[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-664940-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-664940-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","solatube-330-ds-c-curb-cap-suspended-ceiling-technical-drawing","Solatube 330 DS-C - Curb Cap Suspended Ceiling Technical Drawing","","This document provides a detailed technical installation and assembly specification for the Solatube 330 DS-C (21-inch) Curb Cap system designed for suspended ceiling applications. It includes comprehensive engineering diagrams, cross-sectional views, and component identification labels such as the LightTracker reflector, dome assemblies, square-to-round transitions, and ceiling grid integration hardware. The documentation includes precise dimensional data in both imperial and metric units, material tolerances, and structural reference notes for installation. As an authoritative engineering schematic, it serves as a critical guide for contractors and installers to ensure proper alignment, clearance, and component sealing for natural daylighting systems. It outlines essential installation requirements, including the management of structural elements by others and necessary maintenance clearances of 6 inches from all plenum components.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/solatube-330-ds-c-curb-cap-suspended-ceiling-technical-drawing/664940/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/solatube-330-ds-c-curb-cap-suspended-ceiling-technical-drawing/664940.png","ImageObject",300,407,{"name":42,"@type":43},"Mia  ","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the minimum clearance required for the Solatube components?","Question",{"text":63,"@type":64},"A minimum clearance of 6 inches must be maintained from all Solatube components and other plenum components.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Are structural elements like plywood and rafters included with the Solatube system?",{"text":68,"@type":64},"No, structural elements such as plywood, rafters, and drywall are provided by others and are shown in the diagrams for reference only.",{"name":70,"@type":61,"acceptedAnswer":71},"What is the standard tolerance for angular measurements in this drawing?",{"text":72,"@type":64},"The specified angular tolerance for the components is ± 0.5°.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},664940,1793280194,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":30},687207024478,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","38.8  1 1/2\"  \n52   \n2\"  \nTYP.  \n692.8   \n27 1/4\"  \n27 1/4\"SQUARE OUTSIDE CAP REF.  \n571   \n22 1/2\"OPENING  \n535   \n21 1/8\"  \n8 7 6 5 4 3 2 1  \nF  \nE  \nD  \nC  \nB  \nA  \n38.81 1/2\"  \n330 DS DOME TUBE RING DOME SEAL DOME SPACER  \nDOME SCREW  \nROOFING SEALANT  \nFLASHING SCREW  \nROOFING  \nMATERIAL  \nSQUARE/ROUND  \nTRANSITION  \nT-BAR  \nCEILING  \nCEILING  \nTILE  \nDETAIL B  \nDETAIL A SCALE 3 : 1  \nSQUARE/ROUND TRANSITION V-CLIP  \nDIFFUSER  \nDIFFUSER FRAME  \n29611 5/8\"  \n52  \n2\"  \nTOP 0-45° ANGLE ADAPTER TUBE  \nEXTENSION TUBE  \nBOTTOM 0-45° ANGLE ADAPTER TUBE  \nB  \n686  \n27\"  \nMINIMUM INSIDE DIMENSION  \n575 Ø 22 5/8\"  \n 571   \n22 1/2\"OPENING  \n535   \n21 1/8\"  \n 571   \n22 1/2\"OPENING  \n535   \n21 1/8\"  \nC  \nSOLATUBE 330 DS-C (21 IN / 530 MM) CURB CAP SUSPENDED CEILING  \n 78.9  \n3 1/8\"  \nTYP.  \n 78.5  \n3 1/8\"  \nTYP.  \n8X FASTENERS  \nLIGHTTRACKER REFLECTOR  \nCURB BY  \nOTHERS  \nROOF RAFTER  \nOPTIONAL NATURAL EFFECTS LENS  \nLENS RETAINER RING  \nLENS  \nSEAL  \n 692.8  \n 691.427 1/4\"SQUARE OUTSIDE CAP  \nREF.  \nTOP VIEW SCALE 1:1  \nF  \nE  \nD  \nC  \nTRANSITION BOX  \nLENS TAB  \nDETAIL C SCALE 3 : 1  \nNOTES:  \n1. STRUCTURAL ELEMENTS (PLYWOOD, RAFTERS, DRYWALL ETC.) BY OTHERS & SHOWN FOR REFERENCE ONLY.  \n2. ALL TUBE JOINTS & SEAMS TAPED WITH 2\" FOIL TAPE (NOT SHOWN). B  \n3. DIMENSIONS IN BRACKETS ARE METRIC UNLESS OTHERWISE SPECIFIED.  \n4. 6\" MIN CLEARANCE SHOULD BE MAINTAINED FROM ALL SOLATUBE COMPONENTS AND OTHER PLENUM COMPONENTS.  \nUNLESS OTHERWISE SPECIFIED:  \nDIMENSIONS ARE IN INCHES TOLERANCES:  \nANGULAR: ± 0.5°  \n.X ± . 1  \n.XX ± .02  \n.XXX ± .005 MATERIAL  \n- -  \nSOLATUBE INTERNATIONAL, INC.  \nCOPYRIGHT 2011  \nWWW.SOLATUBE.COM  \nTITLE:  \nDRAWN BY  \nSTEVENS  \nDATE  \n3/11/09  \n330 DS (21\") CURB CAP SUSPENDED CEILING  \nA  \nSCALE 3 : 1 FULL SECTION  \nSCALE 1:1  \n- -  \nFINISH  \n- -  \nDO NOT SCALE DRAWING  \nCHECKED BY  \n- -  \nAPPROVED BY  \n- -  \nDATE  \n- -  \nDATE  \n- -  \nSIZE  \nDWG. NO. REV  \nWEB-330-CF-SC   \nSCALE: 1:1 SHEET 1 OF 1  \n8 7 6 5 4 3 2 1","cbCaiewXIMuUb8fL","https://ap.wps.com/l/cbCaiewXIMuUb8fL","pdf",282023,"English","# Assembly Components and Specifications\n## Installation Notes and Dimensions","[{\"question\":\"What is the minimum clearance required for the Solatube components?\",\"answer\":\"A minimum clearance of 6 inches must be maintained from all Solatube components and other plenum components.\"},{\"question\":\"Are structural elements like plywood and rafters included with the Solatube system?\",\"answer\":\"No, structural elements such as plywood, rafters, and drywall are provided by others and are shown in the diagrams for reference only.\"},{\"question\":\"What is the standard tolerance for angular measurements in this drawing?\",\"answer\":\"The specified angular tolerance for the components is ± 0.5°.\"}]","Solatube 330 DS-C - Curb Cap Suspended Ceiling Technical Drawing | PDF"]