[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-561689-105":59,"doc-detail-561689-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","solid-state-relays-g3na-ordering-information-model-number-structure-and-specifications","Solid State Relays - G3NA - Ordering Information, Model Number Structure, and Specifications","","Solid State Relays G3NA provide compact, uniform mounting dimensions and include a built-in varistor to absorb external surges (with one model exception). The operation indicator supports monitoring, and a protective cover improves safety. The document explains certification coverage (UL, CSA, TÜV), the scheduled closing of certain orders, and how to interpret the G3NA model number structure. It also lists ordering models with isolation and zero-cross function options, provides load/applicable voltage notes, and details compatible accessories such as mounting plates and heat sinks.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/solid-state-relays-g3na-ordering-information-model-number-structure-and-specifications/561689/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/solid-state-relays-g3na-ordering-information-model-number-structure-and-specifications/561689.png","ImageObject",300,407,{"name":92,"@type":93},"Ben ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-19","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the main features of the G3NA solid state relays?","Question",{"text":112,"@type":113},"G3NA relays share compact uniform dimensions, include a built-in varistor for surge absorption (except the specified model), and offer an operation indicator for monitoring. A protective cover is also provided for safety.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the document describe the G3NA model number structure?",{"text":117,"@type":113},"The model number is decomposed into fields such as basic model name (G3NA), load power supply (AC/DC), rated load voltage and rated load current, terminal type, zero-cross function, and certification suffix (e.g., UTU).",{"name":119,"@type":110,"acceptedAnswer":120},"What information is given in the ordering information section?",{"text":121,"@type":113},"The ordering section lists available models with isolation type, whether zero-cross function and indicator are included, applicable output load and rated input voltage ranges, plus notes about load conditions and loss time. It also indicates that order closure is scheduled for the end of March 2020 for specified model groups.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},561689,1791865184,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":56,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},2336478951081,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Solid State Relays  \nG3NA  \nThe reliable choice for Hockey-puck-style Solid State Relays.  \nAvailable in a Wide Range of Currents.  \n• All models feature the same compact dimensions to provide a uniform mounting pitch.  \n• Built-in varistor effectively absorbs external surges.(except G3NA-D210B-UTU)  \n• Operation indicator enables monitoring operation.  \n• Protective cover for greater safety.  \n• Certified by UL, CSA, and TÜV.  \nRefer to Safety Precautions for All Solid State Relays.  \nModel Number Structure  \nFor the most recent information on models that have been certified for safety standards, refer to your OMRON website.  \nThe following models are scheduled to close the order at the end of March 2020.  \n• Models without \"-UTU\" (Not certified by TÜV)  \n• Models with rated input voltage \"AC 100-120\" and \"AC 200-240\".  \n■ Model Number Legend  \nG3NA-@@@@@-@ 1 2 3 4 5 6 7  \n1. Basic Model Name  \nG3NA: Solid State Relay  \n2. Load Power Supply  \nBlank: AC output  \nD: DC output  \n3. Rated Load Power Supply Voltage  \n2: 200 VAC or 200 VDC  \n4: 400 VAC  \n4. Rated Load Current  \nNote: Not all combinations of current and voltage are available.  \n05: 5 A  \n10: 10 A  \n20: 20 A  \n25: 25 A  \n40: 40 A  \n50: 50 A  \n75: 75 A  \n90: 90 A  \n5. Terminal Type  \nB: Screw terminals  \n6. Zero Cross Function  \nBlank: Equipped with zero cross function (AC-output models only)  \n7. Certification  \nUTU: Certified by UL, CSA, and TÜV  \nG3NA  \nOrdering Information  \n■ List of Models  \n\n| Isolation | Zero cross\u003Cbr>function | Indicator | Applicable output load\u003Cbr>(See note 1.) | Rated input\u003Cbr>voltage | Model |\n| --- | --- | --- | --- | --- | --- |\n| Phototriac | Yes | Yes | 5 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-205B-UTU DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-205B-UTU AC100-240 |\n| Phototriac |  |  | 10 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-210B-UTU DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-210B-UTU AC100-240 |\n| Phototriac |  |  | 20 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-220B-UTU DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-220B-UTU AC100-240 |\n| Phototriac |  |  | 25 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-225B-UTU DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-225B-UTU AC100-240 |\n| Phototriac |  |  | 40 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-240B-UTU DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-240B-UTU AC100-240 |\n| Phototriac |  |  | 50 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-250B-UTU DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-250B-UTU AC100-240 |\n| Phototriac |  |  | 75 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-275B-UTU-2 DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-275B-UTU-2 AC100-240 |\n| Phototriac |  |  | 90 A at 24 to 240 VAC (See note 2 .) | 5 to 24 VDC | G3NA-290B-UTU-2 DC5-24 |\n| Photocoupler |  |  |  | 100 to 240 VAC | G3NA-290B-UTU-2 AC100-240 |\n|  |  |  | 10 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-410B-UTU DC5-24 |\n|  |  |  |  | 100 to 240 VAC | G3NA-410B-UTU AC100-240 |\n|  |  |  | 20 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-420B-UTU DC5-24 |\n|  |  |  |  | 100 to 240 VAC | G3NA-420B-UTU AC100-240 |\n|  |  |  | 25 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-425B-UTU-2 DC5-24 |\n|  |  |  |  | 100 to 240 VAC | G3NA-425B-UTU-2 AC100-240 |\n|  |  |  | 40 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-440B-UTU-2 DC5-24 |\n|  |  |  |  | 100 to 240 VAC | G3NA-440B-UTU-2 AC100-240 |\n|  |  |  | 50 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-450B-UTU-2 DC5-24 |\n|  |  |  |  | 100 to 240 VAC | G3NA-450B-UTU-2 AC100-240 |\n|  |  |  | 75 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-475B-UTU-2 DC5-24 |\n|  |  |  |  | 100 to 240 VAC | G3NA-475B-UTU-2 AC100-240 |\n|  |  |  | 90 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-490B-UTU-2 DC5-24 |\n|  |  |  |  | 100 to 240 VAC | G3NA-490B-UTU-2 AC100-240 |\n|  | --- |  | 10 A at 5 to 200 VDC | 5 to 24 VDC | G3NA-D210B-UTU DC5-24 |\n|  |  | ","cbCaipO3nGvrcxV1","https://ap.wps.com/l/cbCaipO3nGvrcxV1","pdf",2689304,"English","# Key Features\n# Model Number Structure\n## Basic Model Name\n## Load Power Supply and Rated Voltage/Current\n## Terminal Type, Zero Cross Function, Certification\n# Ordering Information\n## List of Models\n# Accessories (Order Separately)\n## One-touch Mounting Plates\n## Heat Sinks\n## DIN-track Mounting\n## Screw Mounting\n# Specifications\n## Ratings","[{\"question\":\"What are the main features of the G3NA solid state relays?\",\"answer\":\"G3NA relays share compact uniform dimensions, include a built-in varistor for surge absorption (except the specified model), and offer an operation indicator for monitoring. A protective cover is also provided for safety.\"},{\"question\":\"How does the document describe the G3NA model number structure?\",\"answer\":\"The model number is decomposed into fields such as basic model name (G3NA), load power supply (AC/DC), rated load voltage and rated load current, terminal type, zero-cross function, and certification suffix (e.g., UTU).\"},{\"question\":\"What information is given in the ordering information section?\",\"answer\":\"The ordering section lists available models with isolation type, whether zero-cross function and indicator are included, applicable output load and rated input voltage ranges, plus notes about load conditions and loss time. It also indicates that order closure is scheduled for the end of March 2020 for specified model groups.\"}]","Solid State Relays - G3NA - Ordering Information, Model Number Structure, and Specifications | PDF",1791806604,48]