[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-141200-en":3,"doc-seo-141200-105":30,"detail-sidebar-cat-0-en-105":90},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":4,"category_id":11,"category_name":12,"doc_title":13,"doc_description":14,"doc_content":15,"file_id":16,"file_url":17,"file_type":18,"file_size":19,"view_count":4,"is_deleted":4,"is_public":20,"is_downloadable":20,"audit_status":20,"page_count":21,"language":22,"language_code":23,"site_id":24,"html_lang":23,"table_of_contents":25,"faqs":26,"seo_title":27,"seo_description":14,"update_tm":28,"read_time":29},141200,137451211410,"\tCallum ","https://ap-avatar.wpscdn.com/avatar/2000bb0a9246f588df?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786362646172706240",6,"Technology","SEKI - Snap Action Thermostat Feature & Ratings","SEKI snap action temperature control thermostats provide IEC-compliant safety design with manual or automatic reset options and single-operation fuse disc availability. The contacts are specified for open behavior on temperature rise and no closure until temperatures reach 0°C or below -35°C, with both horizontal and vertical terminal support. Temperature setpoints range from -20°C to 180°C, with tight indicated temperature tolerance and defined on-off differential and cycle life under resistive loads. Models are listed across international approvals including UL, TUV, CQC, and KC.","# ●FEATURE\n\nSnap Action  \n-Safety Design according to IEC Standard  \n-Manual and Automatic Resettable  \n-Single Operation Fuse Disc Available Contacts:Open on temperature rise,no closure unlessthe temperature 0°Cor below-35°C  \n-Horizontal and Vertical Terminal Available  \n-Customized Wire Connection and Bracket TypeAvailable  \n# ●APPLICATION\n\nAutomatic coffeemakers,Water heaters,Sandwich toasters,Dishwashers,Boilers,Dryers,Electric heaters,Washing machines,Refrigerators,Microwave ovens,Water purifiers,Bidet,etc.●TEMPERATURE SETTING RANGE(at no load)-20℃ to 180℃  \n# ● TOLERANCE\n\nIndicated temp.±3℃,±5℃  \n●ON-OFF DIFFERENTIAL TEMP.(general)Min 7~10K  \n●CYCLE LIFE(Resistive Load)  \n15A/125V AC 100,000 cycles  \n7.5A/250V AC 100,000cycles●CONTACT SYSTEMNormally Closed/Normally Open  \n# SEKI\n\nCONTROLS  \nPreventing hazards due to overheating worldwide.  \nSEKI is always by your side.  \nWWW.sekiconscom  \n# ● APPROVAL/RATINGS\n\n\n| Agency   | Standard   | Category   | Electrical Ratings   | Max Temp   | File NO.   |\n| --- | --- | --- | --- | --- | --- |\n| UL  \u003Cbr>(c-ULus)   | UL873  \u003Cbr>C22.2 No.24-93   | Limiting  \u003Cbr>Thermostats   | AC 125V/15A,240V/15A,  \u003Cbr>250V/7.5A 100,000 cycles(HB-2)   | 150℃   | E179705  \u003Cbr>(HB-2,HB-5)   |\n|  |  |  | AC 125V15A,250V/7.5A  \u003Cbr>100,000 cycles(HB-5)   |  |  |\n| TUV   | EN 60730-1  \u003Cbr>EN60730-2-9   | Temperature  \u003Cbr>Controller   | AC 125V/15A,250V/7.5A  \u003Cbr>100,000 cycles   | 150℃   | B170599579006  \u003Cbr>(HB-2,HB-5)   |\n| CQC   | GB/T14536.1-  \u003Cbr>2008  \u003Cbr>GB/T14536.10-  \u003Cbr>2008   | Thermostat   | AC 125V/15A,250V/7.5A  \u003Cbr>10,000 cycles   | 150℃   | CQC17002173860  \u003Cbr>(HB-2)   |\n|  |  |  |  |  | CQC17002173859  \u003Cbr>(HB-5)   |\n| KC   | KC60730-1  \u003Cbr>K60730-2-9   | Thermostat   | AC 250V/7.5A   | 150℃   | ZH02005-15001  \u003Cbr>(HB-2,HB-5)   |\n|  | K60730-2-9   |  | AC 250V/15A   | 180℃   | ZH02005-12001  \u003Cbr>(HB-21P)   |\n\n# ● WARNING\n\nYou may happen to encounter counterfeits of SEKl products in the market,all of which cause a seriousdamage by their serious defectives in quality.Therefore it is strongly recommended that you purchaseauthentic SEKI products from our AUTHORIZED distributors.","cbCainpY7Z6h4J0n","https://ap.wps.com/l/cbCainpY7Z6h4J0n","pdf",2476413,1,2,"English","en",105,"# FEATURE\n## APPLICATION\n## TEMPERATURE SETTING RANGE\n## TOLERANCE\n## ON-OFF DIFFERENTIAL AND CYCLE LIFE\n## CONTACT SYSTEM\n## APPROVAL/RATINGS\n## WARNING","[{\"question\":\"What safety design features do these SEKI snap action thermostats include?\",\"answer\":\"They use IEC-standard safety design, with manual and automatic resettable options and a single-operation fuse disc. The contacts are configured to prevent closure until the specified temperature conditions are met.\"},{\"question\":\"What is the temperature setting range and tolerance?