evaluated against the permit operating conditions and the permit may need to be revised accordingly.  \n• For all particulate matter test runs, the NDEP-BAPC has established minimum sampling volumes and sampling times (test run durations). Test runs shall be conducted for a minimum of one hour, and shall either collect a minimum sample volume of 1.7 dry standard cubic meters (dscm, or 60 dscf) or be conducted for up to 2 hours to maximize the sample volume.  \n• For all gaseous species test runs, the NDEP-BAPC requires minimum test duration of 1 hour.  \n• The NDEP-BAPC requires the analysis of a representative sample of the ore, fuel or other material processed or combusted during the source testing of each system if the emissions may be affected by the composition of the material in the process. The NDEP-BAPC requires that a minimum of one sample shall be taken during each day that a particular emissions unit is tested, but may require that a sample be taken during each test run. The analysis report shall state the date the sample was analyzed and refer to the emission unit through which the ore/material was processed. The analysis report shall include content (sulfur, metals, moisture, etc…) of the ore, fuel, or other material and shall be submitted in the source test report.  \n• Any emission limit or operating parameter exceeded at the time of the source test must be reported within 24 hours to NDEP-BAPC as required in the Nevada Administrative Code (NAC) 445B.232 “Excess emissions; Scheduled maintenance, testing or repairs; notification of director; malfunction, upset, startup, shutdown or human error.” Reported permit exceedances will be evaluated in accordance with the Air Quality regulations and may result in a Notice of Alleged Air Quality Violation and Order (NOAV) . Failure to properly report an exceedance of a permitted emissions limit represents the basis for a NOAV.  \n• Any calibration gases used for source tests shall be certified prior to the tests and have valid certification dates during the tests. Only a certified independent laboratory shall certify the calibration gases.  \nThe NDEP-BAPC may reject emissions tests for any of the following reasons:  \n1) Failure to comply with all provisions of NAC 445B.252 “Testing and sampling.”  \n2) Any deviation from U.S. EPA Reference Test Methods unless specifically approved by the NDEP-BAPC.  \n3) For any source subject to the New Source Performance Standards (NSPS) 40 CFR Part 60, failure to meet any additional testing requirements stated in the applicable Subpart.  \n4) Failure to achieve isokinetic sampling rates (+/ -10% Method 5 for PM, +/ -20% Method 201A for PM10) for any of the three required test runs.  \n5) Failure to provide relevant process and production information for the period of each test run.  \n6) Failure to achieve the operating conditions (e.g., throughput rate, heat input rate, fuel flow rate, emission limits) specified in Section IV or V of the Air Quality Operating Permit during each test run.  \nSOURCE","cbCaitZIM9JtoR6D","https://ap.wps.com/l/cbCaitZIM9JtoR6D","pdf",68617,"English","# TESTING REQUIREMENTS\n## Source Test Conduct and Approval of Deviations\n## Minimum Sampling Volumes and Durations\n## Material Analysis Requirements\n## Excess Emissions Notification\n## Calibration Gas Certification\n# SOURCE TEST REPORTING GUIDELINES\n## Complete Test Report Submission\n## 24-Hour Excess Emissions Reporting\n## Deviation Identification in First Three Pages\n## Operating Deviation Explanations\n## System and Unit Identification\n## Unit Consistency for Operating Parameters\n## Inclusion of Raw Data Sheets and Run Validity","[{\"question\":\"How must source tests be conducted under Nevada requirements?\",\"answer\":\"Source tests must follow the facility’s Air Quality Operating Permit and applicable state and federal regulations. Any deviations to federal reference test methods require prior approval from the Director.\"},{\"question\":\"What are the minimum sampling volumes, durations, and durations for different test types?\",\"answer\":\"Particulate matter test runs must run at least one hour and either collect at least 1.7 dry dscm (60 dscf) or be conducted up to two hours to maximize sample volume. Gaseous species test runs require a minimum duration of one hour.\"},{\"question\":\"When and how are excess emissions during source testing required to be reported?\",\"answer\":\"Any emission or opacity limit exceeded during a source test must be reported within 24 hours to NDEP-BAPC as required by NAC 445B.232. Permit exceedances will be evaluated under the air quality regulations and may result in a Notice of Alleged Air Quality Violation and Order.\"}]","SOURCE TESTING AND TEST REPORTING GUIDELINES | PDF",1791152903,13,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0bc9415c8d0eb4c3f145a876ac50ea3c.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/06dedf97ce80959b480aacfc4aa33451.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/cc0be787860e84abe3cfc128bd1681c5.webp",981,1269,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/63ffdf8a8854b849411c65347607b9b4.webp",980,1268]