[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-646884-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-646884-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","smoke-alarm-users-manual-model-9120-introduction-fire-safety-tips","Smoke Alarm User’s Manual - Model 9120 - Introduction - Fire Safety Tips","","User’s manual for an AC powered First Alert smoke alarm (models 9120 and 9120B) detailing operation, installation, features, and safety guidance. Covers smart nuisance-alarm reduction, single-button test/silence behavior, and the latching alarm indicator. Explains weekly testing, regular maintenance, indicator and horn patterns, recommended mounting practices, and what to do when the alarm sounds. Includes fire safety tips and limitations, emphasizing early warning only and that it does not detect gas, heat, or flame.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/smoke-alarm-users-manual-model-9120-introduction-fire-safety-tips/646884/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/smoke-alarm-users-manual-model-9120-introduction-fire-safety-tips/646884.png","ImageObject",300,407,{"name":42,"@type":43},"AfterMidnight","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-07","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What does the smoke alarm do and what are its limits?","Question",{"text":63,"@type":64},"The alarm monitors air and triggers when smoke reaches its sensing chamber, providing early warning. It only works if installed, maintained, and positioned so smoke can reach it, and it cannot sense gas, heat, or flame or prevent or extinguish fires.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How do you use the test and silence feature?",{"text":68,"@type":64},"Single-button test/silence provides different functions depending on the alarm mode: testing, silencing, re-testing after silencing, and clearing the latching feature when in silence.",{"name":70,"@type":61,"acceptedAnswer":71},"What actions should be taken if the smoke alarm sounds?",{"text":72,"@type":64},"When it sounds, treat it as a potential fire situation and follow the manual’s guidance for what to do in case of fire, including escape planning. The manual also highlights keeping a working fire extinguisher and reliable means of escape on upper floors.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},646884,1792929319,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":55,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":4},962090896061,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| \u003Cbr>USER’S MANUAL Smoke Alarms\u003Cbr>|\n| --- |\n| \u003Cbr>AC Powered Ionization Smoke Alarm with Silence and Latching Features\u003Cbr>Model 9120\u003Cbr>Input: 120V AC ~, 60 Hz, 0.04A\u003Cbr>AC Powered Ionization Smoke Alarm with Battery Back-up, Silence and Latching Features Model 9120B\u003Cbr>Input: 120V AC ~, 60 Hz, 0.04A\u003Cbr>Printed in Mexico\u003Cbr>M08-0134-003 K1 04/07\u003Cbr>\u003Cbr>Models 9120\u003Cbr>9120B |\n\nIMPORTANT! PLEASE READ CAREFULLY AND SAVE  \nThis user’s manual contains important information about your Smoke Alarm’s operation. If you are installing the Smoke Alarm for use by others, you must leave this manual—or a copy of it—with the end user.  \nTABLE OF CONTENTS  \nIntroduction .................................................1  \nFire Safety Tips ..............................................1  \nBefore You Install This Smoke Alarm ..........................1-2  \nHow To Install This Smoke Alarm .............................2-3  \nOptional Locking Features .....................................4  \nUnderstanding the Indicator Lightsand Alarm Horn Patterns ......................................5  \nWeekly Testing ...............................................5  \nRegular Maintenance .........................................5  \nIf This Smoke Alarm Sounds ...................................5  \nWhat To Do In Case Of Fire ....................................5  \nUsing the Silence Feature .....................................5  \n“Latching Alarm” Indicator ....................................6  \nIf You Suspect a Problem ......................................6  \nAll First Alert® and BRK® Smoke Alarms conform to regulatory requirements, including UL217 and are designed to detect particles of combustion. Smoke particles of varying number and size are produced in all fires.  \nIonization technology is generally more sensitive than photoelectric technology at detecting small particles, which tend to be produced  \nin greater amounts by flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or a grease fire in the kitchen.  \nPhotoelectric technology is generally more sensitive than ionization technology at detecting large particles, which tend to be produced in  \ngreater amounts by smoldering fires, which may smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding.  \nFor maximum protection, use both types of Smoke Alarms on each level and in every bedroom of your home.  \nRecommended Locations For Smoke Alarms .....................6  \nLocations To Avoid For Smoke Alarms .........................6-7  \nAbout Smoke Alarms .........................................7  \nSpecial Compliance Considerations .............................7  \nLimitations of Smoke Alarms ...................................7  \nLimited Warranty .............................................7  \n© 2007 BRK Brands, Inc. , a subsidiary of Jarden Corporation. 3901 Liberty Street Road, Aurora, IL 60504-8122  \nAll rights reserved. Consumer Affairs: (800) 323-9005  \n[www.brkelectronics.com](www.brkelectronics.com) • [www.firstalert.com](www.firstalert.com)  \nINTRODUCTION  \nThank you for choosing BRK Brands, Inc. for your Smoke Alarm needs. You have purchased a state-of-the-art Smoke Alarm designed to provide you with early warning of a fire.  \nKey features include:  \nSmart Technology designed to help reduce unwanted or nuisance alarms. Single Button Test/Silence eliminates confusion. Depending on what mode the alarm is in, pushing the button provides different functions such as testing the alarm, silencing the alarm, re-testing the alarm when in silence and clearing the Latching feature.  \nLatching Alarm Indicator easily identifies initiating alarm even after the alarm condition has subsided.  \nPerfect Mount System includes a gasketless base for easy installation anda new mounting bracket that keeps the alarm secure over a wide rotation range to allow for per","cbCaibTZUxGzHlZR","https://ap.wps.com/l/cbCaibTZUxGzHlZR","pdf",2159762,"English","# Introduction\n## Fire Safety Tips\n## Before You Install This Smoke Alarm\n## How To Install This Smoke Alarm\n## Optional Locking Features\n## Understanding the Indicator Lights and Alarm Horn Patterns\n## Weekly Testing\n## Regular Maintenance\n## If This Smoke Alarm Sounds\n## What To Do In Case Of Fire\n## Using the Silence Feature\n## “Latching Alarm” Indicator\n## If You Suspect a Problem","[{\"question\":\"What does the smoke alarm do and what are its limits?\",\"answer\":\"The alarm monitors air and triggers when smoke reaches its sensing chamber, providing early warning. It only works if installed, maintained, and positioned so smoke can reach it, and it cannot sense gas, heat, or flame or prevent or extinguish fires.\"},{\"question\":\"How do you use the test and silence feature?\",\"answer\":\"Single-button test/silence provides different functions depending on the alarm mode: testing, silencing, re-testing after silencing, and clearing the latching feature when in silence.\"},{\"question\":\"What actions should be taken if the smoke alarm sounds?\",\"answer\":\"When it sounds, treat it as a potential fire situation and follow the manual’s guidance for what to do in case of fire, including escape planning. The manual also highlights keeping a working fire extinguisher and reliable means of escape on upper floors.\"}]","Smoke Alarm User’s Manual - Model 9120 - Introduction - Fire Safety Tips | PDF",1792773194,18]