[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-647813-105":59,"doc-detail-647813-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","service-bulletin-revision-transmittal-sheet-model-cl-600-2b16-revision-02","SERVICE BULLETIN REVISION TRANSMITTAL SHEET - Model CL-600-2B16 - Revision 02","","Revision 02 of Service Bulletin No. 605-29-006 updates the CL−600−2B16 Service Bulletin Revision 01 dated Oct 19/2015. It replaces the revision information sheet in its entirety and incorporates changes from Modification Summary 600−6330, Rev. K, and updates per the latest Kit Drawing K604−75209. The revision lists specific paragraph and drawing changes, adds parts, and includes guidance on recommended orientation for improved gauge/valve reading and servicing.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/service-bulletin-revision-transmittal-sheet-model-cl-600-2b16-revision-02/647813/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/service-bulletin-revision-transmittal-sheet-model-cl-600-2b16-revision-02/647813.png","ImageObject",300,407,{"name":92,"@type":93},"bocahgabuttt","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-25","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does Revision 02 replace compared with earlier versions?","Question",{"text":112,"@type":113},"Revision 02 discards Revision 01 of the Service Bulletin and the associated information sheet, replacing them in full.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Is any action required if the aircraft already had the Basic Issue or Revision 01 incorporated?",{"text":117,"@type":113},"If the Basic Issue or Revision 01 was already done, this revision has no effect and no other action is necessary. The log book should not be signed if the revision was not performed; keep the previous entry and you may record it as “Not Applicable.”",{"name":119,"@type":110,"acceptedAnswer":120},"What key changes are introduced in Revision 02?",{"text":121,"@type":113},"Revision 02 updates multiple sections and kit/drawing references, adds parts, revises a note for recommended gauge/valve orientation, and includes minor changes without altering overall context.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},647813,1792922653,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":26,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},962094248839,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","SERVICE BULLETIN REVISION TRANSMITTAL SHEET  \nMODEL CL−600−2B16  \nDiscard the Revision 01 of this Service Bulletin dated Oct 19/2015 and the Information Sheet dated Nov 11/2015, and replace in its entirety with this Revision 02.  \nService Bulletin No.  605−29−006   \nDate of Basic Issue  Apr 30/2015   \nRevision No.  \nRevision No.  \n01  \n02  \nDated  \nDated  \n Oct 19/2015   Apr 19/2016   \nThis Revision has no effect for aircraft on which the Basic Issue or Revision 01 of this Service Bulletin was done thus no other action is necessary. Do not sign the log book if you have not done this revision. Keep the previous log book entry. You may make  \nan entry as “Not Applicable” for this revision.  \nThis revision is issued to incorporate the changes given in Modification Summary 600−6330, Rev. K and to update the Service Bulletin per the latest Kit Drawing K604−75209 . The changes are as follows:  \n1. Change Paragraph 1. E. , to update the approval statement as per the latest Service Bulletin template.  \n2. Change, in Paragraph 1. F. , to add clarification to the free cost condition.  \n3. Change, in Paragraph 1. K. , the revision of Modification Summary 600−6330 to Rev. K and the Kit Drawing K604−75209 to Rev. F.  \n4. Revise, Paragraph 2. B.4. (g), to add a Note for the recommended orientation of the pressure gauge/valve for easier reading/servicing access.  \n5. Revise Paragraph 3.A. , to add parts.  \n6. Revise, the Kit Drawing K604−75209 to Rev. F.  \n7. Make miscellaneous minor changes, as necessary, with no change of context.  \n605−29−006  \nSERVICE BULLETIN SUMMARY  \nThis Service Bulletin is available at:  \n[www.cic.bombardier.com](www.cic.bombardier.com)  \nMODEL CL−600−2B16  \nATA 29−12  \nHYDRAULIC POWER  \nMODIFICATION-HYDRAULIC SYSTEM NO. 3-RELOCATION OF THE HYDRAULIC  \nSYSTEM NO. 3 ACCUMULATOR  \nThe information below is provided for your reference. For full details, including labor and part coverage, please see corresponding paragraph contained within this bulletin.  \n\n| RECOMMENDED\u003Cbr>SPECIFIED TIME COMPLIANCE | COMPLIANCE TIME\u003Cbr>See Paragraph 1. D. |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| EFFECTIVITY: AC Serial No. 5701 to 5982 |  |  |  |  |  |  |\n| MANPOWER: 126 man−hours are necessary to do the modification. |  |  |  |  |  |  |\n| CONTINUED AIRWORTHINESS (CAW) FLEET CAMPAIGN |  |  |  |  | |  |\n|  |  | YES | | NO |  |  |\n|  |  |  |  |  |  |  |\n| TLMC, CH 5 AFFECTED | \u003Cbr>YES |  |  |  |  |  |\n|  |  |  | | NO | |  |\n| KITS and/or PARTS | \u003Cbr>YES |  | | NO | |  |\n| TOOLING/GSE | \u003Cbr>YES |  | | NO | |  |\n| PLANNING INFORMATION: See important information at the start of Paragraph 1. | \u003Cbr>YES |  | | NO | |  |\n|  |  |  |  |  |  |  |\n| DEDICATED SCHEDULE | \u003Cbr>YES |  |  |  |  |  |\n|  |  |  | | NO | |  |\n| PREREQUISITE SERVICE BULLETINS: N/A |  |  |  |  |  |  |\n\nTo place an order for parts or kits, please call Bombardier Aerospace Parts Services  \nat:  \n514−855−2999 or 1−866−538−1247  \nBasic Issue: Apr 30/2015 605−29−006  \n Revision 02: Apr 19/2016 Page 1 of 1  \nSERVICE BULLETIN  \nThis Service Bulletin is available at:  \n[www.cic.bombardier.com](www.cic.bombardier.com)  \nMODEL CL−600−2B16  \nATA 29−12  \nHYDRAULIC POWER  \nMODIFICATION-HYDRAULIC SYSTEM NO. 3-RELOCATION OF THE HYDRAULIC  \nSYSTEM NO. 3 ACCUMULATOR  \n1. PLANNING INFORMATION  \nNOTES: 1 . This Service Bulletin is covered by a dedicated schedule. Dedicated schedules are used to reserve and manage inventory due to limited availability of rotable stock, parts and/or kits. Parts are limited, therefore, advance part scheduling with our In−Service Implementation Team (ISIT) is recommended prior to a maintenance visit. Please contact your Regional Manager (RM), Field Service Representative (FSR) or Customer Service Representative (CSR) to schedule your aircraft as there is a limited availability. The parts will be allocated on a first come first serve basis.  \nFor more information on dedicated schedules, refer to SB 605−00−002.  \n2. To minimize aircraft downtime a","cbCaioVjLTnpyiPA","https://ap.wps.com/l/cbCaioVjLTnpyiPA","pdf",2076283,"English","# Revision Overview\n# Compliance and Effectivity\n## Effectivity, Manpower, and CAW Fleet Campaign\n# Planning Information\n## Dedicated Schedule and Part Allocation\n## Downtime and Inspection Timing\n# Aircraft Incorporation Criteria\n## Basic Issue and SNIEO S10\n## Revision 01 and SNIEO S11","[{\"question\":\"What does Revision 02 replace compared with earlier versions?\",\"answer\":\"Revision 02 discards Revision 01 of the Service Bulletin and the associated information sheet, replacing them in full.\"},{\"question\":\"Is any action required if the aircraft already had the Basic Issue or Revision 01 incorporated?\",\"answer\":\"If the Basic Issue or Revision 01 was already done, this revision has no effect and no other action is necessary. The log book should not be signed if the revision was not performed; keep the previous entry and you may record it as “Not Applicable.”\"},{\"question\":\"What key changes are introduced in Revision 02?\",\"answer\":\"Revision 02 updates multiple sections and kit/drawing references, adds parts, revises a note for recommended gauge/valve orientation, and includes minor changes without altering overall context.\"}]","SERVICE BULLETIN REVISION TRANSMITTAL SHEET - Model CL-600-2B16 - Revision 02 | PDF",1792790295,151]