[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664196-105":59,"doc-detail-664196-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","section-2-general-design-requirements-drawing-standards-section-21-23","SECTION 2 - GENERAL DESIGN REQUIREMENTS - DRAWING STANDARDS - Section 2.1-2.3","","Section 2 sets general design and drawing standards for engineering drawings tied to development approval and municipal works and services in the Town of Ladysmith. It defines the scope, required components of a complete construction drawing set, allowed drawing size and production methods (computer or manual with reproducible black ink on Mylar), and mandatory presentation rules for scales, dimensions, lettering, neatness, and plan/profile layout. It also specifies relevant standards, datum/elevation notes, title block contents, required site-plan notes, and requirements for engineer seal, as-built file numbering, and decimal precision of numerical values.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/section-2-general-design-requirements-drawing-standards-section-21-23/664196/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/section-2-general-design-requirements-drawing-standards-section-21-23/664196.png","ImageObject",300,407,{"name":92,"@type":93},"Noah","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What drawings are included in a complete set for construction drawings under Section 2.2?","Question",{"text":112,"@type":113},"A complete set may include separate drawings covering site plan and key plan, landscaping, drainage area, roads and profiles, sanitary sewers and watermains profiles, common trench sanitary and storm profiles, street lighting/utilities plans, and additional special details with cross-sections.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What drawing formats and methods are required for submittal?",{"text":117,"@type":113},"Drawings must be prepared using computer or manual drafting methods with reproducible black drawing ink on Mylar. Pencil drawings are not accepted, and computer drafting is the desired standard for drawings submitted to the Town of Ladysmith.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the key requirements for lettering, scaling, and dimensions?",{"text":121,"@type":113},"Graphical scales must be indicated on reproducible drawings to support scaling and microfilm reproduction. Lettering must be done carefully to allow clear one-half size reduction, meeting microfilm reduction/blow-back quality requirements, and drawing scales and dimensions must be shown.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664196,1793243872,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":41},8796095462418,"https://ap-avatar.wpscdn.com/avatar/80000253c1241d02b47?x-image-process=image/resize,m_fixed,w_180,h_180&k=1778826106357471780","S E C T I O N 2  \nGENERAL DESIGN REQUIREMENTS  \nDRAWING STANDARDS  \n2.1 Scope  \n2.2 General Requirements  \n2.3 Site Plan and Key Plan  \n2.4 Drainage Area Plan  \n2.5 Building Grade Plan  \n2.6 Plan and Profile Drawings-General  \n2.7 Roads  \n2.8 Storm and Sanitary Sewers  \n2.9 Waterworks  \n2.10 Street Lighting, B.C. Hydro, B.C. Telephone, Gas  \n2.11 Detail Sheet and Cross-Sections  \n2.12 As-Built Drawings  \n2.13 Revised Site Plan  \n2.14 Computer Drafting Standards  \nGENERAL  \n2.15 Certification of Works  \n2.16 Survey Control Monuments  \nSTANDARD DRAWINGS  \nG1 Graphic Scale and Register Marks  \nG2 Standard Drawing Symbols and Abbreviations  \nG2A Standard Drawing Symbols and Abbreviations G5 Survey Monument-Flush Mounted G6 Survey Monument-Box Type G7 Survey Monument-Box Casting Detail  \nTOWN OF LADYSMITH STANDARDS AND SPECIFICATIONS 2-1  \nS E C T I O N 2  \nGENERAL DESIGN REQUIREMENTS  \nDRAWING STANDARDS  \n2.1  SCOPE  \nThis section shall govern the preparation of engineering drawings associated with development approval and the Municipal works and services.  \n2.2  GENERAL REQUIREMENTS  \nA complete set of construction drawings shall consist of separate drawings of some or all ofthe following:  \n(a) Site plan and key plan.  \n(b) Landscaping plan (see Parks and Recreation Dept. Landscaping Guidelines) .  \n(c) Drainage area plan.  \n(d) Plan and profile for roads, drainage and storm sewers.  \n(e) Plan and profile for sanitary sewers and watermains.  \n(f) Plan and profile for sanitary and storm sewers for common trench designs.  \n(g) Plan of proposed street lighting, hydro, telephone, cablevision and gas.  \n(h) Additional plans showing any special details and cross-sections.  \n2.2.1 Maximum drawing size shall be 6l0 mm x 9l5 mm.  \n2.2.2 Drawings shall be prepared by utilizing computer or manual drafting methods using reproducible black drawing ink on Mylar. Pencil drawings will not be accepted. Computer drafting methods as per Section 2.12 are the desired standard for all drawings submitted to the Town of Ladysmith.  \n2.2.3 Drawing scales and dimensions shall be shown. To facilitate scaling and to allow for reproductions from microfilm, graphical scales shall be indicated on all reproducible drawings. Bar scales, 50 mm long, divided at l0 mm intervals shall be drawn on each drawing sheet, as shown on Standard Drawing Gl.  \n2.2.4 In all cases lettering shall be done with sufficient care to permit clear, one-half size reduction. The quality of the character definition shall be such that drawings maybe reduced to 35 mm microfilm and blown back full size by micro-reproduction process without showing evidence of filled-in loops or leaching of character to character and line to line.  \n2.2.5 The drawings shall be neat and legible and they shall clearly locate and describe the work in sufficient detail to facilitate construction, with clearly defined limits of construction.  \n2-2 TOWN OF LADYSMITH STANDARDS AND SPECIFICATIONS  \n2.2.6 Plan profile drawings shall be drawn with the profile on the bottom of the drawing sheet.  \n2.2.7 Lettering on drawings shall conform to Canadian General Standards Board Standard CAN2-72.7-M78 unless otherwise noted in these standards.  \n2.2.8 Standard drafting procedures shall be used for dimensioning, arrowheads, line densities, etc. Lettering shall be to Leroy metric heights and widths with the minimum height of lettering being 2.5 mm. Vertical upper case lettering is preferred. Conflicts between linework, symbols, dimensioning or textshall be removed.  \n2.2.9 All elevations shown on drawings shall be metric geodetic datum and the source and location of datum shall be clearly noted on each drawing.  \n2.2.10 Drawing title block shall include the project name, project location, type of drawing (i.e. Site Plan) and Engineer's name and/or company name and logo.  \n2.2.11 Plan and Profile drawings shall be to the following scales unless otherwise approved:  \nHorizontal l:500 or l:250  \nVertical l:50  \n2.2.12 The follo","cbCaioXPr9Rje48M","https://ap.wps.com/l/cbCaioXPr9Rje48M","pdf",64061,12,"English","# 2.1 Scope\n# 2.2 General Requirements\n## 2.2.1 Maximum drawing size\n## 2.2.2 Drawing production methods\n## 2.2.3 Drawing scales and dimensions\n## 2.2.4 Lettering and reduction requirements\n## 2.2.5 Neatness, legibility, and construction limits\n## 2.2.6 Plan/profile layout\n## 2.2.7 Lettering standard CAN2-72.7-M78\n## 2.2.8 Drafting procedures and lettering size\n## 2.2.9 Metric geodetic datum for elevations\n## 2.2.10 Drawing title block contents\n## 2.2.11 Plan/profile drawing scales\n## 2.2.12 Required notes on site plan\n## 2.2.13 Standard details and symbols\n## 2.2.14 Engineer seal and signature\n## 2.2.15 As-built file number placement\n## 2.2.16 Decimal precision of numerical values\n# 2.3 Site Plan and Key Plan","[{\"question\":\"What drawings are included in a complete set for construction drawings under Section 2.2?\",\"answer\":\"A complete set may include separate drawings covering site plan and key plan, landscaping, drainage area, roads and profiles, sanitary sewers and watermains profiles, common trench sanitary and storm profiles, street lighting/utilities plans, and additional special details with cross-sections.\"},{\"question\":\"What drawing formats and methods are required for submittal?\",\"answer\":\"Drawings must be prepared using computer or manual drafting methods with reproducible black drawing ink on Mylar. Pencil drawings are not accepted, and computer drafting is the desired standard for drawings submitted to the Town of Ladysmith.\"},{\"question\":\"What are the key requirements for lettering, scaling, and dimensions?\",\"answer\":\"Graphical scales must be indicated on reproducible drawings to support scaling and microfilm reproduction. Lettering must be done carefully to allow clear one-half size reduction, meeting microfilm reduction/blow-back quality requirements, and drawing scales and dimensions must be shown.\"}]","SECTION 2 - GENERAL DESIGN REQUIREMENTS - DRAWING STANDARDS - Section 2.1-2.3 | PDF"]