[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648841-105":59,"doc-detail-648841-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","section-07-6200-sheet-metal-flashing-and-trim-part-1-general-sheet-metal-performance-requirements-and-submittals","SECTION 07 6200-SHEET METAL FLASHING AND TRIM - Part 1 General - Sheet Metal Performance Requirements and Submittals","","Section 07 6200 specifies formed reglets, counterflashing, and sheet metal fabrications for both low- and steep-slope roofs, roof drainage, and wall sheet metal applications. It defines required terminology and standards references, sets general performance expectations for uplift resistance, thermal movement, weather exposure, watertightness, and material compatibility. The section also establishes submittals including product data, shop drawings, samples, warranty samples, and maintenance data, plus quality assurance criteria based on SMACNA, CDA, and wind-pressure testing standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/section-07-6200-sheet-metal-flashing-and-trim-part-1-general-sheet-metal-performance-requirements-and-submittals/648841/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/section-07-6200-sheet-metal-flashing-and-trim-part-1-general-sheet-metal-performance-requirements-and-submittals/648841.png","ImageObject",300,407,{"name":92,"@type":93},"Connor ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-24","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does Section 07 6200 include for sheet metal work?","Question",{"text":112,"@type":113},"It includes formed reglets and counterflashing, formed roof drainage sheet metal fabrications, formed low-slope and steep-slope roof sheet metal fabrications, and formed wall sheet metal fabrications.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the performance requirements for installed sheet metal?",{"text":117,"@type":113},"Installed sheet metal must withstand specified uplift pressures, thermally induced movement, and weather exposure without failure due to defective manufacture, fabrication, installation, or other construction defects, while remaining watertight.",{"name":119,"@type":110,"acceptedAnswer":120},"What submittals are required under this section?",{"text":121,"@type":113},"Product data, shop drawings showing installation layouts and details, samples for exposed products and finishes, a sample of special warranty, and maintenance data are required.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648841,1792855155,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},687207022233,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","SECTION 07 6200-SHEET METAL FLASHING AND TRIM  \nMaintain Section format, including the UH master spec designation and version date in the center columns of the header and footer. Complete the header and footer with Project information.  \nRevise this Section by deleting and inserting text to meet Project-specific requirements.  \nThis Section uses the term \"Architect\" or “Engineer.” Change this term to match that used to identify the design professional as defined in the General and Supplementary Conditions.  \nVerify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed.  \nDelete hidden text after this Section has been edited for the Project.  \nPART 1-GENERAL  \n1.1 RELATED DOCUMENTS  \nA. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.  \nB. The Contractor's attention is specifically directed, but not limited, to the following documents for additional requirements:  \n1. The current version of the Uniform General Conditions for Construction Contracts, State of Texas, available on the web site of the Texas Facilities Commission.  \n2. The University of Houston’s Supplemental General Conditions and Special Conditions for Construction.  \n1.2 SUMMARY  \nA. Section includes:  \n1. Formed reglets and counterflashing.  \n2. Formed roof drainage sheet metal fabrications.  \n3. Formed low-slope roof sheet metal fabrications.  \n4. Formed steep-slope roof sheet metal fabrications.  \n5. Formed wall sheet metal fabrications.  \n1.3 DEFINITIONS  \nA. Sheet Metal Terminology: See Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA)“Architectural Sheet Metal Manual – Sixth Edition” for definition of terms related to work in this Section.  \n1.4 PERFORMANCE REQUIREMENTS  \nSelect first or second option in Paragraph below as appropriate for Project. If second option is selected ensure uplift pressures are, in fact, on the Drawings.  \nA. General Performance: Installed sheet metal shall withstand specified uplift pressures [Insert pressures] [as indicated on Drawings], thermally induced movement, and exposure to weather without failure due to defective manufacture, fabrication, installation, or other defects in construction. Sheet metal units shall remain watertight.  \nB. Material Compatibility: Provide sheet metal materials that are compatible with one another under conditions of service and application required, as demonstrated by the sheet metal manufacturer based on testing and field experience.  \nC. Comply with governing codes and regulations. Use experienced installers.  \nDeliver, handle and store materials in accordance with manufacturer's  \ninstructions.  \nD. Clear Lake Campus to meet the requirements of the Texas Windstorm Act.  \nE. Reference Standards: Applicable portions of SMACNA, ANSI/SPRI ES-1, ASTM and NAAMM publications.  \n1.5 SUBMITTALS  \nA. Product Data: For each type of product indicated. Include material descriptions, ASTM standards, and dimensions of individual components and profiles.  \nB. Shop Drawings: Show installation layouts of sheet metal flashing and trim, including plans, elevations, expansion-joint locations, and keyed details. Distinguish between shop-and field-assembled work.  \n1. Submit the following: Include details for forming, joining, supporting, and securing sheet metal flashing and trim, including pattern of seams, termination points, fixed points, expansion joints, expansion-joint covers, edge conditions, special conditions, and connections to adjoining work.  \na. Counterflashing at roof edges  \nb. Coping and drip edge at roof edges  \nc. Counterflashing at doors/windows for protection of waterproofing  \nd. Receiver sections  \ne. Counterflashing at elevation transitions (doors to perimeter edges)  \nf. Through-wall flashing pans  \ng. Roof expansion joints  \nh. Penetration flashing (including rain hoods)  \nC. Sample","cbCaiq4VqtqRqyKY","https://ap.wps.com/l/cbCaiq4VqtqRqyKY","pdf",243848,17,"English","# PART 1-GENERAL\n## 1.1 RELATED DOCUMENTS\n## 1.2 SUMMARY\n## 1.3 DEFINITIONS\n## 1.4 PERFORMANCE REQUIREMENTS\n## 1.5 SUBMITTALS\n## 1.6 QUALITY ASSURANCE","[{\"question\":\"What does Section 07 6200 include for sheet metal work?\",\"answer\":\"It includes formed reglets and counterflashing, formed roof drainage sheet metal fabrications, formed low-slope and steep-slope roof sheet metal fabrications, and formed wall sheet metal fabrications.\"},{\"question\":\"What are the performance requirements for installed sheet metal?\",\"answer\":\"Installed sheet metal must withstand specified uplift pressures, thermally induced movement, and weather exposure without failure due to defective manufacture, fabrication, installation, or other construction defects, while remaining watertight.\"},{\"question\":\"What submittals are required under this section?\",\"answer\":\"Product data, shop drawings showing installation layouts and details, samples for exposed products and finishes, a sample of special warranty, and maintenance data are required.\"}]","SECTION 07 6200-SHEET METAL FLASHING AND TRIM - Part 1 General - Sheet Metal Performance Requirements and Submittals | PDF",1792795719,43]