[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-562849-105":59,"doc-detail-562849-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","sct-013-030-split-core-current-transformer-technical-specification","SCT-013-030 - Split-Core Current Transformer Technical Specification","","This technical specification document details the characteristics and performance parameters of the SCT-013-030 split-core current transformer manufactured by XiDi Technology. The device features an open size of 13mm by 13mm, utilizes a ferrite core, and conforms to UL 94-V0 fire resistance standards. It offers an input current range of 0-30A with a 0-1V voltage output. Key technical specifications included are a non-linearity of ±1%, a built-in sampling resistance of 62Ω, a turn ratio of 1800:1, and a wide operating temperature range from -25°C to +70°C, ensuring reliable performance in various environmental conditions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/sct-013-030-split-core-current-transformer-technical-specification/562849/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/sct-013-030-split-core-current-transformer-technical-specification/562849.png","ImageObject",300,407,{"name":92,"@type":93},"ahduag","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-14","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the input current range for the SCT-013-030?","Question",{"text":112,"@type":113},"The SCT-013-030 current transformer has an input current range of 0-30A.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the physical opening dimensions of the sensor?",{"text":117,"@type":113},"The sensor features an open size of 13mm by 13mm.",{"name":119,"@type":110,"acceptedAnswer":120},"What is the operating temperature range of this device?",{"text":121,"@type":113},"The device is designed to operate within a temperature range of -25°C to +70°C.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},562849,1792013571,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":81},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","# SPECIFICATION\n\nProduct Name:Sp1ilt-core current Name:Sp1ilt-core current  \nCustomer Title :XiDi Technology  \ntransformertransformer  \nManufacture Model :SCT-013-030  \nCharateristics:open size:13mm×13mm1m leading wireCore material:Ferrite  \nFire resistance property:in accordance withwithUL 94-VO  \nDielectric strength:1500V AC/1min 5mA(between shell and output)  \nOutline size diagram:(in mm)  \n0-30A0-30A  \nVoltage output typeVoltage output type  \n              Side ViewSchematic DiagramSchematic Diagram  \nFront View  \nTypical table of technical parameters:  \n\n| input current   | output voltage   | non-linearity   | build-in sampling resistance(RL)   |\n| --- | --- | --- | --- |\n| 0-30A   | 0-1V   | ±1%   | 62Ω   |\n| turn ratio   | resistance grade   | work temperature   | dielectric strength(between shell and output)   |\n| 1800:1   | Grade B   | -25℃～+70℃   | 1500V AC/1min 5mA   |\n\nCustomer Sign:  \nApprove Sign:Chenjianping  \n2011-7-21","cbCaii0sQv8lIJJO","https://ap.wps.com/l/cbCaii0sQv8lIJJO","pdf",247459,"English","# Product Overview\n## Technical Parameters\n## Physical Dimensions and Characteristics","[{\"question\":\"What is the input current range for the SCT-013-030?\",\"answer\":\"The SCT-013-030 current transformer has an input current range of 0-30A.\"},{\"question\":\"What are the physical opening dimensions of the sensor?\",\"answer\":\"The sensor features an open size of 13mm by 13mm.\"},{\"question\":\"What is the operating temperature range of this device?\",\"answer\":\"The device is designed to operate within a temperature range of -25°C to +70°C.\"}]","SCT-013-030 - Split-Core Current Transformer Technical Specification | PDF",1791809887]