[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-676713-105":59,"doc-detail-676713-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","sensepoint-xcl-fixed-point-gas-detector-instruction-manual","Sensepoint XCL Fixed Point Gas Detector - Instruction Manual","","Instruction manual for the Sensepoint XCL fixed point gas detector, explaining how to install, operate, and maintain the product. It emphasizes reading the manual fully before installation, highlights Honeywell’s statements on accuracy, error reporting, and revision rights, and includes a revision history by issue and date. The contents outline introduction topics such as features, appearance, detectable gases, detector versions, and specifications, followed by installation, commissioning, maintenance, mobile app, security, and appendices covering parameters, troubleshooting, ordering, warranty, wireless safety, certification, and Modbus registers.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/sensepoint-xcl-fixed-point-gas-detector-instruction-manual/676713/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/sensepoint-xcl-fixed-point-gas-detector-instruction-manual/676713.png","ImageObject",300,407,{"name":92,"@type":93},"asba","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is the purpose of this Sensepoint XCL instruction manual?","Question",{"text":111,"@type":112},"It describes how to install and use the Sensepoint XCL fixed point gas detector and should be read by anyone who installs, operates, or maintains these products.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What communication and output interfaces are supported by Sensepoint XCL?",{"text":116,"@type":112},"Sensepoint XCL supports an analog current loop output (typically 4 to 20 mA), Modbus RTU digital communications, and two change-over relay outputs for external control or alarm devices.",{"name":118,"@type":109,"acceptedAnswer":119},"Which stages are covered after installation in the manual?",{"text":120,"@type":112},"After installation, the manual covers commissioning (including commissioning the detector and target gas selection) and maintenance (including calibration, bump test, sensor replacement, and resetting alarms and faults).","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},676713,1793776507,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},3985747872567,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","INSTRUCTIONMANUAL  \nSensepoint XCL  \nFixed Point Gas Detector  \nAbout This Manual  \nThis manual describes how to installand use the Sensepoint XCLgasdetector and should be read by anyone who installs,operates,ormaintains these products.  \nRead and understand this manual in full before you installthe product.While every effort has been made to ensure the accuracy of thisdocument,Honeywell can assume no responsibility for any errors oromissions ortheirconsequences.Honeywell wouldgreatly appreciatebeing informed of any errors or omissions that may be found in thecontent of this document.For information not covered in thisdocument,or to send comments or corrections,please contactHoneywell using the contact details given on the back page.  \nHoneywell reserves the right to change or revise the informationsupplied in this document without notice and without obligation tonotify any person ororganization of such revision or change.  \nREVISION HISTORY  \n\n| ISSUE   | ECO Number   | DATE   |\n| --- | --- | --- |\n| 4   | HAA190009   | May 2019   |\n| 5   | ECN-00210050   | March 2021   |\n| 6   | ECN-00230030   | May 2023   |\n\nContents  \n2  \nAbout This Manual  \nContents  \n3  \n1 Introduction  \n6  \n1.1 Features…………………………………………………………………………………………………………………………………………………6  \n1.2 Appearance………………………………………………………………………………………………………………7  \n1.3 Accessories………………………………………………………………………………………………………………………………7  \n1.4 Detectable Gases……………………………………………………………………………………………………………8  \n1.5 Detector Versions……………………………………………………………………………………………………………8  \nAnalog(mA)Output Version………………………………………………………………………………8  \nModbus Output Version…………………………………………………………………………………………9  \n1.6 Relay Outpu………………………………………………………………………………………………………………9  \n1.7 Specifications……………………………………………………………………………………………………10  \nDimensions and Weight………………………………………………………………………………………10  \nPowerSupply………………………………………………………………………………………………………10  \nOutput………………………………………………………………………………………………………………………11  \nMaximum Power Consumption…………………………………………………………………11  \nOperating Environmen…………………………………………………………………………………………12  \nRecommended Wall-Mounting Screw………………………………………………………12  \nCable Gland……………………………………………………………………………………………………………………12  \nGas Test Tubing……………………………………………………………………………………………………12  \nGas……………………………………………………………………………………………………………………13  \n14  \n2 Installation  \n2.1 Safety Information………………………………………………………………………………………………14  \n2.2 Installation Layout……………………………………………………………………………………………15  \n2.3 Power Cable Specification……………………………………………………………………………………15  \n2.4 Detector Module…………………………………………………………………………………………………………17  \n2.5 Wiring of mA Output Version……………………………………………………………………17  \nPower Connection………………………………………………………………………………………………………17  \nInhibit Level Selection………………………………………………………………………………………………18  \nCurrent Source/Sink Selection…………………………………………………………………………18  \n2.6 Wiring of Modbus Output Version………………………………………………………20  \nModbus Connection…………………………………………………………………………………………20  \nCable Specification for Modbus Connection……………………………………21  \nTerminal Resistor…………………………………………………………………………………………………………………21  \n2.7 Securing the Back Boxto a Wal………………………………………………………………22  \n2.8 Cable Connections……………………………………………………………………………………………………22  \n2.9 Ground Connection…………………………………………………………………………………………24  \n2.10Securing the Detector Moduleto the Back Bo…………………………………25  \n2.11 Remote Gassing Connection……………………………………………………………………26  \n3 Commissioning  \n28  \n3.1 Commissioning the Detecto…………………………………………………………………………28  \n3.2 Status Indicator………………………………………………………………………………………………………………………30  \n3.3 Target Gas Selection(flammable catalytic versions only………32  \n4 Maintenance  \n33  \n4.1 Using the Control Button………………………………………………………………………………33  \n4.2 Maintenance Status Indicator…………………………………………………………………………34  \n4.3 Calibration Cap……………………………………………………………………………………………………35  \n4.4 Calibration…………………………………………………………………………………………………………………………37  \n4.5 Bump Test………………………………………………………………………………………………………………39  \n4.6 Replacing the Sensor……………………………………………………………………………………40  \n4.7 Resetting Alarms an","cbCaida7zHQAG9Ym","https://ap.wps.com/l/cbCaida7zHQAG9Ym","pdf",9835372,63,"English","# About This Manual\n# 1 Introduction\n## 1.1 Features\n## 1.2 Appearance\n## 1.3 Accessories\n## 1.4 Detectable Gases\n## 1.5 Detector Versions\n## 1.6 Relay Output\n## 1.7 Specifications\n# 2 Installation\n## 2.1 Safety Information\n## 2.2 Installation Layout\n## 2.3 Power Cable Specification\n## 2.4 Detector Module\n## 2.5 Wiring of mA Output Version\n## 2.6 Wiring of Modbus Output Version\n## 2.7 Securing the Back Box to a Wall\n## 2.8 Cable Connections\n## 2.9 Ground Connection\n## 2.10 Securing the Detector Module to the Back Box\n## 2.11 Remote Gassing Connection\n# 3 Commissioning\n## 3.1 Commissioning the Detector\n## 3.2 Status Indicator\n## 3.3 Target Gas Selection\n# 4 Maintenance\n## 4.1 Using the Control Button\n## 4.2 Maintenance Status Indicator\n## 4.3 Calibration Cap\n## 4.4 Calibration\n## 4.5 Bump Test\n## 4.6 Replacing the Sensor\n## 4.7 Resetting Alarms and Faults\n# 5 Mobile App\n# 6 Security Guide\n# Appendix A Detector Parameters\n# Appendix B Troubleshooting\n## B.1 Warning\n## B.2 Fault\n# Appendix C Ordering Information\n## C.1 Detectors\n## C.2 Accessories\n## C.3 Consumables\n## C.4 Spares\n# Appendix D Warranty\n# Appendix E Safety Information for Wireless Devices\n## E.1 FCC Compliance\n## E.2 IC Compliance\n## E.3 RED Compliance\n# Appendix F Certification\n# Appendix G Modbus Registers\n# Appendix H Contact Information","[{\"question\":\"What is the purpose of this Sensepoint XCL instruction manual?\",\"answer\":\"It describes how to install and use the Sensepoint XCL fixed point gas detector and should be read by anyone who installs, operates, or maintains these products.\"},{\"question\":\"What communication and output interfaces are supported by Sensepoint XCL?\",\"answer\":\"Sensepoint XCL supports an analog current loop output (typically 4 to 20 mA), Modbus RTU digital communications, and two change-over relay outputs for external control or alarm devices.\"},{\"question\":\"Which stages are covered after installation in the manual?\",\"answer\":\"After installation, the manual covers commissioning (including commissioning the detector and target gas selection) and maintenance (including calibration, bump test, sensor replacement, and resetting alarms and faults).\"}]","Sensepoint XCL Fixed Point Gas Detector - Instruction Manual | PDF",159]