[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-457846-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-457846-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","shortening-breath-hold-durations-in-breast-radiotherapy-a-novel-time-control-strategy-for-deep-inspiration-breath-hold-vmat","Shortening breath-hold durations in breast radiotherapy - a novel time-control strategy for deep inspiration breath-hold VMAT","","Study proposes a novel time-control optimization strategy for Deep Inspiration Breath-Hold (DIBH) breast radiotherapy, addressing routine VMAT arc delivery times that often exceed patients’ comfortable breath-hold capacity (~20 s). The approach targets reduced overall delivery time and improved temporal uniformity across arcs on the UIH uTPS platform, evaluating delivery bottlenecks via bounding factor analysis of gantry rotation, MLC motion, and MU delivery.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/shortening-breath-hold-durations-in-breast-radiotherapy-a-novel-time-control-strategy-for-deep-inspiration-breath-hold-vmat/457846/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/shortening-breath-hold-durations-in-breast-radiotherapy-a-novel-time-control-strategy-for-deep-inspiration-breath-hold-vmat/457846.png","ImageObject",300,407,{"name":42,"@type":43},"ahduag","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-08","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem does the study address in DIBH breast radiotherapy VMAT plans?","Question",{"text":63,"@type":64},"Single VMAT delivery times for a breath-hold often exceed the patient’s comfortable DIBH capacity (~20 s), and time delays can reduce real-time tracking accuracy during SGRT.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How many patients and VMAT plan combinations were evaluated?",{"text":68,"@type":64},"The study included 32 left-sided breast cancer patients and generated 16 distinct VMAT plans per patient to compare optimization algorithms (FMO/SPO), fluence modes (FF/FFF), and dose rates.",{"name":70,"@type":61,"acceptedAnswer":71},"What did the bounding factor analysis reveal about delivery limitations?",{"text":72,"@type":64},"FMO plans were mainly limited by MLC movement, while SPO plans were mainly limited by MU delivery; applying the strategy affected time and dosimetric quality differently across plan types.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},457846,1790870333,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":112,"preview_page_count":33,"preview_urls":145},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Chen et al. Radiation Oncology (2026) 21:7 [https://doi.org/10.1186/s13014-025-02766-w](https://doi.org/10.1186/s13014-025-02766-w)  \nRadiation Oncology  \nRESEARCH Open Access  \nShortening breath-hold durations in breast radiotherapy: a novel time-control strategy for deep inspiration breath-hold VMAT  \nShilin Chen 1,2,3,4,5, Weigang Hu 1,3,4,5, Jiazhou Wang 1,3,4,5* and Yao Xu 1,3,4,5*  \nAbstract  \nBackground To address the issue where single Volumetric Modulated Arc Therapy (VMAT) delivery times often exceed a patient’s comfortable breath-hold capacity of approximately 20s during Deep Inspiration Breath-Hold (DIBH) radiotherapy for breast cancer, this study proposes and systematically evaluates a novel time-control optimization strategy. The goal is to reduce overall delivery time and improve temporal uniformity across individual arcs within the United Imaging Healthcare (UIH) uTPS platform.  \nMethods The study included 32 left-sided breast cancer patients, with 16 having undergone breast-conserving surgery and 16 having undergone mastectomy. For each patient, 16 distinct VMAT plans were generated to compare combinations of optimization algorithms (FMO/SPO), fluence modes (FF/FFF), and various dose rates. A novel bounding factor analysis was introduced to quantify delivery bottlenecks by assessing the relative contributions of gantry rotation, MLC movement, and MU delivery to the overall treatment time.  \nResults The time-control strategy effectively reduced the mean arc delivery time and improved its uniformity across all tested combinations. The bounding factor analysis revealed that FMO plans were primarily limited by Multi  \nLeaf Col limator (MLC) movement, whereas SPO plans were predominantly limited by Monitor Unit (MU) delivery. Consequently, when the time-control strategy was applied to FMO plans, it shortened delivery times by restricting MLC mobility, which led to some dosimetric degradation. In contrast, for SPO plans, the strategy maintained or enhanced MLC movement while significantly reducing time, thus preserving or even improving dosimetric quality. Notably, the combination of SPO with the high-dose-rate (1400 MU/min) FFF mode reduced single-arc delivery times to approximately 10s.  \nConclusions The proposed time-control strategy is a superior solution for shortening delivery time and enhancing patient comfort without significant dosimetric compromise.  \nKeywords Time control, DIBH, VMAT, Bounding factor, FMO, SPO, FFF, MLC, UIH  \n*Correspondence: Jiazhou Wang [wjiazhou@gmail.com](wjiazhou@gmail.com)[ ](wjiazhou@gmail.com)Yao Xu [yaoxu@mail.ustc.edu.cn](yaoxu@mail.ustc.edu.cn)  \n1Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai 200032, China  \n2Department of Radiation Oncology, Fudan University Shanghai Cancer Center Xiamen Hospital, Xiamen 361000, China  \n3Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China  \n4Shanghai Clinical Research Center for Radiation Oncology, Shanghai, China  \n5Shanghai Key Laboratory of Radiation Oncology, Shanghai  \n200032, China  \n© The Author(s) 2025. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will ","cbCaiilZpIGhubRq","https://ap.wps.com/l/cbCaiilZpIGhubRq","pdf",4426769,12,"English","# Abstract\n# Background\n# Methods\n# Results\n# Conclusions\n# Keywords","[{\"question\":\"What problem does the study address in DIBH breast radiotherapy VMAT plans?\",\"answer\":\"Single VMAT delivery times for a breath-hold often exceed the patient’s comfortable DIBH capacity (~20 s), and time delays can reduce real-time tracking accuracy during SGRT.\"},{\"question\":\"How many patients and VMAT plan combinations were evaluated?\",\"answer\":\"The study included 32 left-sided breast cancer patients and generated 16 distinct VMAT plans per patient to compare optimization algorithms (FMO/SPO), fluence modes (FF/FFF), and dose rates.\"},{\"question\":\"What did the bounding factor analysis reveal about delivery limitations?\",\"answer\":\"FMO plans were mainly limited by MLC movement, while SPO plans were mainly limited by MU delivery; applying the strategy affected time and dosimetric quality differently across plan types.\"}]","Shortening breath-hold durations in breast radiotherapy - a novel time-control strategy for deep inspiration breath-hold VMAT | PDF",1790750653,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/bb6053f4c143ca31419430756beede0a.webp",983,1310,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/73a6e4beb21615fc679bc6a4cf4bde5d.webp",982,1309,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/58f3a0e632fab6da10c3735b5c747c3b.webp",981,1308,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1917788065db11895eda13d3bccef136.webp",980,1306]