[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648794-105":59,"doc-detail-648794-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","section-05100-structural-steel-execution-requirements","SECTION 05100 - Structural Steel - Execution Requirements","","Section 05100 specifies furnishing and erecting structural steel in accordance with contract documents and engineer directions, including fabrication and erection per AISC provisions. It defines related work for painting, inspection and quality assurance for materials, shop and field welds, and bolted joints under AWS and AISC RCSC standards. It details required shop drawings and certificates of compliance, material conformance for steel plates, bolts, washers, tubing, and pipe under ASTM/ASME standards. It further outlines design criteria, fabrication practices, welding requirements, coatings, painting, delivery and storage, member marking, and erection procedures.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/section-05100-structural-steel-execution-requirements/648794/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/section-05100-structural-steel-execution-requirements/648794.png","ImageObject",300,407,{"name":92,"@type":93},"The UK Girl","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What standards govern the fabrication and erection of structural steel in Section 05100?","Question",{"text":112,"@type":113},"Fabrication and erection follow AISC specifications for design, fabrication, and erection of structural steel for buildings and the code of standard practice for steel buildings and bridges, with connection design following AISC full strength requirements when not shown on the plans.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How are welds and bolted construction inspected and verified?",{"text":117,"@type":113},"The engineer inspects materials and work for compliance with contract documents. Shop and field welds may be inspected under AWS D1.1, and welds needing repairs are reinspected after repairs. Field assembled bolted construction may be inspected under AISC RCSC specifications for structural joints using high-strength bolts.",{"name":119,"@type":110,"acceptedAnswer":120},"What materials and fasteners are required to meet ASTM/ASME requirements?",{"text":121,"@type":113},"Structural steel shapes, plates, and bars conform to ASTM A36 unless otherwise noted. Bolts, nuts, and washers meet ASME B18.2.1 and B18.2.2, with low-carbon bolts/nuts to ASTM A307 and high-strength structural joint bolts, nuts, and washers to ASTM F3125 Grade A325 only; round and beveled washer requirements are also specified under ASTM F844 and geometry rules.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648794,1793065540,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},2199028711991,"https://us-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","05100-1 of 5  \nSECTION 05100  \nSTRUCTURAL STEEL  \n05100.01 GENERAL  \nA. Description  \nStructural steel shall include, but not necessarily be limited to, furnishing and erecting structural steel in accordance with the Contract Documents, or as directed by the Engineer. Structural steel shall be fabricated and erected in accordance with the AISC “Specifications for the Design, Fabrication and Erection of Structural Steel for Buildings” and the “Code of Standard Practice for Steel Buildings and Bridges”.  \nB. Related Work Included Elsewhere  \nPainting; Section 09900.  \nC. Quality Assurance  \n1. The Engineer will inspect all materials and work to ensure compliance with the Contract Documents.  \n2. Shop and field welds may be inspected in accordance with AWS D 1.1. Welds requiring repairs will be reinspected after repairs are made.  \n3. Field assembled bolted construction may be inspected in accordance with AISC\"RCSC Specifications for Structural Joints Using High-Strength Bolts\".  \nD. Submittals  \n1. Shop Drawings  \nShop drawings shall be submitted as specified in the \"General Provisions\" for all structural steel. The shop drawings shall include the following information:  \na. Complete information necessary for the fabrication of the component parts of the structure or structures, including location, type and size of all bolts and shop welds. Welds shall be indicated by standard AWS welding symbols.  \nb. Erection plans and details indicating required sequence of construction and temporary bracing where applicable.  \nc. Surface finishes, shop paint system or other coating as specified in Section  \n05100.03 and/or 09900.03.  \nPublished: 01/01 Revised: 04/24  \nSTRUCTURAL STEEL 05100-2 of 5  \n2. Certificates of Compliance  \nCertificates of compliance shall be submitted as specified in the \"General Provisions\"for all structural steel stating that the material furnished meets the requirements specified in Section 05100.02.  \n05100.02 MATERIALS  \nA. Materials Furnished by the County  \nThe County will not furnish any structural steel.  \nB. Contractor's Options  \nNot applicable.  \nC. Detailed Material Requirements  \n1. Structural Steel  \nCarbon steel plates, shapes, and bars shall conform to requirements ofASTM A 36 unless otherwise noted on the Plans.  \n2. Bolts, nuts, and washers shall meet requirements of ASME B 18.2.1 and B 18.2.2 and the following:  \na. Low carbon steel bolts and nuts shall conform to requirements ofASTM A 307.  \nb. High strength carbon steel bolts, nuts, and washers for structural joints shall conform to requirements ofASTM F3125, Grade A 325 only.  \nc. Round washers other than those in contact with high strength bolt heads and nuts shall conform to requirements ofASTM F 844.  \nd. Beveled washers shall be square, smooth, and sloped to make contact surfaces of bolt head and nut parallel.  \n3. Structural steel tubing in round, square, or rectangular tube shapes shall conform to requirements of ASTM A 500, Grade C. Round pipe shall conform to the requirements ofASTM A 53, Grade B.  \nPublished: 01/01 Revised: 04/24  \nSTRUCTURAL STEEL 05100-3 of 5  \n05100.03 EXECUTION  \nA. Design Criteria  \nDesign of connections not shown on the Plans shall be in accordance with requirements of\"Specifications for Structural Steel for Buildings\" of the AISC for the full strength of the member.  \nB. Fabrications  \n1. Fabricate and shop assemble work in accordance with AISC \"Specifications for Structural Steel for Buildings\", \"RCSC Specification for Structural Joints using High-Strength Bolts\".  \n2. Straighten rolled material, if necessary, before it is laid out for fabrication in a manner conforming to the mill tolerances provided in ASTM A 6, and by a process and in a manner which will not injure the material. Sharp kinks and bends will because for rejection of the material. Heat shrinking of low-alloy structural steel will not be permitted.  \n3. Perform shearing, flame cutting, and chipping carefully and accurately. Cut flamecut edges of ","cbCaisiit9QhExN5","https://ap.wps.com/l/cbCaisiit9QhExN5","pdf",121576,"English","# 05100 Structural Steel\n## 05100.01 General\n## 05100.02 Materials\n## 05100.03 Execution","[{\"question\":\"What standards govern the fabrication and erection of structural steel in Section 05100?\",\"answer\":\"Fabrication and erection follow AISC specifications for design, fabrication, and erection of structural steel for buildings and the code of standard practice for steel buildings and bridges, with connection design following AISC full strength requirements when not shown on the plans.\"},{\"question\":\"How are welds and bolted construction inspected and verified?\",\"answer\":\"The engineer inspects materials and work for compliance with contract documents. Shop and field welds may be inspected under AWS D1.1, and welds needing repairs are reinspected after repairs. Field assembled bolted construction may be inspected under AISC RCSC specifications for structural joints using high-strength bolts.\"},{\"question\":\"What materials and fasteners are required to meet ASTM/ASME requirements?\",\"answer\":\"Structural steel shapes, plates, and bars conform to ASTM A36 unless otherwise noted. Bolts, nuts, and washers meet ASME B18.2.1 and B18.2.2, with low-carbon bolts/nuts to ASTM A307 and high-strength structural joint bolts, nuts, and washers to ASTM F3125 Grade A325 only; round and beveled washer requirements are also specified under ASTM F844 and geometry rules.\"}]","SECTION 05100 - Structural Steel - Execution Requirements | PDF",1792795335,13]