[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663324-105":59,"doc-detail-663324-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","sboa157a-vendor-item-drawings-ti-vendor-item-drawing-vid-requirements","SBOA157A - Vendor Item Drawings - TI Vendor Item Drawing (VID) Requirements","","Texas Instruments SBOA157A document explains Vendor Item Drawings (VIDs) and clarifies their administrative-control purpose versus specification drawings. It summarizes how the Defense Logistics Agency Logistics Information Service defines a VID, distinguishes VID scope for microcircuits, and specifies that the manufacturer-assigned part number is the item identification and PIN. It also outlines marking, product assurance responsibility, packaging for electrostatic discharge sensitive devices, and configuration control, then contrasts VIDs with non-equivalent MIL-SPEC/SMD/SLC documents and provides TI contact and legal notice.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/sboa157a-vendor-item-drawings-ti-vendor-item-drawing-vid-requirements/663324/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/sboa157a-vendor-item-drawings-ti-vendor-item-drawing-vid-requirements/663324.png","ImageObject",300,407,{"name":92,"@type":93},"Ivy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is a Vendor Item Drawing (VID) and what administrative role does it serve?","Question",{"text":111,"@type":112},"A VID is defined as a reference number category code tied to a drawing assigned by a design activity, used to delineate commercial or vendor-developed items meeting specified engineering and test requirements. It establishes an administrative control number for engineering documentation and is not used as part-identification numbering.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"How is the item identification (PIN) determined for items on a vendor item control drawing?",{"text":116,"@type":112},"The PIN for an item delineated on a vendor item control drawing is the part number assigned by the vendor.",{"name":118,"@type":109,"acceptedAnswer":119},"What key manufacturer requirements are stated for VID markings, assurance, packaging, and configuration control?",{"text":120,"@type":112},"The manufacturer must permanently and legibly mark parts with the manufacturer’s part number and include details such as manufacturer name (CAGE code or logo) and a Pin 1 identifier. The manufacturer is responsible for inspection and test requirements per internal documentation. Packaging, preservation, labeling, and marking must follow standard commercial practices for electrostatic discharge sensitive devices, and configuration control is based on the device manufacturer’s data book with the right to change without notice.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},663324,1793226600,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":52},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","Texas Instruments Incorporated  \nSBOA157A  \nPost Office Box 84 Sherman, Texas 75090 6412 Highway 75 South Sherman, Texas 75090  \n(903) 868-7111  \nVendor Item Drawings  \nThe Defense Logistic Agency Land and Maritime group (DSCC) is releasing new Vendor Item Drawings (VIDs) almost daily. While these documents have existed for some time there is still some confusion about exactly what is meant by a Vendor Item Drawing and the benefits of VIS system.  \nThe Defense Logistics Agency Logistics Information Service defines a VID as follows:  \nReference Number Category Code (RNCC) 7: Vendor Item Drawing Reference (formerly Specification Control Reference) . The number assigned by a design activity toa drawing that is not item identifying, but which delineates existing commercial or vendor developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s) . Includes only those drawings which meet the definition of Vendor Item Drawing in MIL-STD-100. Vendor item drawing references are administrative control numbers and shall not be used as part identification numbers.  \nMIL-STD-100 is a bit sketchy about the definition of a VID, also known as a Vendor Item Control Drawing, but in the case of microcircuits it is pretty specific about what isn’t a VID.  \n201.1 Standard microcircuit drawing (SMD) . […] Vendor item control drawings shall not be used to depict microcircuits (Federal Supply Class 5962) which comply with MIL-STD-883. Microcircuits compliant with MIL-STD-883 shall be depicted on an SMD.  \n406.10 Item identification and PIN. […] The PIN for an item delineated on a vendor item control drawing shall be the part number assigned by the vendor.  \nWithin the boilerplate of DSCC Vendor Item Drawings the requirements are further defined:  \nVendor Item Drawing Administrative Control Number-The manufacturer’s PIN is the item of identification. The vendor item drawing establishes an administrative control number for identifying the item on the engineering documentation:  \nMarking - Parts shall be permanently and legibly marked with the manufacturer’s part number as shown […] herein and as follows:  \nA. Manufacturer’s name, CAGE code or logo  \nB. Pin 1 identifier  \nC. ESDS identification (optional)  \nProduct assurance requirements - The manufacturer is responsible for performing all inspection and test requirements as indicated in their internal documentation  \nPackaging - Preservation, packaging, labeling, and marking shall be in accordance with the manufacturer’s standard commercial practices for electrostatic discharge sensitive devices.  \nConfiguration control-The data contained herein is based on the salient characteristics of the device manufacturer’s data book. The device manufacturer reserves the right to make changes without notice. This drawing will be modified as changes are provided.  \nIn general a VID is *NOT* a MIL-SPEC not is it the equivalent of a DSCC Standard Microcircuit Drawing (SMD) or a JAN Slash Sheet. VIDs exist to provide a procurement mechanism for enhanced commercial products such as TI’s Enhanced Products (EP) line. A VID provides a standardization format which precludes the need for most defense OEMs to generate specification control drawings (SCDs) or unique VIDs of their own and avoid the proliferation of multiple non-standard products.  \nFor critical requirements and those programs which require more that a enhanced commercialoff- the-shelf solutions, Texas Instruments offer a full line of QML Class V and QML Class Qmicrocircuits and the expertise to implement and qualify new designs or build-to-print products.  \nTexas Instruments is committed to providing the highest quality products to the HiRel, Defense, and Aerospace communities. Please feel free to contact the undersigned if additional information is required.  \nSincerely,  \nS. Richard Biddle  \nQuality and Reliability Assurance Engineering HiRel, Defense,","cbCaiiZu4X1N3vpW","https://ap.wps.com/l/cbCaiiZu4X1N3vpW","pdf",1646290,"English","# Vendor Item Drawing definition\n## Administrative control number and identification\n## VID vs SMD and other document types\n# Requirements within TI vendor item drawings\n## Marking\n## Product assurance requirements\n## Packaging and labeling\n## Configuration control\n# General notes and TI contact","[{\"question\":\"What is a Vendor Item Drawing (VID) and what administrative role does it serve?\",\"answer\":\"A VID is defined as a reference number category code tied to a drawing assigned by a design activity, used to delineate commercial or vendor-developed items meeting specified engineering and test requirements. It establishes an administrative control number for engineering documentation and is not used as part-identification numbering.\"},{\"question\":\"How is the item identification (PIN) determined for items on a vendor item control drawing?\",\"answer\":\"The PIN for an item delineated on a vendor item control drawing is the part number assigned by the vendor.\"},{\"question\":\"What key manufacturer requirements are stated for VID markings, assurance, packaging, and configuration control?\",\"answer\":\"The manufacturer must permanently and legibly mark parts with the manufacturer’s part number and include details such as manufacturer name (CAGE code or logo) and a Pin 1 identifier. The manufacturer is responsible for inspection and test requirements per internal documentation. Packaging, preservation, labeling, and marking must follow standard commercial practices for electrostatic discharge sensitive devices, and configuration control is based on the device manufacturer’s data book with the right to change without notice.\"}]","SBOA157A - Vendor Item Drawings - TI Vendor Item Drawing (VID) Requirements | PDF"]