[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648856-105":59,"doc-detail-648856-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","section-06-4116-plastic-laminate-clad-architectural-casework","SECTION 06 4116 - PLASTIC-LAMINATE-CLAD ARCHITECTURAL CASEWORK","","Specification section for plastic-laminate-faced wood casework and related components, including casework hardware, mounting boards, countertops, and accessory items. Defines modular design criteria with interchangeable cabinet modules, quality and certification standards, required reference benchmarks, and product definitions such as HPDL and FSC chain-of-custody. Covers submittals, samples, manufacturer/installer qualifications, delivery, storage, handling, site ambient conditions, and warranties, with strict coordination against other CSI MasterFormat sections.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/section-06-4116-plastic-laminate-clad-architectural-casework/648856/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/section-06-4116-plastic-laminate-clad-architectural-casework/648856.png","ImageObject",300,407,{"name":92,"@type":93},"Nguyễn Văn Học","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-24","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What items are included in this plastic-laminate-clad casework section?","Question",{"text":112,"@type":113},"It includes plastic-laminate-faced wood casework, countertops, mounting boards, and casework hardware, along with modular units such as floor base units, wall-suspended base units, uppers, tall storage, and specialty items.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What submittals and samples are required?",{"text":117,"@type":113},"Product data must include component dimensions, configurations, construction details, joint details, attachments, and service requirements/locations. Shop drawings must show casework locations and rough-in/anchor placement dimensions and tolerances. Samples include two samples (minimum 12 x 12 inches) for each laminate color, plus selection samples for each countertop with manufacturer color chips.",{"name":119,"@type":110,"acceptedAnswer":120},"What site conditions must be met before delivery and installation?",{"text":121,"@type":113},"Casework must not be delivered or installed until concrete, masonry, and drywall/plaster are dry, ambient relative humidity is maintained between 25–55 percent, and temperature is controlled above 55°F. Noncompliant conditions require a release letter from the general contractor or owner.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648856,1792876248,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},1374402739827,"https://ap-avatar.wpscdn.com/avatar/14000c97e7351f1a627?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787885694763230660","SECTION 06 4116  \nPLASTIC-LAMINATE-CLAD ARCHITECTURAL CASEWORK  \n[ALTERNATE SPECIFICATION LOCATION]  \nSECTION 12 3216  \nPLASTIC-LAMINATE-CLAD ARCHITECTURAL CASEWORK  \nSpecifier Note: Specification is based on Steelcase Health: Convey product line. Copy and edit into this section as needed for casework that cannot be described on the drawings.  \nSpecifier Notes: This Product Guide Specification is written according to the Construction Specifications Institute (CSI) format, Including MasterFormat, Section Format, and Page Format, as described in the project resource guide-the Project Delivery Practice Guide.  \nSection numbers are from CSI's MasterFormat.  \nThis section must be carefully reviewed and edited by the architect to meet the requirements of the project and local building codes. Coordinate this section with other specification sections and drawings. Delete all \"Specifier Notes\" when editing this section.  \nPART 1 GENERAL  \n1.01 SECTION INCLUDES  \nSpecifier Note: Steelcase Convey modular HPDL casework includes floor base units, wall-suspended base units, uppers, tall storage, specialty items, countertops, and miscellaneous items.  \nA. Plastic-Laminate-Faced Wood Casework.  \nB. Countertops.  \nC. Mounting Boards.  \nD. Casework hardware.  \n1.02 RELATED REQUIREMENTS  \nA. Section 06 1000-Rough Carpentry: Wood blocking for anchoring casework.  \nB. Section 07 9200-Joint Sealants: Sealing joints between casework and countertops and adjacent walls, floors, and ceilings.  \nC. Section 09 2116-Gypsum Board Assemblies: Reinforcement in metal framed partitions for anchoring casework.  \nD. Section 09 6500-Resilient Flooring: Resilient base applied to casework.  \nE. Section 10 2219-Demountable Partitions.  \nF. Section 12 3216-Manufactured Plastic-Laminate-Clad Casework.  \nG. Section 12 3600-Countertops: Countertops not specified in this section.  \nH. Division 22-Plumbing: Service fittings and outlets.  \nI. Division 26-Electrical  \n1.03 REFERENCE STANDARDS  \nA. ANSI A135 .4-American National Standard for Basic Hardboard.  \nB. ANSI A208 .1-American National Standard for Particleboard.  \nC. ANSI A208 .2-American National Standard for Medium Density Fiberboard.  \nD. ANSI/BIFMA e3-Furniture Sustainability Standard; 2012.  \nE. ASTM E84-Standard Test Method for Surface Burning Characteristics of Building Materials.  \nF. AWI/AWMAC/WI (AWS) -Architectural Woodwork Standards  \nG. BHMA A156 .9-American National Standard for Cabinet Hardware.  \nH. ISFA 2-01-Classification and Standards for Solid Surfacing Material.  \nI. NEMA LD 3-High-Pressure Decorative Laminates.  \nJ. SEFA 8PL-Scientific Equipment and Furniture Association: Plastic laminate Grade Casework; 2010.  \n1.04 DEFINITIONS  \nA. HPDL-High Pressure Decorative Laminate.  \nB. FSC-Forrest Stewardship Council: Chain-of-custody.  \nC. MR-Moisture Resistant.  \nD. PP-Polypropylene  \nE. PVC-Poly-vinyl chloride  \nF. MDF-Medium Density Fiberboard  \n1.05 SUBMITTALS  \nA. See Section 01 3000-Administrative Requirements, for submittal procedures.  \nB. Product Data: Provide component dimensions, configurations, construction details, joint details, and attachments, utility and service requirements and locations.  \nC. Shop Drawings: Indicate casework locations, large scale plans, elevations, cross sections, rough-in and anchor placement dimensions and tolerances, clearances required.  \nD. Samples: Submit two samples, minimum size 12 x 12 inch (305 x 305 mm) of each color of base plastic laminate, or other finish.  \nE. Selection Samples: For each countertop specified, color chips representing manufacturer's full range of available colors and patterns.  \n1.06 QUALIFICATIONS  \nA. Manufacturer: Company regularly engaged in design and manufacture of products specified in this section and scope of work similar to requirements of this project.  \nB. Installer: Company that has successfully completed projects of the type and scope similar to the requirements of this project.  \n1.07 DELIVERY, STORAGE, AND HANDLING  \nA","cbCaia1Xh3DrqhYk","https://ap.wps.com/l/cbCaia1Xh3DrqhYk","pdf",118722,"English","# PART 1 GENERAL\n## 1.01 SECTION INCLUDES\n## 1.02 RELATED REQUIREMENTS\n## 1.03 REFERENCE STANDARDS\n## 1.04 DEFINITIONS\n## 1.05 SUBMITTALS\n## 1.06 QUALIFICATIONS\n## 1.07 DELIVERY, STORAGE, AND HANDLING\n## 1.08 SITE CONDITIONS\n## 1.09 WARRANTY\n# PART 2 PRODUCTS\n## 2.01 MANUFACTURERS\n## 2.02 CASEWORK, GENERAL","[{\"question\":\"What items are included in this plastic-laminate-clad casework section?\",\"answer\":\"It includes plastic-laminate-faced wood casework, countertops, mounting boards, and casework hardware, along with modular units such as floor base units, wall-suspended base units, uppers, tall storage, and specialty items.\"},{\"question\":\"What submittals and samples are required?\",\"answer\":\"Product data must include component dimensions, configurations, construction details, joint details, attachments, and service requirements/locations. Shop drawings must show casework locations and rough-in/anchor placement dimensions and tolerances. Samples include two samples (minimum 12 x 12 inches) for each laminate color, plus selection samples for each countertop with manufacturer color chips.\"},{\"question\":\"What site conditions must be met before delivery and installation?\",\"answer\":\"Casework must not be delivered or installed until concrete, masonry, and drywall/plaster are dry, ambient relative humidity is maintained between 25–55 percent, and temperature is controlled above 55°F. Noncompliant conditions require a release letter from the general contractor or owner.\"}]","SECTION 06 4116 - PLASTIC-LAMINATE-CLAD ARCHITECTURAL CASEWORK | PDF",1792795800,15]