[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-656531-105":59,"doc-detail-656531-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","saniflo-sanitop-installation-guide","Saniflo Sanitop Installation Guide","","Installation instructions for the Saniflo Sanitop macerating system designed for horizontal outlet spigots. Covers key safety warnings, inclusion and identification of accessories, required dimensions, domestic-use limitations, and how to connect the WC and additional sanitary appliances. Provides guidance for discharge pipe routing and performance considerations, including pipe size options, maximum lengths, fall requirements, air admittance valve use, insulation against freezing, and maintenance accessibility. Includes required electrical supply specifications and compliance notes.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/saniflo-sanitop-installation-guide/656531/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/saniflo-sanitop-installation-guide/656531.png","ImageObject",300,407,{"name":92,"@type":93},"Grenda","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the key installation safety warnings for the Sanitop unit?","Question",{"text":112,"@type":113},"The unit’s correct operation depends on proper installation and usage. Follow warnings about possible danger to personnel and electrical hazards, and note that failure to follow instructions may cause poor functioning.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should the Sanitop be connected to the WC?",{"text":117,"@type":113},"Connect the unit to a WC pan with a horizontal outlet spigot conforming to the specified standards. Apply silicon or liquid soap to the spigot, fit the collar, pull on the flexible sleeve, secure the metal hose clip, then fix the appliance to the floor using the supplied screws.",{"name":119,"@type":110,"acceptedAnswer":120},"What discharge pipework requirements must be met for reliable performance?",{"text":121,"@type":113},"Use correct pipe sizes (e.g., 22mm or 32mm options) and respect maximum lengths and minimum falls for horizontal runs. If a vertical lift is required, make it before the horizontal run, consider an air admittance valve where needed to avoid siphoning, ensure external pipework is lagged to prevent freezing, and connect properly to the soil stack.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},656531,1793110298,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},7971474921005,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","1. Description  \nThe macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to ISO 9001(2000) accredited by AFAQ. The correct operation of your unit depends on correct installation and usage.  \nPlease pay particular attention to the following:  \n Possible danger to personnel  \n Warning of possible electrical hazard  \n“ATTENTION” This is a general warning that failure to follow instructions could result in poor functioning of the unit.  \nThis equipment benefits from the latest technological innovations concerning soundproofing. To benefit fully from the advantages provided by this new generation of appliances, it is important to comply with the installation instructions in section 5.  \nPlease also see “10 golden rules” [for correct Saniflo installation on www.saniflo.co.uk](for correct Saniflo installation on www.saniflo.co.uk)  \n2. List of Accessories included  \n| \u003Cbr>A | | x1 |\n| --- | --- | --- |\n| Discharge elbow |  |  |\n\n\n| \u003Cbr>B | | x1\u003Cbr>x 50 |\n| --- | --- | --- |\n| Hose clip for discharge elbow |  |  |\n\n\n| \u003Cbr>\u003Cbr>C\u003Cbr>x1\u003Cbr>100mm 90 x 110 |\n| --- |\n| Hose clip for WC pan spigot |\n\n\n| \u003Cbr>E | | x1 |\n| --- | --- | --- |\n| Inlet Connector |  |  |\n\n\n| \u003Cbr>F | | x1 |\n| --- | --- | --- |\n| Herbie clip for connector |  |  |\n\n\n| | x1 |\n| --- | --- |\n| Herbie clip for connector |  |\n\n\n| \u003Cbr>H | | x1 |\n| --- | --- | --- |\n| \u003Cbr>Optional Euro 22-32mm reducer |  |  |\n\n\n| \u003Cbr>\u003Cbr>J\u003Cbr>x2 |\n| --- |\n| Floor mounting bracket |\n\n\n| \u003Cbr>K | |\n| --- | --- |\n| Discharge hose clip |  |\n\n\n| \u003Cbr>M | | x4 |\n| --- | --- | --- |\n| Rubber feet |  |  |\n\n\n| \u003Cbr>\u003Cbr>I\u003Cbr>x1 |\n| --- |\n| \u003Cbr>Discharge hose |\n\n3. Dimensions and overall measurements  \nThis pump/macerator has been designed to pump away the waste from a WC and the sanitary appliances in step 1.  \nThis unit is for domestic use only.  \nInstalled and used correctly, this unit will give consistent and reliable service.  \nYou can find the technical data in step 9.  \n4. Performance Curve & Height and Length of the discharge pipe  \nMetres  \n8  \n7  \n6  \n5  \n4  \n3  \n2  \n1  \n0  \nlitre/min  \n5m max  \n4m  \n3m  \n2m  \n1m  \n\n|  |\n| --- |\n|  |\n|  |\n\n0m 10m 20m 40m 60m 80m 90m  \nø 32  \nThe discharge pipe size for Sanitop can be 22mm or 32mm.  \n5. Installation  \nWARNING: The unit must be connected to WC pan with a horizontal outlet spigot conforming to EN33 or EN 37. The unit should be accessible for possible service.  \nIt is supplied with floor fixing lugs to prevent it from moving during use.  \nTo optimise the latest technical developments concerning soundproofing incorporated into this unit, it is important to:  \n• Position the WC pan so that it is not in contact with a partition or wall of the room.  \n• Place the WC pan on a perfectly level surface to ensure that the resilient mounts are fully efficient.  \n• Fix the discharge pipe correctly, with distances of not more than one metre between the fastenings.  \n6. WC Connection  \n• First, put some silicon or liquid soap on the WC spigot.  \n• Fit the collar supplied on the bowl outlet.  \n• Pull the flexible sleeve over the pan spigot.  \n• Position the metal hose clip (C) over the edge of the flexible sleeve and tighten with a screwdriver.  \n• Once the appliance has been positioned, fix it to the floor using the 2 screws (J) supplied.  \nWARNING! There should be no water dripping from the WC cistern or any other sanitary appliances. If there is, this will cause the unit to activate repeatedly as it pumps the water away.  \nThe Sanitop unit and all its connections should be easily accessible for possible maintenance / removal.  \n7. Connections of extra sanitary appliances  \n2  \nG  \nE   \nF  \nSee figs 1 and 2 for connections that may be required for sanitary appliances.  \n8. Connection of discharge pipework  \nInsert the discharge elbow (A) into the rubber discharge pipe which rises up through the lid, turn to the desired direction and secu","cbCaiouDcv2asBQs","https://ap.wps.com/l/cbCaiouDcv2asBQs","pdf",708466,"English","# Description\n# List of Accessories included\n# Dimensions and overall measurements\n# Performance Curve & Height and Length of the discharge pipe\n# Installation\n## WC Connection\n## Connections of extra sanitary appliances\n## Connection of discharge pipework\n## Technical advice for discharge pipework\n## Electrical connection","[{\"question\":\"What are the key installation safety warnings for the Sanitop unit?\",\"answer\":\"The unit’s correct operation depends on proper installation and usage. Follow warnings about possible danger to personnel and electrical hazards, and note that failure to follow instructions may cause poor functioning.\"},{\"question\":\"How should the Sanitop be connected to the WC?\",\"answer\":\"Connect the unit to a WC pan with a horizontal outlet spigot conforming to the specified standards. Apply silicon or liquid soap to the spigot, fit the collar, pull on the flexible sleeve, secure the metal hose clip, then fix the appliance to the floor using the supplied screws.\"},{\"question\":\"What discharge pipework requirements must be met for reliable performance?\",\"answer\":\"Use correct pipe sizes (e.g., 22mm or 32mm options) and respect maximum lengths and minimum falls for horizontal runs. If a vertical lift is required, make it before the horizontal run, consider an air admittance valve where needed to avoid siphoning, ensure external pipework is lagged to prevent freezing, and connect properly to the soil stack.\"}]","Saniflo Sanitop Installation Guide | PDF",1792969135,23]