[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646883-105":59,"doc-detail-646883-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","smoke-alarm-users-manual-photoelectric-smoke-alarm-hush-feature-model-vst-s588h","Smoke Alarm User’s Manual - PHOTOELECTRIC SMOKE ALARM (“HUSH” FEATURE) - MODEL: VST-S588H","","Photoelectric smoke alarm user manual for model VST-S588H, detailing the HUSH/Test feature and core functions such as DC operation, high sensitivity, LED status indicator, tamper-resist mounting, and extra-loud alarm sound over 85 dB. Provides technical specifications including power source (9V DC battery), detection type (photoelectric chamber), operating temperature and humidity ranges, and alarm sound level. Includes extensive safety instructions on correct battery use, weekly testing, limitations of smoke detection, placement rules for single-room and multi-level homes, and guidance for minimizing nuisance alarms.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/smoke-alarm-users-manual-photoelectric-smoke-alarm-hush-feature-model-vst-s588h/646883/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/smoke-alarm-users-manual-photoelectric-smoke-alarm-hush-feature-model-vst-s588h/646883.png","ImageObject",300,407,{"name":92,"@type":93},"Damian","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-12","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What conditions can prevent the smoke alarm from working properly?","Question",{"text":112,"@type":113},"It requires a constant working 9-volt battery. The alarm will not work if DC power is not connected or has failed, or if the battery is removed, drained, or improperly connected, and it must use only the specified battery type.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should the smoke alarm be tested and how often?",{"text":117,"@type":113},"Use the Test button, which accurately tests all alarm functions. Test the smoke alarm weekly to ensure proper operation.",{"name":119,"@type":110,"acceptedAnswer":120},"Where should smoke alarms be installed in a home?",{"text":121,"@type":113},"For single-family residences, place at least one unit on every floor and in every sleeping area/bedroom, and consider additional locations in halls, storage areas, and finished attics. Install alarms at key positions such as near sleeping areas and at the top of the first-to-second floor stairway, following local requirements and the recommended diagram.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646883,1792929679,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":4},137451208677,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Smoke Alarm User’s Manual  \nPlease read and save this manual  \nPHOTOELECTRIC SMOKE ALARM（“HUSH”FEATURE）  \nMODEL: VST-S588H  \n Class II Apparatus  \nPhotoelectric smoke alarms are generally more effective at detecting smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding.  \nMAIN FEATURES  \n􀀁 DC operated photoelectric type smoke alarm  \n􀀁 Photoelectric sensor for slow smoldering fires  \n􀀁 Hush /Test feature  \n􀀁 Non-radioactive technology for environmental friendly  \n􀀁 High and stable sensitivity  \n􀀁 Quick fix mounting bracket for easy installation  \n􀀁 Fitting and battery tamper-resist feature  \n􀀁 LED operation indicator  \n􀀁 Extra loud alarm sound over 85 dB  \n􀀁 Low-battery and battery missing warning indicator  \n􀀁 Auto-reset when smoke clears  \nSPECIFICATION  \n􀀁 Model Number: VST-S588H  \n􀀁 Detection Type: Photoelectric Chamber  \n􀀁 Power Source: 9V DC Battery  \n􀀁 Standby Current: 15uA max  \n􀀁 Alarm Current: 30mA max  \n􀀁 Alarm Sound Level 85 Decibels at 3 meters  \n􀀁 Operation Temperature: 5℃to 45℃  \n􀀁 Ambient Humidity: 10%-90%  \n􀀁 Sensitivity to Smoke: 3.0-6.0 %Obs /m  \n􀀁 Compact size: 110mm diameter  \nIMPORTANT SAFETY INFORMATION  \n1. This smoke alarm requires constant working 9-volt battery to operate properly. This smoke alarm WILL NOT work if DC power is not connected or has failed or been interrupted for any reason AND the battery is removed, drained or improperly connected. DO NOT use any other kind of battery except as specified. DO NOT connect this smoke alarm to any other typeof smoke alarm or auxiliary device. It is designed as a stand alone unit.  \n2. DO NOT connect this smoke alarm to any other type of smoke alarm or auxiliary device, except those listed this manual. The Test button accurately tests all smoke alarm functions. Do not use any other test method. Test smoke alarm weekly to ensure proper operation.  \n3. DO NOT remove or disconnect battery to quiet unwanted alarms. This will remove your protection. Open windows or fan the air around smoke alarm to silence it.  \n4. Observe and follow all local and national electrical and building codes for installation.  \n5 . This smoke alarm is designed to be used inside a single room only. In multi-room buildings, each individual living unit should have its own smoke alarms. Do not install in non-residential buildings. And this smoke alarm is not a substitute for a complete alarm system.  \n6. Smoke may not reach the smoke alarm for many reasons. For example, if a fire starts in a remote part of the home, on another level, in a chimney, wall, roof, or on the other side of a closed door, smoke may not reach the smoke alarm in time to alert household members. A smoke alarm will not promptly detect a fire except in the area or room in which it is installed.  \n7 . Smoke alarms may not alert every household member every time. The alarm sound is loud in order to alert individuals to a potential danger. However, there may be limiting circumstances where a household member may not hear the alarm (i.e. outdoor or indoor noise, sound sleepers, drug or alcohol usage, the hard of hearing, etc.) . If you suspect that this smoke alarm may not alert a household member, install and maintain specialty smoke alarms. Household member must hear the alarm’s warning sound and quickly respond to it to reduce the risk of damage, injury, or death that may result from fire. If a household member is hearing impaired, install special smoke alarms with lights or vibrating devices to alert occupants.  \n8. Smoke alarms can only sound their alarms when they detect smoke. Smoke alarms detect combustion particles in the air. They do not sense heat, flame, or gas. This smoke alarm is designed to give audible warning of a developing fire. However, many fires are fast-burning, explosive, or intentional. Others are caused by carelessness or safety hazards. Smoke may not reach the smoke alarm QUICKLY ENOUGH to ensure safe es","cbCaiiO7e2KBUPUT","https://ap.wps.com/l/cbCaiiO7e2KBUPUT","pdf",642133,"English","# Smoke Alarm User’s Manual\n## Main Features\n## Specification\n## Important Safety Information\n## Recommended Locations for Smoke Alarms\n## Important Smoke Alarm Placement and Exception Information","[{\"question\":\"What conditions can prevent the smoke alarm from working properly?\",\"answer\":\"It requires a constant working 9-volt battery. The alarm will not work if DC power is not connected or has failed, or if the battery is removed, drained, or improperly connected, and it must use only the specified battery type.\"},{\"question\":\"How should the smoke alarm be tested and how often?\",\"answer\":\"Use the Test button, which accurately tests all alarm functions. Test the smoke alarm weekly to ensure proper operation.\"},{\"question\":\"Where should smoke alarms be installed in a home?\",\"answer\":\"For single-family residences, place at least one unit on every floor and in every sleeping area/bedroom, and consider additional locations in halls, storage areas, and finished attics. Install alarms at key positions such as near sleeping areas and at the top of the first-to-second floor stairway, following local requirements and the recommended diagram.\"}]","Smoke Alarm User’s Manual - PHOTOELECTRIC SMOKE ALARM (“HUSH” FEATURE) - MODEL: VST-S588H | PDF",1792773191,15]