[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-560886-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-560886-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","service-modes-error-codes-protections-faultfinding-and-repair-tips","Service modes - error codes, protections, faultfinding and repair tips","","Service modes, error codes, protections, and faultfinding guidance for the EM2E chassis. The content explains test points mapped to functional blocks for diagnostics, then details service default mode (SDM) and service alignment mode (SAM), including purposes, parameter specifications, and multiple entry/exit methods. It also introduces Customer Service Mode (CSM) as a read-only customer-activated status mode with defined switching procedures to support troubleshooting.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/service-modes-error-codes-protections-faultfinding-and-repair-tips/560886/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/service-modes-error-codes-protections-faultfinding-and-repair-tips/560886.png","ImageObject",300,407,{"name":42,"@type":43},"Đào","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/msword","2026-11-16","2026-10-12",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What are the EM2E test points used for during diagnostics?","Question",{"text":63,"@type":64},"The EM2E chassis test points are used for diagnostics and are mapped to functional blocks such as power supply, line drive/output circuitry, frame output, rotation, audio, tuner/IF, synchronization, video processing, control/teletext, CRT-panel circuitry, and SCAVEM circuitry.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How is Service Default Mode (SDM) entered and what does it ensure?",{"text":68,"@type":64},"SDM provides predefined settings to obtain the same measurement results as in the manual. It can be entered via RC handset code '062596' with MENU, via ComPair, via the DST 'DEFAULT' button in normal operation, or by short-circuiting specific SDM solder pads; SDM exits only via the STANDBY command.",{"name":70,"@type":61,"acceptedAnswer":71},"What is the purpose and behavior of Customer Service Mode (CSM)?",{"text":72,"@type":64},"CSM helps identify the status of the set during a service technician/dealer telephone conversation. It is a read-only mode, so modifications are not possible; it is switched on by a defined remote MUTE + TV MENU press for at least 4 seconds when no on-screen menu is present.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},560886,1791949952,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":109,"preview_page_count":4},1374402968488,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Service modes, error codes, protections, faultfinding and repair tips EM2E 5. GB 19\n5. Service modes, error codes, protections, faultfinding and repair\ntips\nIn this chapter the following paragraphs are included:\n1. Test points.\n2. Service modes.\n3. Problems and solving tips (related to CSM).\n4. ComPair.\n5. Error codes.\n6. Protections.\n7. Repair tips.\n5.1 Test points\nThe EM2E chassis is equipped with test points in the service\nprinting. These test points are referring to the functional blocks:\n• P1-P2-P3, etc. on LSP: Test points for the power supply.\n• L1-L2-L3, etc. on LSP: Test points for the line drive and\nline output circuitry.\n• F1-F2-F3, etc. on LSP: Test points for the frame output\ncircuitry.\n• R1-R2 on LSP: Test points for the rotation circuitry.\n• A1-A2-A3, etc.: Test points for the audio circuitry.\n• I1-I2-I3, etc. on SSB:Test points for the Tuner/IF part.\n• S1-S2-S3, etc. on SSB: Test points for the synchronisation\ncircuitry.\n• V1-V2-V3, etc. on SSB: Test points for the video\nprocessing circuitry.\n• C1-C2-C3, etc. on SSB: Test points for the control and\nteletext circuitry.\n• F1F-F2F-F3F, etc.: Test points for the CRT-panel circuitry.\n• SC1-SC2-SC3, etc: Test points for the SCAVEM circuitry.\nThe numbering is done in a for diagnostics logical sequence;\nalways start diagnosing within a functional block in the\nsequence of the relevant test points for that functional block.\n5.2 Service modes and ComPair\n5.2.1 Service Default Mode (SDM)\nThe purpose of the SDM is to provide a situation with\npredefined settings to get the same measurement results as\ngiven in this manual.\nSpecification of the SDM:\n• Tuning frequency 475.25 MHz.\n• TV-system for BGLM sets set to BG.\n• All picture settings at 50 % (brightness, colour, contrast,\nhue).\n• All sound settings at 50 % except volume at 25 % (so bass,\ntreble, balance at 50 %, volume at 25 %).\n• All service-unfriendly modes are disabled (like sleep timer,\nchild lock, blue mute, AVL and SDLP).\nEntering the SDM can be done in 4 ways:\n• Via a standard RC-handset by entering the code '062596'\nfollowed by the 'MENU' button (it is possible that, together\nwith the SDM, the main menu will appear. To switch it off,\npush the 'MENU' button again).\n• Via ComPair.\n• By the 'DEFAULT' button on the DST while the set is in the\nnormal operation mode.\n• By short-circuiting for a moment the two solder-pads with\nthe indication 'SDM' (item 4006) on the A-side of the SSB\n(activation can be performed in all modes except when the\nset has a problem with the main-processor).\nNote: If the SDM is entered via the pins, all the softwarecontrolled\nprotections are de-activated.\nExiting the SDM can only be done via the STANDBY\ncommand. By switching off-on the set with the mains switch the\nset will come up again in the SDM.\n5.2.2 Service Alignment Mode (SAM)\nThe purpose of the SAM is to align the set and/or adjust the\nsettings.\nSpecification of the SAM:\n• Software alignments (see chapter 8).\n• Option settings (see chapter 8).\n• Error buffer reading and erasing. The most recent error\ncode is displayed on the left side.\n• Operation counter.\n• Software version.\nEntering the SAM can be done in 4 ways:\n• Via a standard RC-handset by entering the code '062596'\nfollowed by the 'OSD' button [i +] (it is possible that, due to\nthe button sequence, the channel will change to channel 9.\nTo return to the channel of your selection, push the\nappropriate button on the RC).\n• Via ComPair.\n• By the 'ALIGN' button on the DST while the set is in the\nnormal operation mode (or SDM). Enter the password\n'3140' and press OK.\n• By short-circuiting for a moment the two solder-pads with\nthe indication 'SAM' (item 4005) on the A-side of the SSB\n(activation can be performed in all modes except when the\nset has a problem with the main-processor).\nNote: If the SAM is entered via the pins, all the software\ncontrolled protections are de-activated.\nThe Service Alignment Mode menu will now appear on the\nscreen. The following information is displayed:\n• Da","cbCailqmMyyb0zYS","https://ap.wps.com/l/cbCailqmMyyb0zYS","doc",137216,16,"English","# Test points\n# Service modes and ComPair\n## Service Default Mode (SDM)\n## Service Alignment Mode (SAM)\n## Customer Service Mode (CSM)","[{\"question\":\"What are the EM2E test points used for during diagnostics?\",\"answer\":\"The EM2E chassis test points are used for diagnostics and are mapped to functional blocks such as power supply, line drive/output circuitry, frame output, rotation, audio, tuner/IF, synchronization, video processing, control/teletext, CRT-panel circuitry, and SCAVEM circuitry.\"},{\"question\":\"How is Service Default Mode (SDM) entered and what does it ensure?\",\"answer\":\"SDM provides predefined settings to obtain the same measurement results as in the manual. It can be entered via RC handset code '062596' with MENU, via ComPair, via the DST 'DEFAULT' button in normal operation, or by short-circuiting specific SDM solder pads; SDM exits only via the STANDBY command.\"},{\"question\":\"What is the purpose and behavior of Customer Service Mode (CSM)?\",\"answer\":\"CSM helps identify the status of the set during a service technician/dealer telephone conversation. It is a read-only mode, so modifications are not possible; it is switched on by a defined remote MUTE + TV MENU press for at least 4 seconds when no on-screen menu is present.\"}]","Service modes - error codes, protections, faultfinding and repair tips | DOC",1791804401]