[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649888-105":59,"doc-detail-649888-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","sauna-kit-rough-in-details","SAUNA Kit - Rough In Details","","Rough-in instructions for sauna material kits cover framing, strapping, insulation, and the sequence for electrical preparation. Walls are framed 16 in. on center and ceiling framing ensures cedar runs the shortest direction, with specified height guidance for typical sauna sizes. The guide lists included kit components such as foil vapor barrier, tongue-and-groove cedar, benches, heater with rocks, and doors, along with door rough-opening sizes and venting notes. Additional sections address heater wiring timing, bench and heater blocking, drainage guidance, and flooring tile considerations.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/sauna-kit-rough-in-details/649888/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/sauna-kit-rough-in-details/649888.png","ImageObject",300,407,{"name":92,"@type":93},"Fishy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-09","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What framing and ceiling height guidelines does the rough-in guide provide?","Question",{"text":112,"@type":113},"Use 2x4 spruce studs to frame walls and ceiling. Frame walls at 16 in. on center, and frame the ceiling to an inside height of 83-1/2\"; cedar should run the shortest direction. Typical sauna heights are around 7 ft or lower, with a minimum of about 75–78 in. depending on heater model.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"When should heater, control, and light wiring be completed?",{"text":117,"@type":113},"Electrical rough-in for the heater, control, and light should be done during this rough-in stage. If using an outside control, install the thermostat at this stage as well, then complete heater/light hook-up after the sauna is finished.",{"name":119,"@type":110,"acceptedAnswer":120},"What insulation and vapor barrier materials are specified?",{"text":121,"@type":113},"Fill wall and ceiling stud spaces with 3-1/2\" R-12 fiberglass insulation. Apply the foil vapour barrier over the inside edge face of studs over the insulation.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649888,1793049715,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":46,"preview_page_count":4},14431098389841,"https://eur-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","SAUNA Kit ROUGH IN DETAILS  \nThis rough-in guide is for our Sauna Material kits  \nFor more detail see “Sauna Material Kits” on website: [https://www.saunafin.com/resources](https://www.saunafin.com/resources)  \nYOU SUPPLY:  \nFRAMING:  \nUse 2 x 4 construction grade spruce studs to frame the walls and ceiling. Unless otherwise specified, for saunas up to 8' x 8', the walls are LINED HORIZONTALLY and FRAMED VERTICALLY. Frame the walls at 16\" on center. Frame or strap the ceiling to an inside height of 83-1/2\". Frame the ceiling so that the cedar will run the shortest direction. Provide extra blocking for bench supports and heater.  \nStandard kit height 831/2\".  \nMost Saunas are 7' height or lower. Minimum height is generally 75\" to 78\" depending on heater model.  \nMaximum sauna height should never be higher than 8'. If you really want higher, we strongly urge being as close to 7' as you are willing togo; i.e. 7'-4\" or 7'-6\".  \nSTRAPPING:  \nFor standard horizontal lining, strapping is not required.  \nIf lining vertically, strap (1 x 2 spf) over the foil to change direction. Can be used to create air space, but it is not necessary.  \nWIRING:  \nElectrical rough-in of heater, control and light should be done at this time. If using an outside control, the thermostat should be installed at this stage. (See heater specifications and control wiring diagrams for wire and breaker sizes.) Hook-up of the heater and light can be done after the sauna is completed.  \nINSULATION:  \nThe space between the studs in the walls and ceiling is filled with 3-1/2\", R-12 fiberglass insulation.  \nWE SUPPLY:  \n• Foil Vapour Barrier (apply over the inside edge face of studs over the insulation) .  \n• Tongue & groove cedar lining  \n• Benches  \n• Heater with rocks  \n• Heater Guard  \n• Doors  \n• Outlet cedar slide vent  \n• Cedar Floor (optional)  \nFrameless glass door is standard. Frameless glass door has jamb on four sides. And comes with detachable spacer for bottom which has channel for back up ventilation  \nWith included spacer blocking at bottom, rough opening is 27-1/2\" x 76-1/2\"  \nCedar framed door style Rough Opening 26\" x 76-1/2\"  \nROUGH OPENING: If unsure which door you want, we recommend going with the larger. You can always reduce and trim later.  \nFrameless Glass Door = 24\" x 72\". With bottom spacer, Rough Opening=271/2 x 761/2\".)  \nCedar Door Style. Size = 24\" x 74\". Standard Rough opening=26\" x 761/2\" .  \nLarger and custom doors available (i.e Tall Door=24\"x78\", Commercial Door=28\"x78\", Handicap Access=36\"x78\")  \nSAUNA DOORS SHOULD OPENS OUT.  \nOTHER CONSIDERATIONS  \nDRAINAGE  \nCommercial (public) saunas should have a drain in the center of the floor (sloped to the drain) to facilitate cleaning.  \nMost residential saunas have drains, but it is not essential. Water should only be used in moderation. (Our rule of thumb: If you are doing complete reno; i.e., breaking floors, new shower & bathroom, etc., we would suggest a sauna drain. If you are putting sauna in to an already finished area, it is likely not worth the cost to add a drain.  \nTILE  \nFor residential, tile is attractive and functional; however, it is also acceptable to leave cement. If sauna is on upper level with wood sub-floor, there should be a rubber membrane, cement scratch coat and tile (like shower floor).  \nIf floor is sloped to drain, mosaic tiles are best.  \nYou may add a tile baseboard up the wall 2-3\"  \nFile:Sauna Rough In text page  \nSPRUCE/PINE BENCH BLOCKING ( not included )  \n\n| 2x4 Bench and 1x4 Benches |  |  |  | Floating Benches |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| | |  | | |  |  |\n| 2x4 Bench Top blocking elevation: LK Plus, LK Premium,\u003Cbr>LK Knotty (with 2x4 bench tops)\u003Cbr>|  | 1x4 Bench Top blocking elevation: LK Knotty (with 1x4 bench tops)\u003Cbr>|  |  |  |  |\n| A = Top bench: From floor to top edge of blocking. B = Bottom bench: From floor to top edge of blocking. |  |  |  |  |  |  |\n\n\n|  | REINFORCING STUDS for HEATERS |  |  |\n| --- | --- | --- | --","cbCaisjfrixvyWR5","https://ap.wps.com/l/cbCaisjfrixvyWR5","pdf",3267938,"English","# Framing and Ceiling Setup\n## Strapping and Electrical Rough-In\n## Insulation and Included Kit Components\n# Door Rough Openings and Venting\n## Drainage and Flooring/Tiling","[{\"question\":\"What framing and ceiling height guidelines does the rough-in guide provide?\",\"answer\":\"Use 2x4 spruce studs to frame walls and ceiling. Frame walls at 16 in. on center, and frame the ceiling to an inside height of 83-1/2\\\"; cedar should run the shortest direction. Typical sauna heights are around 7 ft or lower, with a minimum of about 75–78 in. depending on heater model.\"},{\"question\":\"When should heater, control, and light wiring be completed?\",\"answer\":\"Electrical rough-in for the heater, control, and light should be done during this rough-in stage. If using an outside control, install the thermostat at this stage as well, then complete heater/light hook-up after the sauna is finished.\"},{\"question\":\"What insulation and vapor barrier materials are specified?\",\"answer\":\"Fill wall and ceiling stud spaces with 3-1/2\\\" R-12 fiberglass insulation. Apply the foil vapour barrier over the inside edge face of studs over the insulation.\"}]","SAUNA Kit - Rough In Details | PDF",1792810280]