[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646956-105":59,"doc-detail-646956-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","series-8he-gas-fired-boiler-models-807he-808he-809he-810he-installation-operating-and-service-instructions","SERIES 8HE GAS-FIRED BOILER - Models 807HE, 808HE, 809HE & 810HE - Installation, Operating and Service Instructions","","Installation, operating, and service instructions for Series 8HE gas-fired boilers covering models 807HE, 808HE, 809HE, and 810HE. The manual emphasizes installation only by qualified installers, service agencies, or gas suppliers, and warns that improper installation, adjustment, alteration, service, or maintenance can cause property damage, severe injury, death, and/or loss of life. It provides requirements for proper venting, adequate combustion and ventilation air, regular maintenance, and safe handling of pressurized, very hot water. It also lists key USA and Canadian standards and wiring code compliance.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/series-8he-gas-fired-boiler-models-807he-808he-809he-810he-installation-operating-and-service-instructions/646956/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/series-8he-gas-fired-boiler-models-807he-808he-809he-810he-installation-operating-and-service-instructions/646956.png","ImageObject",300,407,{"name":92,"@type":93},"Asher","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-05","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to install, service, or repair the Series 8HE gas-fired boiler?","Question",{"text":112,"@type":113},"The manual states it must only be installed, serviced, or repaired by a qualified installer, service agency, or gas supplier.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What should be done if the user smells gas or fuel oil vapors?",{"text":117,"@type":113},"Do not try to operate the burner/boiler system, do not touch electrical switches or use a phone in the building, and immediately call the gas or oil supplier from a remotely located phone.",{"name":119,"@type":110,"acceptedAnswer":120},"What safety steps are required before disconnecting components?",{"text":121,"@type":113},"Do not unscrew fittings or attempt to disconnect any components unless you positively assure the water is cool and has no pressure, and wear protective clothing and equipment to prevent scald injuries.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646956,1792876250,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":66,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":4},687197207639,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","| INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR |  |  |\n| --- | --- | --- |\n| SERIES 8HE GAS-FIRED BOILER |  |  |\n| Models: 807HE, 808HE, 809HE & 810HE |  |  |\n| |  | |\n| Read these instructions carefully before installing. This boiler must only be installed,serviced, or repaired by qualified installer, service agency or gas supplier. Improper installation, adjustment, aleration, service or maintenance can cause serve personal injury, death, or substantial property damage. For assistance or additional information, consult a qualifed installerm service agency or gas supplier. |  |  |\n| |  |  |\n| Attention Installer-Affix these instructions adjacent to boiler. Provide model number and serial number when  seeking information and support.  Attention Building Owner-Retain these instructions for future reference. Contact a qualified installer, service agency or gas supplier for all issues and support. |  |  |\n|  | | Price- $5.00 |\n|  | Commercial Boilers |  |\n|  | www.burnhamcommercial.com |  |\n\n112407-02-08/24 1  \nIMPORTANT INFORMATION  \nREAD AND SAVE THESE INSTRUCTIONS FOR REFERENCE  \nAll boilers must be installed in accordance with National, State and Local Plumbing, Heating and Electrical Codes and the regulations of the serving utilities. These Codes and Regulations may differ from this instruction manual. Authorities having jurisdiction should be consulted before installations are made.  \nIn all cases, reference should be made to the following Standards:  \nUSA BOILERS  \nA. Current Edition ofAmerican National Standard ANSI/NFPA 31,“Installation of Oil Burning Equipment”, for recommended installation practices.  \nB. Current Edition of National Fuel Gas Code, NFPA 54/ANSI Z223.1.  \nC. Current Edition ofAmerican National Standard ANSI/NFPA 211,“Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances”, For Venting requirements.  \nD. Current Edition ofAmerican Society of Mechanical Engineers ASME CSD-1,“Controls and Safety Devices for Automatically Fired Boilers”, for assembly and operations of controlsand safety devices.  \nE. All wiring on boilers installed in the USA shall be made in accordance with the National Electrical Code and/or Local Regulations.  \nCANADIAN BOILERS  \nA. Current Edition of Canadian Standards Association CSA B139,“Installation Code for Oil Burning Equipment\", for recommended Installation Practices.  \nB. The equipment shall be installed in accordance with the current Installation Code for Gas Burning Appliances and Equipment, CSA B149, and applicable Provincial Regulations for the class; which should be carefully followed in all cases.  \nAuthorities having jurisdiction should be consulted before installations are made.  \nC. All wiring on boilers installed in Canada shall be made in accordance with the Canadian Electrical Code and/or Local Regulations.  \nHazard Definitions  \nThe following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.  \n2 112407-02-08/24  \nDO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.  \nIf you smell gas or fuel oil vapors, do not try to operate the burner/boiler system. Do not touch any electrical switch or use any phone in the building. Immediately call the gas or oil supplier from a remotely located phone.  \nBurner/boiler systems producesteam or hot water in a pressurized vessel by mixing extremely flammable gaseous, liquid or solid fuels with air to produce combustion and very hot products of combustion. Explosions, fires severe personal injury, death and/or property damage will result from improper, careless or inadequate installation, operation or maintenance of fuel-burning and boiler equipment.  \nThis boiler requires regular maintenance and service to operate safely. Follow the instructions contained in this manual.  \n\n| Improper installation, adjustment, alteration, service or","cbCaij4SEvR6Xlwe","https://ap.wps.com/l/cbCaij4SEvR6Xlwe","pdf",4771662,76,"English","[{\"question\":\"Who is allowed to install, service, or repair the Series 8HE gas-fired boiler?\",\"answer\":\"The manual states it must only be installed, serviced, or repaired by a qualified installer, service agency, or gas supplier.\"},{\"question\":\"What should be done if the user smells gas or fuel oil vapors?\",\"answer\":\"Do not try to operate the burner/boiler system, do not touch electrical switches or use a phone in the building, and immediately call the gas or oil supplier from a remotely located phone.\"},{\"question\":\"What safety steps are required before disconnecting components?\",\"answer\":\"Do not unscrew fittings or attempt to disconnect any components unless you positively assure the water is cool and has no pressure, and wear protective clothing and equipment to prevent scald injuries.\"}]","SERIES 8HE GAS-FIRED BOILER - Models 807HE, 808HE, 809HE & 810HE - Installation, Operating and Service Instructions | PDF",1792778570,192]