[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-648355-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-648355-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","schick-elementary-building-plan-partition-type-schedule-notes-interior-partitions","SCHICK-ELEMENTARY-Building-Plan - Partition Type Schedule & Notes - Interior Partitions","","Partition type schedule and interior partition notes for the Schick Elementary building, specifying stud and wall assembly configurations using metal hat channels, metal studs, and gypsum board, with acoustic batt insulation. Includes details for wall infills and concrete masonry unit (CMU) wall thickness options, plus hour-rated fire separation references by test agency design numbers and locations. Provides general partition notes covering dimensional control, sealing requirements, furring termination heights, deflection tracks, backing for wall-hung items, bracing around above-ceiling interferences, and conventions for drawing interpretation and installation responsibilities.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/schick-elementary-building-plan-partition-type-schedule-notes-interior-partitions/648355/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/schick-elementary-building-plan-partition-type-schedule-notes-interior-partitions/648355.png","ImageObject",300,407,{"name":42,"@type":43},"pop out","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What wall and partition materials are specified for interior partitions?","Question",{"text":63,"@type":64},"The notes specify assemblies using metal hat channels and metal studs with 5/8\" gypsum board, with acoustic batt insulation fill. They also include infill guidance and CMU wall thickness options.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How are fire-rated separation requirements indicated in the document?",{"text":68,"@type":64},"Hourly fire ratings are indicated by test agency design numbers, with references to specific sheet locations for rated separation. The contractor must build partitions in strict compliance with the testing agency description for the design number.",{"name":70,"@type":61,"acceptedAnswer":71},"What key installation and dimensional requirements apply to all interior partitions?",{"text":72,"@type":64},"Interior partitions must extend tight to the floor or roof deck above (unless noted otherwise), be sealed to adjacent construction, maintain marked clear dimensions, and not vary more than 1/8\" in surface plane over 10 feet in any direction.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},648355,1792793213,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":30,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":111},962090760408,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","A  \nB  \nC  \nD  \nE  \nF  \nG  \nH  \nI  \nJ  \n1  \n\n| 2 |\n| --- |\n| 3 |\n| 4 |\n| 5 |\n| 6 |\n\n7  \n4/4/2022 9:29: 13 PM  \n\n| CLASSROOM |  |  |  |  |  |  |  |  |  | PARTITION TYPE SCHEDULE & NOTES INTERIOR PARTITIONS\u003Cbr>STUD PARTITIONS\u003Cbr>\u003Cbr>\u003Cbr>7/8\" MTL. HAT CHANNELS W/\u003Cbr>5/8\" GWB ONE SIDE.\u003Cbr>1 5/8\" MTL. STUDS W/ 5/8\" GWB ONE SIDE.\u003Cbr>FILL W/ ACOUS. BATT INSUL.\u003Cbr>2 1/2\" MTL. STUDS W/ 5/8\" GWB ONE SIDE.\u003Cbr>FILL W/ ACOUS. BATT INSUL.\u003Cbr>3 5/8\" MTL. STUDS W/ ONE LAYER OF 5/8\"\u003Cbr>GWB ON ONE SIDE, FILL W/ ACOUS. BATTINSUL.\u003Cbr>NOTE: (2) BACK-TO-BACK P3 WALLS: STC-50\u003Cbr>3 5/8\" MTL. STUDS W/ 5/8\" GWB\u003Cbr>E.S. , FILL W/ ACOUS. BATT INSUL.\u003Cbr>6\" MTL. STUDS W/ 5/8\" GWB E.S. , FILL W/ ACOUS. BATT INSUL.\u003Cbr>WALL INFILLS\u003Cbr>\u003Cbr>\u003Cbr>C. M. U. INFILL TO MATCH EXISTING WALL THICKNESS.\u003Cbr>MATCH EXISTING FIRE-RATING, WHERE APPLICABLE.\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>2 X MTL. STUDS WITH 5/8\" GWB E.S. INFILL TO\u003Cbr> _ \u003Cbr>MATCH EXISTING WALL THICKNESS; FILL WITHACOUS. BATT INSUL.\u003Cbr>CMU WALLS\u003Cbr>\u003Cbr>\u003Cbr>4\" C. M. U.\u003Cbr>6\" C. M. U.\u003Cbr>8\" C. M. U. - (1) HR. FIRE-RATED (U. L. \\#U905) \u003Cbr>SEE REFERENCE PLANS ON SHEETS A-0 .2 & A-0 .3 FOR RATED SEPARATION LOCATIONS\u003Cbr>8\" C. M. U. - (3) HR. FIRE-RATED (U. L. \\#U905) \u003Cbr>SEE REFERENCE PLANS ON SHEETS A-0 .2 & A-0 .3 FOR RATED SEPARATION LOCATIONS\u003Cbr>10\" C. M. U.