[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-389958-105":59,"doc-detail-389958-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","series-65a-smoke-heat-detectors-installation-instructions-installation-technical-data","Series 65A Smoke & Heat Detectors Installation Instructions - Installation - Technical Data","","Series 65A smoke and heat detectors installation instructions for multiple mounting bases (4-inch, 6-inch, low profile, and 6-inch E-Z Fit). The document details installation requirements in line with NFPA standards, local codes, and jurisdictional authorities, and emphasizes proper wiring checks for continuity, polarity, and insulation resistance. It provides mounting and sealing guidance, terminal connection notes, CAUTION wiring supervision instructions, and wiring diagram references. It concludes with detector technical data including model compatibility, detector type options, electrical ratings, currents, test methods, and operating temperature limits.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/series-65a-smoke-heat-detectors-installation-instructions-installation-technical-data/389958/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/series-65a-smoke-heat-detectors-installation-instructions-installation-technical-data/389958.png","ImageObject",300,407,{"name":92,"@type":93},"Bintang","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-06","2026-09-25",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What standards and requirements must be followed during installation?","Question",{"text":113,"@type":114},"The products must be installed according to applicable NFPA standards, local codes, and jurisdictional authorities. Failure to follow the instructions may cause detectors to fail to report an alarm condition.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What wiring checks should be performed before installing the detectors?",{"text":118,"@type":114},"Before installing, check continuity, polarity, and insulation resistance of all wiring. Also confirm the location matches the fire system drawings and conforms to local codes such as NFPA 72.",{"name":120,"@type":111,"acceptedAnswer":121},"What CAUTION applies to wiring under terminal L2?",{"text":122,"@type":114},"Do not use looped wire under terminal L2. Break the wire run to provide supervision of connections.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},389958,1790478420,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":24,"preview_page_count":4},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","39214-118/Rev 6A  \nSeries 65A Smoke & Heat Detectors Installation Instructions  \nGeneral  \nThese instructions apply to the 4\" mounting base, part no 45681-200, the 6\" mounting base, part no 45681-220, the low proﬁ le base, part no 45681-232 and the 6\" E-Z Fit base, part no 45681-251, for installing Series 65A smoke and heat detectors.  \nInstallation  \nThese products must be installed in accordance with the applicable NFPA standards, local codes and jurisdictional authorities. Failure to follow these instructions may result in failure of the detectors to report an alarm condition. Apollo Fire Detector Limited is not responsible for detectors which are improperly installed, maintained and tested.  \nBefore installing these products check the continuity, polarity and insulation resistance of all wiring. Check that siting is in accordance with the ﬁre system drawings and conforms to all applicable local codes such as NFPA 72.  \nUse 3\" octagonal box for direct connection to the base. 4\" octagonal and 4\" square boxes may be used with proper UL listed mounting brackets. When mounting on a wall, install 4\" to 12\" from the ceiling. Use 3M Weatherban 606 Non-Flammable sealing compound (or equivalent) to seal ﬁeld wiring conduit opening in the electrical box, this will reduce the stacking effect. Secure the base to the electrical box with appropriate screws. Do not overtighten the screws. The raised mark on the side of the base indicates the direction of the detector LED when ﬁtted. Connect the shield, if required, to the SHIELD terminal on the base.  \n©Apollo Fire Detectors Ltd 1994–2011  \nApollo Fire Detectors Ltd, 36 Brookside Road, Havant, Hants, PO9 1JR, UK  \nTel +44 (0)23 9249 2412 Fax +44 (0)23 9249 2754  \nEmail: techsales@apollo-ﬁ[re.co.uk Website: www.apollo-](re.co.uk Website: www.apollo-)ﬁ[re.co.uk](re.co.uk)  \nIn the USA: Apollo America, 821 Ulrich Ave, Louisville, KY 40219, USA  \nTel: (502) 964-6565 Fax: (502) 964-6229  \nEmail: infoUSA@apollo-ﬁ[re.com](re.com) Website: www.apollo-ﬁre.com  \nWiring  \nCAUTION: Do not use looped wire under terminal L2. Break wire run to provide supervision of connections.  \nFig 1 Wiring diagram of Series 65A zone  \nFig 2 Wiring diagram of Series 65A zone with common remote indicator  \n.  \nThe above instructions cover the following base model:  \n45681-200  \n45681-220  \n45681-232  \n45681-251  \n4\" mounting base 6\" mounting base low proﬁ le base 6\" E-Z Fit base  \nTechnical Data  \n\n| Detector Model No | 55000-138, 139, 140, 141, 142, 143, 144, 145, 146 |  | 55000-225, 226, 227 | 55000-325, 326, 327, 328 |\n| --- | --- | --- | --- | --- |\n| Detector Type | Heat Rate-of-Rise/Fixed Temperature |  | Ionization | Photoelectric |\n| Working Voltage | 9–33V DC |  | 9–33V DC | 9–33V DC |\n| Maximum Alarm Current | 17mA at 9V, 52mA at 24V |  | 17mA at 9V, 52mAat 24V | 17mA at 9V, 52mAat 24V |\n| Surge Current | 0mA |  | 0mA | 0mA |\n| Supervisory Current | 40–50 μA at 9V, 45–55 μA at 24V |  | 40–50 μA at 9V, 45–55 μA at 24V | 40–50 μA at 9V, 45–55 μA at 24V |\n| Heat Element Rating | 55000-138, 139, 140 | Ordinary (135ºF/57ºC) | N/A | N/A |\n|  | 55000-141, 142, 143 | Ordinary (170ºF/77ºC) |  |  |\n|  | 55000-144, 145, 146 | Intermediate\u003Cbr>(200ºF/93ºC) |  |  |\n| Compatibility Identiﬁer | 55000-138, 139, 140, 141, 142, 143, 144, 145, 146 |  | 55000-225, 226, 227 | 55000-325, 326, 327, 328 |\n| Test Method | Magnet or hair dryer |  | Magnet or Gemini 501 | Magnet or Gemini 501 |\n| Installation Temperature | Minimum 32ºF (0ºC)\u003Cbr>Maximum at least 20ºF (11ºC) below rating |  | Minimum 32ºF (0ºC)\u003Cbr>Maximum 158ºF (70ºC) | Minimum 32ºF (0ºC)\u003Cbr>Maximum 140ºF (60ºC) |\n| Control Panel | Refer to www. apollo-ﬁ[re.co.uk for compatible panels](re.co.uk for compatible panels) |  |  |  |","cbCaiqiuZrOOgXZz","https://ap.wps.com/l/cbCaiqiuZrOOgXZz","pdf",86295,"English","# Installation\n## Wiring\n## Technical Data","[{\"question\":\"What standards and requirements must be followed during installation?\",\"answer\":\"The products must be installed according to applicable NFPA standards, local codes, and jurisdictional authorities. Failure to follow the instructions may cause detectors to fail to report an alarm condition.\"},{\"question\":\"What wiring checks should be performed before installing the detectors?\",\"answer\":\"Before installing, check continuity, polarity, and insulation resistance of all wiring. Also confirm the location matches the fire system drawings and conforms to local codes such as NFPA 72.\"},{\"question\":\"What CAUTION applies to wiring under terminal L2?\",\"answer\":\"Do not use looped wire under terminal L2. Break the wire run to provide supervision of connections.\"}]","Series 65A Smoke & Heat Detectors Installation Instructions - Installation - Technical Data | PDF",1790328727]