[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-676708-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-676708-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","sensotec-model-gm-signal-conditioner-indicator-008-0186-00-product-manual","SENSOTEC Model GM Signal Conditioner-Indicator - 008-0186-00 - Product Manual","","SENSOTEC Model GM Signal Conditioner-Indicator provides a complete 4V/2-digit signal conditioning and display system in a 1/8 DIN case. It supports 0.5 to 50 mV/V strain-gage transducer inputs, provides 0–5V output, and features +/-0.03% accuracy with engineering-unit display and 20,000-count resolution. The manual covers configuration with multiple circuit boards, excitation voltage selection (5 or 10 VDC), mounting options, unpacking guidance, and front-panel adjustments including coarse/fine span and zero, plus available optional functions.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/sensotec-model-gm-signal-conditioner-indicator-008-0186-00-product-manual/676708/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/sensotec-model-gm-signal-conditioner-indicator-008-0186-00-product-manual/676708.png","ImageObject",300,407,{"name":42,"@type":43},"ahduag","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":51,"interactionType":52,"userInteractionCount":4},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What signal inputs and excitation voltage does the SENSOTEC Model GM support?","Question",{"text":61,"@type":62},"It accepts strain-gage transducer inputs in the range of 0.5 to 50 mV/V and provides selectable 5- or 10-volt excitation. The manual also references checking or changing the factory excitation setting.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"How are span and zero adjustments performed on the unit?",{"text":66,"@type":62},"The manual provides adjustments for coarse span, fine span, coarse zero, fine zero, and scaling. Fine zero and fine span can be adjusted from the front panel without removing the front bezel.",{"name":68,"@type":59,"acceptedAnswer":69},"What options are available for the Model GM, and are they installable together?",{"text":70,"@type":62},"Optional Dual Limits, Peak Detector, and Track-and-Hold are supported. Due to space constraints, only one option can be installed on a particular unit.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},676708,1793776496,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":116,"language":138,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":12,"update_tm":78,"read_time":101},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","SENSOTEC  \n008-0186-00  \n# TABLE OF CONTENTS\n\nSubject  \nPage  \n1.0 Introduction………………………………………………………………………………………………………………2  \n2.0 Description…………………………………………………………………………………………………………………2  \n2.1 Configuration ……………………………………………………………………………………………………………2  \n2.2 Specifications……………………………………………………………………………………………………3  \n3.0 Unpacking, Installation and Wiring……………………………………………………………4  \n3.1 Selecting Excitation Voltage …………………………………………………………………………4  \n3.5 Wiring to the Optional Limits…………………………………………………………………………5  \n4.2.1 Span Adjustment, with Shunt Calibration …………………………………………………7  \n5.0 Operative Adjustments…………………………………………………………………………………10  \n5.2 Fine Span Adjustments…………………………………………………………………………………10  \n6.0 Changing the Shunt Calibration Resistor………………………………………………10  \n7.0 Options………………………………………………………………………………………………………12  \n7.1 High/Low Limits Option ……………………………………………………………………………………12  \n7.1.1 Setting the Limits Adjustments………………………………………………………………………12  \n7.2 Peak Detector Option …………………………………………………………………………………………13  \n7.3 Track-and-Hold Option ………………………………………………………………………………………14  \n8.0 Troubleshooting Guide…………………………………………………………………………………14  \n9.0 Drawings ……………………………………………………………………………………………………15  \n10.0 Warranty/Repair Policy……………………………………………………………………………15  \n10.1 Limited Warranty on Products …………………………………………………………………………15  \n10.2 Obtaining Service Under Warranty……………………………………………………………15  \n10.4 Repair Warranty ……………………………………………………………………………………………16  \n11.0 Glossary of Signal Conditioning Terms …………………………………………………16  \n# SENSOTEC MODEL