\",\"answer\":\"The temperature setting range (at no load) is -20°C to 180°C. The indicated temperature tolerance is ±3°C and ±5°C, depending on the specification.\"},{\"question\":\"What electrical and endurance ratings are provided?\",\"answer\":\"Resistive load cycle life is specified as 15A/125V AC for 100,000 cycles and 7.5A/250V AC for 100,000 cycles. The device also lists normally closed and normally open contact systems.\"}]","SEKI - Snap Action Thermostat Feature & Ratings | PDF",1787650661,5,{"code":4,"msg":31,"data":32},"ok",{"site_id":24,"language":23,"slug":33,"title":13,"keywords":34,"description":14,"schema_data":35,"social_meta":85,"head_meta":87,"extra_data":89,"updated_unix":28},"seki-snap-action-thermostat-feature-ratings","",{"@graph":36,"@context":84},[37,53,67],{"@type":38,"itemListElement":39},"BreadcrumbList",[40,44,47,50],{"item":41,"name":42,"@type":43,"position":20},"https://docshare.wps.com","Home","ListItem",{"item":45,"name":46,"@type":43,"position":21},"https://docshare.wps.com/document/","Document",{"item":48,"name":12,"@type":43,"position":49},"https://docshare.wps.com/document/technology/",3,{"item":51,"name":13,"@type":43,"position":52},"https://docshare.wps.com/document/seki-snap-action-thermostat-feature-ratings/141200/",4,{"url":51,"name":13,"@type":54,"author":55,"headline":13,"publisher":57,"fileFormat":60,"inLanguage":23,"description":14,"dateModified":61,"datePublished":61,"encodingFormat":60,"isAccessibleForFree":62,"interactionStatistic":63},"DigitalDocument",{"name":9,"@type":56},"Person",{"url":41,"name":58,"@type":59},"DocShare","Organization","application/pdf","2026-08-25",true,{"@type":64,"interactionType":65,"userInteractionCount":4},"InteractionCounter",{"@type":66},"ViewAction",{"@type":68,"mainEntity":69},"FAQPage",[70,76,80],{"name":71,"@type":72,"acceptedAnswer":73},"What safety design features do these SEKI snap action thermostats include?","Question",{"text":74,"@type":75},"They use IEC-standard safety design, with manual and automatic resettable options and a single-operation fuse disc. The contacts are configured to prevent closure until the specified temperature conditions are met.","Answer",{"name":77,"@type":72,"acceptedAnswer":78},"What is the temperature setting range and tolerance?",{"text":79,"@type":75},"The temperature setting range (at no load) is -20°C to 180°C. The indicated temperature tolerance is ±3°C and ±5°C, depending on the specification.",{"name":81,"@type":72,"acceptedAnswer":82},"What electrical and endurance ratings are provided?",{"text":83,"@type":75},"Resistive load cycle life is specified as 15A/125V AC for 100,000 cycles and 7.5A/250V AC for 100,000 cycles. The device also lists normally closed and normally open contact systems.","https://schema.org",{"og:url":51,"og:type":86,"og:title":13,"og:site_name":58,"og:description":14},"article",{"robots":88,"canonical":51},"index,follow",{"doc_id":7,"site_id":24},{"code":4,"msg":5,"data":91},[92,96,100,104,108,111,116,121,126,129,133],{"id":20,"doc_module":4,"doc_module_name":46,"category_name":93,"show_sort_weight":94,"slug":95},"Story & Novel",90,"story-novel",{"id":21,"doc_module":4,"doc_module_name":46,"category_name":97,"show_sort_weight":98,"slug":99},"Literature",80,"literature",{"id":52,"doc_module":4,"doc_module_name":46,"category_name":101,"show_sort_weight":102,"slug":103},"Exam",70,"exam",{"id":29,"doc_module":4,"doc_module_name":46,"category_name":105,"show_sort_weight":106,"slug":107},"Comic",60,"comic",{"id":11,"doc_module":4,"doc_module_name":46,"category_name":12,"show_sort_weight":109,"slug":110},50,"technology",{"id":112,"doc_module":4,"doc_module_name":46,"category_name":113,"show_sort_weight":114,"slug":115},7,"Healthcare",40,"healthcare",{"id":117,"doc_module":4,"doc_module_name":46,"category_name":118,"show_sort_weight":119,"slug":120},8,"Research & Report",30,"research-report",{"id":122,"doc_module":4,"doc_module_name":46,"category_name":123,"show_sort_weight":124,"slug":125},9,"Religion & Spirituality",20,"religion-spirituality",{"id":124,"doc_module":4,"doc_module_name":46,"category_name":127,"show_sort_weight":124,"slug":128},"World Cup","world-cup",{"id":130,"doc_module":4,"doc_module_name":46,"category_name":131,"show_sort_weight":130,"slug":132},10,"Lifestyle","lifestyle",{"id":134,"doc_module":4,"doc_module_name":46,"category_name":135,"show_sort_weight":29,"slug":136},19,"General","general"]