\u003Cbr>12\" C. M. U.\u003Cbr>12\" C. M. U. - (4) HR. FIRE-RATED (U. L. \\#U904) \u003Cbr>SEE REFERENCE PLANS ON SHEETS A-0 .2 & A-0 .3\u003Cbr>FOR RATED SEPARATION LOCATIONS\u003Cbr>GENERAL PARTITION NOTES\u003Cbr>1. DIMENSIONS TAKEN TO FACE OF STUD OR FACE OF CMU, U. N.O.\u003Cbr>2.\u003Cbr>ALL NEW PARTITIONS SHALL BE PER PARTITION TYPE M8, U. N.O.\u003Cbr>3. PARTITIONS REQUIRING AN HOURLY RATING ARE INDICATED ON THE CODE ANALYSIS PLANS A0 .2, DESCRIBED IN THE PARTITION TYPES, THIS SHEET, AND ARE DEFINED BY A TESTING AGENCY DESIGN NUMBER. THE CONTRACTOR SHALL CONSTRUCT THESE  PARTITIONS IN STRICT COMPLIANCE WITH THE TESTING AGENT DESCRIPTION REFERRED TO BY THE DESIGN NUMBER. PARTITION TYPE DRAWINGS SHOULD BE USED FOR REFERENCE AND INFORMATION PURPOSES ONLY. SHOULD CONFLICTS OCCUR BETWEEN THE PARTITION TYPE AND THE TESTING AGENT DESCRIPTION, THE STRINGENT REQUIREMENT SHALL APPLY.\u003Cbr>4.\u003Cbr>REFER TO FINISH SCHEDULE FOR WALL FINISHES.\u003Cbr>5. ALL INTERIOR PARTITIONS ARE TO EXTEND TIGHT TO THE FLOOR OR ROOF DECK ABOVE, U.N.O. PARTITIONS MUST BE SEALED TO ADJACENT CONSTRUCTION.\u003Cbr>6.\u003Cbr>FURRING PARTITIONS AND G.W. B. TO TERMINATE A MIN. OF 6\" ABOVE FINISHED CEILING.\u003Cbr>7.\u003Cbr>PROVIDE DEFLECTION TRACKS ON TOP OF ALL METAL STUD WALLS THAT RUN CONTINUOUS FROM FLOOR TO UNDERSIDE OF\u003Cbr>STRUCTURE ABOVE.\u003Cbr>8. ALL DIMENSIONS MARKED \"CLEAR\" SHALL BE MAINTAINED.\u003Cbr>9.\u003Cbr>NO PARTITIONS SHALL VARY MORE THAN 1/8\" IN SURFACE PLANE IN 10 FEET IN ANY DIRECTION.\u003Cbr>10.\u003Cbr>WOOD BLOCKING FOR WALL HUNG SHELVING, MILLWORK, AND HARDWARE. BACKING SHALL SPAN AT LEAST 3 STUDS.\u003Cbr>11.\u003Cbr>PARTITION ASSEMBLIES AND BRACING SHALL BE INSTALLED AROUND ANY ABOVE-CEILING INTERFERENCES ENCOUNTERED SUCH AS\u003Cbr>DUCTS OR SPRINKLER LINES SO AS TO MAINTAIN THE INTEGRITY OF THE ASSEMBLY.\u003Cbr>12. ALL INTERIOR WALLS IN OCCUPIED AREAS AND PUBLIC ARES TO A MINIMUM OF 8'-0\" ABOVE FINISHED FLOOR MUST BE HIGH ABUSERESISTANT TYPE GYPSUM BOARD.\u003Cbr>13. ALL EXPOSED CMU WALLS SHALL HAVE A BULLNOSE EDGE. RADIUSED CEILING EDGE TRACK SHALL BE PROVIDED ACCORDINGLY\u003Cbr>14.\u003Cbr>SEAL FULL PERIMETER OF GWB/STUD WALLS WITH ACOUSTIC SEALANT.\u003Cbr>15.\u003Cbr>PROVIDE CONTROL JOINTS PER THE SPECIFICATION AT INTERIOR CMU WALLS FOR WALL LENGTHS GREATER THAN 20' . PROVIDE\u003Cbr>CONTROL JOINTS BETWEEN WALLS ON FLOOR SLABS AND WALLS ON FOOTINGS. REFER TO TYPICAL CONTROL JOINT DETAILS FOR\u003Cbr>ADDITIONAL CONTROL JOINT INFORMATION. | CONVENTIONS\u003Cbr>1.\u003Cbr>2.\u003Cbr>3.\u003Cbr>4.\u003Cbr>5.\u003Cbr>DETAILS ARE KEYED ONCE (ON THE PLANS OR ELEVATIONS WHEN THEY FIRST OCCUR) AND ARE TYPICAL FOR SIMILAR CONDITIONS THROUGH OUT U. N.O.\u003Cbr>TYPICAL OR \"TYP\" MEANS FOR ALL SIMILAR CONSTRUCTION, U. N.O.\u003Cbr>DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN ALWAYS.\u003Cbr>LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS.\u003Cbr>ALL VERTICAL DIMENSIONS SHOWN TO ","cbCaisVnSgv8m07C","https://ap.wps.com/l/cbCaisVnSgv8m07C","pdf",780157,"English","# Partition Type Schedule & Notes\n## Interior Partitions\n## Wall Infill and CMU Wall Options\n## General Partition Notes\n## Conventions and General Notes","[{\"question\":\"What wall and partition materials are specified for interior partitions?\",\"answer\":\"The notes specify assemblies using metal hat channels and metal studs with 5/8\\\" gypsum board, with acoustic batt insulation fill. They also include infill guidance and CMU wall thickness options.\"},{\"question\":\"How are fire-rated separation requirements indicated in the document?\",\"answer\":\"Hourly fire ratings are indicated by test agency design numbers, with references to specific sheet locations for rated separation. The contractor must build partitions in strict compliance with the testing agency description for the design number.\"},{\"question\":\"What key installation and dimensional requirements apply to all interior partitions?\",\"answer\":\"Interior partitions must extend tight to the floor or roof deck above (unless noted otherwise), be sealed to adjacent construction, maintain marked clear dimensions, and not vary more than 1/8\\\" in surface plane over 10 feet in any direction.\"}]","SCHICK-ELEMENTARY-Building-Plan - Partition Type Schedule & Notes - Interior Partitions | PDF"]