[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663256-105":59,"doc-detail-663256-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","section-14-2100-machine-room-less-mrl-traction-elevators-part-1-general","SECTION 14 2100 - MACHINE-ROOM-LESS (MRL) TRACTION ELEVATORS - Part 1 - General","","Section 14 2100 covers the design, fabrication, installation, testing, adjusting, and ongoing maintenance of machine-room-less traction passenger/service elevators. It specifies furnished elevator components including traction machine, overspeed safety elements, brakes, buffers, guide rails, controls, cab and doors, hoistway elements, counterweights, and required hardware to deliver complete operational equipment. The contractor must provide testing, twelve-month preventive maintenance, and deliver certificates, manuals, schematics, software documentation, and “As-Built” shop drawings within 30 days of final acceptance, while coordinating permits and inspections and observing related division sections.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/section-14-2100-machine-room-less-mrl-traction-elevators-part-1-general/663256/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/section-14-2100-machine-room-less-mrl-traction-elevators-part-1-general/663256.png","ImageObject",300,407,{"name":92,"@type":93},"SANS","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the scope of Section 14 2100 for MRL traction elevators?","Question",{"text":112,"@type":113},"The section covers design, fabrication, installation, testing, adjusting, and maintenance of machine-room-less traction passenger/service elevator equipment where the elevators are shown on the drawings.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What deliverables are required from the contractor after final acceptance?",{"text":117,"@type":113},"Within 30 days of final acceptance, the contractor must furnish certificates, instruction manuals, schematic diagrams, software documentation, and “As-Built” shop drawings to the owner.",{"name":119,"@type":110,"acceptedAnswer":120},"Which codes and standards must be complied with on the Evanston campus and Chicago campus?",{"text":121,"@type":113},"Both campuses require compliance with the most stringent applicable provisions, including ASME A17 safety codes, NFPA 70, International Building Code, NFPA 101, and accessibility requirements; specific electrical and building code references differ by campus (Evanston vs Chicago).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663256,1793226072,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":41,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},962090760505,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","NORTHWESTERN UNIVERSITY  \nPROJECT NAME JOB \\#    \n____________  \nFOR:    \nISSUED: 2024.1  \nSECTION 14 2100-MACHINE-ROOM-LESS (MRL) TRACTION ELEVATORS  \nPART 1-GENERAL  \n1.1 RELATED DOCUMENTS  \nA. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.  \n1.2 SUMMARY  \nA. Section applies to design, fabrication, installation, testing, adjusting and maintenance of machine-room-less traction passenger/service elevator equipment. Elevator(s) shall be provided where shown on the drawings.  \nB. Work: The work shall include, but not be limited to the following for Elevators \u003CInsert Elevator Numbers> .  \n1. A machine-room-less traction passenger elevator(s), complete with electrically operated geared traction machine, overspeed safety, overspeed governor, brakes, buffers, guide rails, signal fixtures, control equipment, elevator car, sling, platform, cab interior, handrails, car doors, hoistway doors, counterweights, cables, and all hardware required to provide a complete and fully operational passenger elevator.  \n2. Testing and adjustment of all elevator related controls and equipment.  \n3. Preventive maintenance and maintenance service for a twelve month period shall be provided by the Contractor, beginning at the time of written Final Acceptance of the work by Owner.  \n4. Contractor shall furnish to the Owner all appropriate certificates, instruction manuals, schematic diagram, software documentation, and shop drawings indicating \"As-Built\"conditions, within 30 days of final acceptance of the work.  \n5. Contractor shall be responsible for obtaining and payment of any required installation/building permits and inspection fees for the installation of the elevator(s) .  \nC. Location: The work shall be performed at the \u003Cbuilding name> , \u003Cbuilding legal address> ,\u003CCity>, Illinois.  \nD. Document Review: Contractor shall review contract documents and any existing conditions in order to identify conflicts with their products which might create construction problems.  \nE. Related Requirements:  \n1. Section 015000 \"Temporary Facilities and Controls\" for temporary use of elevators for construction purposes.  \n2. Section 033000 \"Cast-in-Place Concrete\" for setting sleeves, inserts, and anchoring devices in concrete.  \n3. Section 042000 \"Unit Masonry\" for setting sleeves, inserts, and anchoring devices in masonry and for grouting elevator entrance frames installed in masonry walls.  \n4. Section 051200 \"Structural Steel Framing\" for the following:  \nMACHINE-ROOM-LESS (MRL) TRACTION ELEVATORS 14 2120-1  \nNORTHWESTERN UNIVERSITY  \nPROJECT NAME JOB \\#    \n____________  \nFOR:    \nISSUED: 2024.1  \na. Attachment plates, angle brackets, and other preparation of structural steel for fastening guide-rail brackets.  \nb. Divider beams.  \nc. Hoist beams.  \nd. Structural-steel shapes for subsills.  \n5. Section 055000 \"Metal Fabrications\" for the following:  \na. Attachment plates and angle brackets for supporting guide-rail brackets.  \nb. Divider beams.  \nc. Hoist beams.  \nd. Structural-steel shapes for subsills.  \ne. Pit ladders.  \nf. Cants in hoistways made from steel sheet.  \n6. Section 055213 \"Pipe and Tube Railings\" for railings between adjacent elevator pits.  \n7. \u003CInsert Section number>-\u003CInsert Section title> for finish flooring in elevator cars.  \n8. Section 102213 \"Wire Mesh Partitions\" for guards between adjacent elevator pits.  \n9. Section 221429 \"Sump Pumps\" for sump pumps, sumps, and sump covers in elevator pits.  \n10. Section 271500 \"Communications Horizontal Cabling\" for telephone/text/camera service for elevators  \n11. [Section 283111 \"Digital, Addressable Fire-Alarm System\"] [Section 283112 \"Zoned (DC Loop)] Fire-Alarm System\" for smoke detectors in elevator lobbies to initiate emergency recall operation[ and heat detectors in machine spaces/hoistways and control rooms to disconnect power from elevator equipment before sprinkler activation] a","cbCailGlxpSdMDyg","https://ap.wps.com/l/cbCailGlxpSdMDyg","pdf",238677,"English","# 1.1 Related Documents\n# 1.2 Summary\n## A. Scope of Work\n## B. Elevator Work Includes\n## C. Location\n## D. Document Review\n## E. Related Requirements\n# 1.3 Definitions\n# 1.4 Codes and Standards (Evanston Campus)\n# 1.5 Codes and Standards (Chicago Campus)","[{\"question\":\"What is the scope of Section 14 2100 for MRL traction elevators?\",\"answer\":\"The section covers design, fabrication, installation, testing, adjusting, and maintenance of machine-room-less traction passenger/service elevator equipment where the elevators are shown on the drawings.\"},{\"question\":\"What deliverables are required from the contractor after final acceptance?\",\"answer\":\"Within 30 days of final acceptance, the contractor must furnish certificates, instruction manuals, schematic diagrams, software documentation, and “As-Built” shop drawings to the owner.\"},{\"question\":\"Which codes and standards must be complied with on the Evanston campus and Chicago campus?\",\"answer\":\"Both campuses require compliance with the most stringent applicable provisions, including ASME A17 safety codes, NFPA 70, International Building Code, NFPA 101, and accessibility requirements; specific electrical and building code references differ by campus (Evanston vs Chicago).\"}]","SECTION 14 2100 - MACHINE-ROOM-LESS (MRL) TRACTION ELEVATORS - Part 1 - General | PDF",76]