[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-564551-105":59,"doc-detail-564551-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","simultaneous-determination-of-1-naphthol-and-2-naphthol-in-waters-electrochemical-sensor-based-on-magnetite-porous-reduced-graphene-oxidecarbon-nanotube-hybrid","Simultaneous Determination of 1-Naphthol and 2-Naphthol in Waters - Electrochemical Sensor Based on Magnetite Porous Reduced Graphene Oxide/Carbon Nanotube Hybrid","","Waste aqueous solutions containing naphthol are addressed using physical and chemical treatments, yet naphthols pose significant risks to environmental quality and human health. A simple, cost-effective electrochemical sensor is developed using a magnetite (Fe3O4) porous reduced graphene oxide/carbon nanotube hybrid (Fe3O4@prGO-CNT) nanocomposite for simultaneous detection of 1-naphthol and 2-naphthol. Voltammetric and differential pulse voltammetric behavior shows an ~200 mV potential separation enabling binary-mixture quantification. Under optimized conditions, linear ranges for 1-naphthol and 2-naphthol are 0.5–30 μM and 0.7–40 μM, with detection limits (S/N=3) of 76 and 82 nM, respectively, and satisfactory responses in wastewaters and river waters.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/simultaneous-determination-of-1-naphthol-and-2-naphthol-in-waters-electrochemical-sensor-based-on-magnetite-porous-reduced-graphene-oxidecarbon-nanotube-hybrid/564551/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/simultaneous-determination-of-1-naphthol-and-2-naphthol-in-waters-electrochemical-sensor-based-on-magnetite-porous-reduced-graphene-oxidecarbon-nanotube-hybrid/564551.png","ImageObject",300,407,{"name":92,"@type":93},"Guten tag","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-17","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Why is simultaneous detection of 1-naphthol and 2-naphthol important?","Question",{"text":113,"@type":114},"Naphthol isomers often coexist due to similar structures and physicochemical properties. Simultaneous detection is important for effective environmental analysis and management because both compounds are toxic to human health and the environment.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the proposed sensor distinguish between the two naphthols?",{"text":118,"@type":114},"The Fe3O4@prGO-CNT nanocomposite on a carbon paste electrode produces voltammetric responses with a large potential separation of about 200 mV between 1-naphthol and 2-naphthol, enabling simultaneous determination from a binary mixture.",{"name":120,"@type":111,"acceptedAnswer":121},"What are the analytical performance results under optimized conditions?",{"text":122,"@type":114},"The sensor shows linear relationships for 1-naphthol in the 0.5–30 μM range and for 2-naphthol in the 0.7–40 μM range. Detection limits (S/N=3) are 76 nM for 1-naphthol and 82 nM for 2-naphthol, with satisfactory performance in wastewaters and river waters.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},564551,1792253525,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},687212321768,"https://ap-avatar.wpscdn.com/avatar/a0010bdbe886d2fe77?x-image-process=image/resize,m_fixed,w_180,h_180&k=1789897067658708522","ISSN 1023-1935, Russian Journal of Electrochemistry, 2023, Vol. 59, No. 12, pp. 1138–1150. © Pleiades Publishing, Ltd., 2023.  \nSimultaneous Determination of 1-Naphtholand 2-Naphtholin Waters by Electrochemical Sensor Based on Magnetite Porous Reduced Graphene Oxide/Carbon Nanotube Hybrid  \nSeyed Hosein Seyedia, Seyed-Ahmad Shahidia, *, Fereshteh Chekinb, **,  \nAzade Ghorbani-HasanSaraeia, and Mohammad Bagher Limooeic  \na Department of Food Science and Technology, Ayatollah Amoli Branch, Islamic Azad University, Amol, Iran b Department of Chemistry, Ayatollah Amoli Branch, Islamic Azad University, Amol, Iran c Department of Materials Science and Engineering, Ayatollah Amoli Branch, Islamic Azad University, Amol, Iran  \n*[e-mail: sashahidy@yahoo.com](e-mail: sashahidy@yahoo.com)  \n**[e-mail: fchekin@yahoo.com](e-mail: fchekin@yahoo.com)  \nReceived February 9, 2023; revised May 30, 2023; accepted June 2, 2023  \nAbstract—The waste aqueous solutions containing naphthol are treated by physical and chemical methods.  \nHowever, naphthols are toxic to environment and human health. So it is very important to simultaneously detect them, will make contributions to both the manufacture and the environment management. Herein we developed a simple, cost effective, electrochemical sensor based on magnetite (Fe3O4 nanoparticles) porous reduced graphene oxide/carbon nanotubes (Fe3O4@prGO-CNT) nanocomposite for simultaneous detection of 1-naphthol and 2-naphthol. Voltammetric responses suggest dramatical improvement of electrocatalytic properties of naphthols by incorporating Fe3O4@prGO-CNT on carbon paste electrode (CPE) . Differential pulse voltammetric (DPV) measurement depicts large potential separation of about 200 mV between naphthols, allows their simultaneous determination from binary mixture. Under optimized condition, Fe3O4@prGO-CNT/CPE manifested linear relationships of 1-naphthol and 2-naphthol inthe range of 0.5– 30 and 0.7–40 μM with detection limit (S/N = 3) of 76 and 82 nM respectively. Moreover, Fe3O4@prGOCNT/CPE showed satisfactory response towards wastewaters and river waters for determining 1-naphtholand 2-naphthol concentrations.  \nKeywords: naphthols, porous reduced graphene oxide, Fe3O4 nanoparticles, electrochemical sensor  \nDOI: 10.1134/S1023193523220056  \nINTRODUCTION  \nThe kind of organic materials and intermadiates, naphthols (1-naphthol and 2-naphthol) are widely used in the industrial production [1] . 1-Naphthol is widely used as the raw material in the manufacture of dyes and insecticides, and is also a secondary product of chemical, paint, paper, and pesticide industries. In addition, it is a kind of phenolic compound with high toxicity and thus has a profound effect on the environment and health of people [2, 3]. 2-Naphthol is widely used in pharmaceutical and dye industries in production of antirheumatic naproxen and azo-dyes, but on the other hand, it is a toxic compound and its disposal causes remarkable environment pollutions [4, 5] . Actually, waste aqueous solutions containing 2-naphthol are treated by physical and chemical methods or electrochemical procedure [6] . However, naphthols are also toxic to environment and human health [7] . So it is very important to simultaneously detect them,  \nwill make contributions to both the manufacture and the environment management. Importantly, due to their similar structures and physicochemical properties, naphthol isomers usually coexist. The simultaneous determination of naphthol isomers has become a challenge in environmental analysis. So far, several analytical methods such as chromatography and spectroscopy for the simultaneous determination of naphthol isomers have been reported. However, these methods generally require complicated procedures, long measuring time and complex operation, leading to inconvenience in practice [8–10] . Therefore, the development of a simple, rapid, reliable, selective and sensitive method for the specific recognition of naphthol st","cbCaiuBG9c5fqaGl","https://ap.wps.com/l/cbCaiuBG9c5fqaGl","pdf",1570626,13,"English","# Introduction\n## Background and significance of naphthol detection\n## Electrochemical approaches and literature gaps","[{\"question\":\"Why is simultaneous detection of 1-naphthol and 2-naphthol important?\",\"answer\":\"Naphthol isomers often coexist due to similar structures and physicochemical properties. Simultaneous detection is important for effective environmental analysis and management because both compounds are toxic to human health and the environment.\"},{\"question\":\"How does the proposed sensor distinguish between the two naphthols?\",\"answer\":\"The Fe3O4@prGO-CNT nanocomposite on a carbon paste electrode produces voltammetric responses with a large potential separation of about 200 mV between 1-naphthol and 2-naphthol, enabling simultaneous determination from a binary mixture.\"},{\"question\":\"What are the analytical performance results under optimized conditions?\",\"answer\":\"The sensor shows linear relationships for 1-naphthol in the 0.5–30 μM range and for 2-naphthol in the 0.7–40 μM range. Detection limits (S/N=3) are 76 nM for 1-naphthol and 82 nM for 2-naphthol, with satisfactory performance in wastewaters and river waters.\"}]","Simultaneous Determination of 1-Naphthol and 2-Naphthol in Waters - Electrochemical Sensor Based on Magnetite Porous Reduced Graphene Oxide/Carbon Nanotube Hybrid | PDF",1791842807,33,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-18/815cb89847254ecedb21bf7144bd5250.webp",983,1272,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-18/75029f650b706eb3532f6bcebc11fa5e.webp",982,1270,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-18/a04980ec04aad443c4d1492fb266e704.webp",981,1269,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-18/b8af66c19c4f2b549d28049340cdd02c.webp",980,1268]