[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-459999-105":59,"doc-detail-459999-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","simulation-study-of-a-hyperbolic-linear-ion-trap-with-asymmetric-curvature-radii-research-paper","Simulation Study of a Hyperbolic Linear Ion Trap with Asymmetric Curvature Radii - Research Paper","","Linear ion traps (LITs) with simplified geometries can support miniaturized mass spectrometry, but geometric simplification often produces nonlinear higher-order fields that degrade performance. This study examines asymmetric hyperbolic electrode modifications to mitigate the intrinsic 50% detection-efficiency limit in miniaturized LITs from bidirectional ion ejection. Numerical simulations evaluate an asymmetric design using independent curvature-radius and bending-angle adjustments, confirming odd-order multipole incorporation and showing ~90% single-side ion ejection efficiency when combining odd and even multipole fields.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/simulation-study-of-a-hyperbolic-linear-ion-trap-with-asymmetric-curvature-radii-research-paper/459999/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/simulation-study-of-a-hyperbolic-linear-ion-trap-with-asymmetric-curvature-radii-research-paper/459999.png","ImageObject",300,407,{"name":92,"@type":93},"Aran","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-27","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What problem does the study address in miniaturized linear ion traps?","Question",{"text":113,"@type":114},"Miniaturized LITs often suffer from a detection-efficiency ceiling of about 50% because ions are ejected bidirectionally when using a single detector.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How is asymmetry introduced in the proposed hyperbolic linear ion trap design?",{"text":118,"@type":114},"Asymmetry is created by independently adjusting vertex curvature radii and bending angles in opposing x-direction electrodes to form an asymmetric trapping field.",{"name":120,"@type":111,"acceptedAnswer":121},"What do the simulations and results indicate about ion ejection efficiency?",{"text":122,"@type":114},"Field analysis confirms odd-order multipole components, and experimental results show approximately 90% ion ejection efficiency from a single trap side when combining higher-order odd and even multipole fields.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},459999,1790987901,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},137455076865,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","ACS Partner Journal  \nThis article is licensed under CC-BY-NC-ND 4.0  \n[pubs.acs.org/jasms](pubs.acs.org/jasms)  Article   \nSimulation Study of a Hyperbolic Linear Ion Trap with Asymmetric Curvature Radii  \nYang Li, Yuanjiang Luo, Lingwen Kong, Jiahuan Hao, Pingyan Wei, Lei Xia, Yawei Liu, Qiangling Zhang, Chengyin Shen, Chaoqun Huang, * and Yannan Chu  \n Cite This: J. Am. Soc. Mass Spectrom. 2026, 37, 216−225  \nRead Online  \n\n|  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| ACCESS   | Metrics & More |  |  Article Recommendations |  | *sı Supporting Information |\n\nABSTRACT: Linear ion traps (LITs) with simplified geometries have shown potential for miniaturized mass spectrometry systems, though structural simplifications often introduce nonlinear higher-order fields that compromise performance. This study investigates asymmetric hyperbolic electrode modifications to address the inherent 50% detection efficiency limitation in miniaturized LITs caused by bidirectional ion ejection. The research employed numerical simulations to evaluate a geometrically modified LIT design. Electrode asymmetry was introduced through independent adjustments of vertex curvature radii and bending angles in opposing xdirection electrodes, creating an asymmetric trapping field. Structural optimization involved initial x-axis elongation of acentrosymmetric ion trap followed by controlled geometric modifications. Field analysis confirmed the incorporation of odd-order multipole components through these adjustments. Experimental results demonstrated approximately 90% ion ejection efficiency from a single trap side when combining higher-order odd and even multipole fields. This work provides valuable insights into the design of asymmetric ion traps, offering a practical solution for high-performance portable MS development.  \nKEYWORDS: linear ion trap, theoretical simulation, mass resolution, mass spectrometry  \n1. INTRODUCTION  \nMass spectrometers, which perform ionization, separation, and detection of ions under high vacuum conditions, have been widely employed in chemistry and biotechnology owing to their exceptional capabilities in trace analysis.1 However, the broader application of conventional mass spectrometers has been constrained by their large size, high power consumption, and the need for sample pretreatment. In contrast, miniaturized ion trap analyzers, which can function effectively at higher pressures, facilitate tandem mass spectrometry, and are easily miniaturized, have emerged as optimal mass analyzers for portable instrumentation.2 These devices are increasingly critical in fields such as food safety,3 public security,4 quality control,5 environmental monitoring,6 life sciences,7 and aerospace and military technologies.8  \nAlthough three-dimensional (3D) ion traps9 and linear ion traps (LITs)10 are widely used in commercial ion trap mass spectrometers, their hyperbolic electrode structures require  \nhigh manufacturing precision (with micrometer-level tolerances), leading to elevated costs and challenges in fabrication and assembly. These limitations have impeded their widespread adoption and miniaturization. To address the demand for portability and cost reduction, recent research has focused on simplifying LIT electrode designs, spurring the development of novel LITs with simpler geometries.11, 12 For instance, the cylindrical ion trap (CIT) 13 and rectangular ion trap (RIT) 14 substantially reduced manufacturing complexity and were successfully integrated into miniature mass spectrometers. Subsequently, various structurally simplified LITs have been  \n\n| Received: September 13, 2025\u003Cbr>Revised: November 6, 2025\u003Cbr>Accepted: December 2, 2025\u003Cbr>Published: December 16, 2025 | |\n| --- | --- |\n\n© 2025 The Authors. Published by American Chemical Society  \n216  \n[https://doi.org/10.1021/jasms.5c00307](https://doi.org/10.1021/jasms.5c00307)[ ](https://doi.org/10.1021/jasms.5c00307)J. Am. Soc. Mass Spectrom. 2026, 37, 216−225  \nFig","cbCaifDI11AMXGrx","https://ap.wps.com/l/cbCaifDI11AMXGrx","pdf",3703668,"English","# Abstract\n# Introduction\n## Miniaturized mass spectrometry and ion traps\n## Limitations of simplified LIT geometries\n## Bidirectional ejection and detection efficiency constraints\n## Motivation for odd-order multipole fields","[{\"question\":\"What problem does the study address in miniaturized linear ion traps?\",\"answer\":\"Miniaturized LITs often suffer from a detection-efficiency ceiling of about 50% because ions are ejected bidirectionally when using a single detector.\"},{\"question\":\"How is asymmetry introduced in the proposed hyperbolic linear ion trap design?\",\"answer\":\"Asymmetry is created by independently adjusting vertex curvature radii and bending angles in opposing x-direction electrodes to form an asymmetric trapping field.\"},{\"question\":\"What do the simulations and results indicate about ion ejection efficiency?\",\"answer\":\"Field analysis confirms odd-order multipole components, and experimental results show approximately 90% ion ejection efficiency from a single trap side when combining higher-order odd and even multipole fields.\"}]","Simulation Study of a Hyperbolic Linear Ion Trap with Asymmetric Curvature Radii - Research Paper | PDF",1790757465,25,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d3efcf6bad194b0ac6b39a114357cfb1.webp",983,1296,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c0504db2f0fb8bbfe60ae6abde566d1d.webp",982,1295,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/61fd9aea35e8e5fd73357ed7da5fccba.webp",981,1293,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6f1c776a99abddd7447e2c54951eb517.webp",980,1292]