GMSIGNAL CONDITIONER-INDICATOR\n\n## 1.0 Introduction\n\nThe SENSOTEC Model GM Signal Conditioner-Indicator is a complete4V/2 digit signal conditioner and indicator housed in a 1/8 DIN case.This unit provides many of the features found on expensive,largersignal conditioning units:  \n● Full 4V/2 digit,0.56-inch display  \n·Display in any engineering unit desired  \n·Full 20,000 count resolution  \n·Accepts strain-gage transducer inputs from 0.5 to 50 mv/v  \n·0-5V output  \n·+/-0.03%accuracy  \n·Compression type power and I/0 connectors  \n·Shunt calibration rom front-panel  \n·1/8 DIN\"panel meter size\"case  \n●5-or 10-volt transducer excitation  \n·Optional Dual Limits  \n·Optional Peak Detector  \n·Optional Track-and-Hold  \n·110-or 220-V Power  \n2.0 Description  \n2.1 Configuration.Within the Model GM's enclosure there are threeprinted circuit boards(four if an option is selected).The Main Boardcontains the circuitry for the power supply and A/D converter.TheDisplay Board contains all circuitry needed to drive the LED displayand the units display bar.The Signal Conditioner Board contains cir-cuitry for the signal amplifier and for the excitation power supply.The Display Board solders to the Main Board,whereas the SignalConditioner Board plugs into it.If the Dual Limits,Peak Detector orTrack-and-Hold option is supplied,a fourth plug-in board houses it.DUE TO SPACE CONSTRAINTS,ONLY ONE OPTION CAN BE IN-STALLED ON A PARTICULAR UNIT.Adjustments for COARSE SPAN,FINE SPAN,COARSE ZER0,FINE ZERO,and SCALING are provided.FINE ZER0 and FINE SPAN may be adjusted from the front panelwithout removing the front bezel.The entire unit may be quicklypanel or rack mounted with the snap-on attachments supplied withevery unit.  \n## 2.2 Specifications:\n\nCase Material   ………  \nTRANSDUCERTransducer Excitation..........INTERFACEType of inputs accepted.......  \n5 or 10 VDC  \n0.5 mv/v to 5.0 mv/vor 5 mv/v to 50 mv/v5010-1000YesManual(front panel)+/-15%F.S.Min\u003C100 microvolts350 Ω(10v Exc.)  \nTransducer Current drive(ma.)..nput Gain Range.............Push Button Shunt Cal ........Calibration Method............Transducer Minimum Impedance  \nAMPLIFIERCHARACTERISTICS  \n5 Volts  \nOutput Impedance............  \n\u003C2 ohms  \n+/-0.03%  \nFrequency Response.........  \n>100 Hz.  \nCommon Mode Rejection.......  \n>80 dB.  \n+/-15%  \nCoarse Span Adjust..........  \n>80%  \nFine Zero Adjust..............  \n+/-15%  \nCoarse Zero Adjust............  \n>80%  \nShort Circuit Protected.........  \n","cbCainUJSiQ7DbrB","https://ap.wps.com/l/cbCainUJSiQ7DbrB","pdf",2513760,"English","# TABLE OF CONTENTS\n## 1.0 Introduction\n## 2.0 Description\n## 2.1 Configuration\n## 2.2 Specifications\n## 3.0 Unpacking, Installation and Wiring\n## 3.1 Selecting Excitation Voltage\n## 3.5 Wiring to the Optional Limits\n## 4.2.1 Span Adjustment, with Shunt Calibration\n## 5.0 Operative Adjustments\n## 5.2 Fine Span Adjustments\n## 6.0 Changing the Shunt Calibration Resistor\n## 7.0 Options\n## 7.1 High/Low Limits Option\n## 7.2 Peak Detector Option\n## 7.3 Track-and-Hold Option\n## 8.0 Troubleshooting Guide\n## 9.0 Drawings\n## 10.0 Warranty/Repair Policy\n## 11.0 Glossary of Signal Conditioning Terms","[{\"question\":\"What signal inputs and excitation voltage does the SENSOTEC Model GM support?\",\"answer\":\"It accepts strain-gage transducer inputs in the range of 0.5 to 50 mV/V and provides selectable 5- or 10-volt excitation. The manual also references checking or changing the factory excitation setting.\"},{\"question\":\"How are span and zero adjustments performed on the unit?\",\"answer\":\"The manual provides adjustments for coarse span, fine span, coarse zero, fine zero, and scaling. Fine zero and fine span can be adjusted from the front panel without removing the front bezel.\"},{\"question\":\"What options are available for the Model GM, and are they installable together?\",\"answer\":\"Optional Dual Limits, Peak Detector, and Track-and-Hold are supported. Due to space constraints, only one option can be installed on a particular unit.\"}]","SENSOTEC Model GM Signal Conditioner-Indicator - 008-0186-00 - Product Manual | PDF"]