[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-676957-105":59,"doc-detail-676957-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","sentinel-1-125-control-valve-with-fully-adjustable-cycles-operation-and-instruction-manual-for-oemdealer","Sentinel - 1\" & 1.25\" Control Valve with Fully Adjustable Cycles - Operation and Instruction Manual for OEM/Dealer","","This manual provides operation and instruction guidance for the Sentinel™ water softener control valve (1\" and 1.25\") used with OEM and dealer systems. It explains the valve’s purpose for water softeners or filters, clarifies that OEM system manuals must include required warnings and specifications, and provides safe handling and maintenance practices. Detailed reset procedures for the electronics, plumbing code guidance, drain line sizing, soldering precautions, fitting assembly steps, and electrical grounding requirements are included. Specification tables cover operating pressure and temperature ranges, AC adapter parameters, and quick reference performance data for service and backwash flow rates, plus fitting options and key dimensions.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/sentinel-1-125-control-valve-with-fully-adjustable-cycles-operation-and-instruction-manual-for-oemdealer/676957/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/sentinel-1-125-control-valve-with-fully-adjustable-cycles-operation-and-instruction-manual-for-oemdealer/676957.png","ImageObject",300,407,{"name":92,"@type":93},"Aurelia","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is the purpose of this manual for Sentinel water softeners?","Question",{"text":111,"@type":112},"The manual supports water treatment equipment manufacturers in selecting control valve options for softeners or filters. It is not intended to replace a complete installation or servicing manual for a specific water treatment system.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What lubricants should not be used during maintenance?",{"text":116,"@type":112},"Avoid Vaseline, oils, other hydrocarbon lubricants, and spray silicone anywhere. Silicone lubricant may be used on black o-rings, but it is not necessary, and lubricants including silicone should be avoided on clear lip seals.",{"name":118,"@type":109,"acceptedAnswer":119},"How do you reset the valve electronics after drive assembly or piston maintenance?",{"text":120,"@type":112},"Press and hold the NEXT and REGEN buttons for 3 seconds, or unplug the power source jack from the printed circuit board (black wire) and plug it back in. The display should flash all wording, then flash the software version, and reset the valve to the service position.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},676957,1793777176,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},1099514068365,"https://ap-avatar.wpscdn.com/avatar/10000253d8d9f28188e?_k=1776742907772140068","Sentinel™ Water Softeners  \n1” & 1.25” Control Valve with Fully Adjustable Cycles  \nOperation and Instruction Manual for OEM/Dealer  \nIntroduction  \nThis manual is about a control valve to be used on water softeners or water filters. The manual is designed to aid water treatment equipment manufacturers in the selection of the various control valve options. Information in this manual is different than what is needed for installation and servicing of a particular water treatment system. This manual is not intended to be used as a manual fora complete water softener or filter. Certain parts of the manual will serve as aids to manufacturers in the writing and layout of the manuals for installers and service personnel.  \nThe following general warnings and the specifications in Table 1 must appear in the OEM’s System Manual.  \nThe control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments but are not designed to support the weight of a system or the plumbing.  \nDo not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicone lubricant may be used on black o-rings but is not necessary. Avoid any type of lubricants, including silicone, on the clear lip seals.  \nThe nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench. If necessary a pliers can be used to unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place a screwdriver in the slots on caps and/or tap with a hammer.  \nDo not use pipe dope or other sealants on threads. Use Teflon tape on the threaded inlet, outlet and drain fittings. Teflon tape is not necessary on the nut connection or caps because of o-ring seals.  \nAfter completing any valve maintenance involving the drive assembly or the drive cap assembly and pistons, press and hold NEXT and REGEN buttons for 3 seconds or unplug power source jack from the printed circuit board (black wire) and plug back in. This resets the electronics and establishes the service piston position. The display should flash all wording, then flash the software version and then reset the valve to the service position.  \nAll plumbing should be done in accordance with local plumbing codes. The pipe size for the drain line should be a minimum of ½”. Backwash flow rates in excess of 7 gpm or length in excess of 20’ require ¾” drain line.  \nSolder joints near the drain must be done prior to connecting the drain line flow control fitting. Leave at least 6” between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting. Failure to do this could cause interior damage to the drain line flow control fitting.  \nWhen assembling the installation fitting package (inlet and outlet), connect the fitting to the plumbing system first and then attach the nut, split ring and o-ring. Heat from soldering or solvent cements may damage the nut, split ring or o-ring. Solder joints should be cool and solvent cements should be set before installing the nut, split ring and o-ring. Avoid getting primer and solvent cement on any part of the o-rings, split rings, bypass valve or control valve.  \nPlug into an electrical outlet. Note: All electrical connections must be connected according to local codes. (Be certain the outlet is uninterrupted.)  \nInstall grounding strap on metal pipes.  \nTable 1  \nSpecifications which must be included in OEM’s Manual  \n\n| Minimum/Maximum Operating Pressures | 20 psi (138 kPa) -125 psi (862 kPa) |\n| --- | --- |\n| Minimum/Maximum Operating Temperatures | 40°F (4°C) -110°F (43°C) |\n| AC Adapter:\u003Cbr>Supply Voltage\u003Cbr>Supply Frequency\u003Cbr>Output Voltage\u003Cbr>Output Current | U. S.  International\u003Cbr>120 VAC 230 VAC\u003Cbr>60 Hz 50 Hz\u003Cbr>12 VAC 12 VAC\u003Cbr>500 mA 500 mA |\n| No user serviceable parts are on the PC board, the motor, or the AC adapter. The means of disconnection from the main power supply is by unplugging the AC adapter from the wal","cbCaiqR9Hgb0GWKT","https://ap.wps.com/l/cbCaiqR9Hgb0GWKT","pdf",1338374,32,"English","# Introduction\n## General warnings and installation/service cautions\n## Reset and electronics service procedure\n## Plumbing and electrical requirements\n## Table 1 - Required specifications for OEM system manual\n## Table 2 - Quick reference specifications\n## Control valve and bypass valve options and dimensions","[{\"question\":\"What is the purpose of this manual for Sentinel water softeners?\",\"answer\":\"The manual supports water treatment equipment manufacturers in selecting control valve options for softeners or filters. It is not intended to replace a complete installation or servicing manual for a specific water treatment system.\"},{\"question\":\"What lubricants should not be used during maintenance?\",\"answer\":\"Avoid Vaseline, oils, other hydrocarbon lubricants, and spray silicone anywhere. Silicone lubricant may be used on black o-rings, but it is not necessary, and lubricants including silicone should be avoided on clear lip seals.\"},{\"question\":\"How do you reset the valve electronics after drive assembly or piston maintenance?\",\"answer\":\"Press and hold the NEXT and REGEN buttons for 3 seconds, or unplug the power source jack from the printed circuit board (black wire) and plug it back in. The display should flash all wording, then flash the software version, and reset the valve to the service position.\"}]","Sentinel - 1\" & 1.25\" Control Valve with Fully Adjustable Cycles - Operation and Instruction Manual for OEM/Dealer | PDF",81]