[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-390891-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-390891-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","s1-s3-gravimetric-pm10-sampling-and-filter-conditioning-low-cost-sensor-platform-and-psl-sphere-chamber-experiments","S1-S3 Gravimetric PM1.0 sampling and filter conditioning - Low-cost sensor platform and PSL sphere chamber experiments","","Document sections S1–S3 describe methods to measure gravimetric PM1.0 and to build and validate a low-cost optical sensor platform. Filter-based sampling follows U.S. EPA procedures using controlled conditioning rooms for pre/post weighing, with field blanks subtracted to compute PM1.0 from flow rate and sampling duration. The sensor setup combines Sensirion SPS30 optical particle counting with an ADPD188BI blue-LED channel and an SHT31 humidity sensor, then performs dynamic calibration. Monodisperse PSL spheres are prepared through repeated centrifugation and nebulization, followed by chamber experiments and particle-size binning analysis using an optical particle counter.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/s1-s3-gravimetric-pm10-sampling-and-filter-conditioning-low-cost-sensor-platform-and-psl-sphere-chamber-experiments/390891/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/s1-s3-gravimetric-pm10-sampling-and-filter-conditioning-low-cost-sensor-platform-and-psl-sphere-chamber-experiments/390891.png","ImageObject",300,407,{"name":42,"@type":43},"Aria Callaghan","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-09","2026-09-25",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",23,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"How is gravimetric PM1.0 concentration calculated from filter weights?","Question",{"text":63,"@type":64},"Filters are conditioned in a controlled room, weighed before and after sampling, and field blanks from parallel blanks are used to correct the mass change. The concentration is computed from (post − pre − blank) and incorporates the volumetric flow rate and sampling duration.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What is the role of the SPS30 and ADPD188BI sensors in the platform?",{"text":68,"@type":64},"The SPS30 performs laser-based optical particle counting using light scattered by particles, reporting cumulative number concentrations and derived mass concentrations. The ADPD188BI optical module extends measurements using blue and infrared emitters and matched photodiodes, but the infrared channel is excluded due to noise dominance under the experimental conditions.",{"name":70,"@type":61,"acceptedAnswer":71},"Why are monodisperse PSL spheres prepared and used in chamber experiments?",{"text":72,"@type":64},"PSL spheres are prepared as monodisperse suspensions by centrifuging, washing to remove surfactant, redispersing, and nebulizing into the chamber. They are used to characterize the size-dependent response of the SPS30–ADPD188BI blue-LED measurement pair and to generate size-bin fraction results.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},390891,1790615659,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":107,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},962084926284,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","1 S1 Gravimetric PM1.0 sampling and filter conditioning  \n2 Gravimetric PM 1.0 mass concentrations were determined by filter-based sampling following U.S. EPA  \n3 procedures for fine PM2.5 conditioning and weighing (U.S Environmental Protection Agency, n.d.) . Filters  \n4 and the analytical balance were housed in a dedicated conditioning room that maintained controlled  \n5 temperature and relative humidity; all pre-and post-weighing was performed in this room to minimize  \n6 environmental drift. Before sampling, filters were equilibrated in the conditioning room for at least 24 h, 7 then weighed on a microbalance and recorded as 􀝉pre. After sampling, loaded filters were returned to the  \n8 same room, equilibrated for at least 24 h, and reweighed to obtain the post sampling mass, 􀝉post. Field  \n9 blanks from the conditioning room and test room were treated in parallel, and the mean blank mass change, 10 􀝉blank, was subtracted from each sample mass gain. The gravimetric PM 1.0 concentration for each sample  \n11 was calculated as  \n(􀝉post − 􀝉pre − 􀝉blank)  \n12 􀜥􀯉􀯆1.0 = 􀜳 × Δ􀝐 (􀜵1), 13 where 􀜳 is the volumetric flow rate (m³ min⁻¹) and Δ􀝐 is the sampling duration (min) . For the calibration  \n14 experiments, filters were collected over 10-minute intervals. Sensor data (SPS30 PM 1.0 and ADPD188BI  \n15 blue-LED channel signal) were averaged over the corresponding 10-minute periods to obtain paired  \n16 gravimetric-sensor points for the regression analysis.  \n17  \n18 S2 Low-cost sensor platform based on the Sensirion SPS30 and Analog Devices ADPD188BI  \n19 The SPS30 is a laser-based optical particle counter that detects light scattered by individual particles and  \n20 uses onboard algorithms to report cumulative particle number concentrations 􀜰􀜥0.5 , 􀜰􀜥1.0 , 􀜰􀜥2.5 , 􀜰􀜥4 , and  \n21 􀜰􀜥10 (cm⁻³), corresponding mass concentrations of PM1.0, PM2.5, PM4.0, and PM 10 (µg m⁻³), and a  \n22 characteristic particle size (nm). According to the manufacturer, the SPS30 reports mass concentrations  \n23 from 0 to 1000 µg m⁻³ with a resolution of 1 µg m⁻³. The stated precision for PM1.0 and PM2.5 of ± (5 µg  \n24 m⁻³ + 5 % of the measured value) µg m⁻³ and ±10 % of the measured value from 100 to 1000 µg m⁻³  \n25 (Datasheet SPS30 Particulate Matter Sensor for Air Quality Monitoring and Control) . TheADPD188BI  \n26 optical module was integrated to extend measurements to higher concentrations. The module includes blue  \n27 and infrared emitters, matched photodiodes, and onboard signal processing for measuring bulk light  \n28 scattering from particles above the chip. The ADPD188BI and an SHT31-DIS-B2.5KS temperature and  \n29 relative-humidity sensor were mounted inside a custom Accumold chamber that shared an air path with the  \n30 SPS30, ensuring that both optical sensors sampled the same aerosol (Analog Devices, 2020) . All sensors  \n31 were interfaced with a custom microcontroller board equipped with a real-time clock and microSD storage, 32 which logged synchronized SPS30 and ADPD188BI signals for subsequent dynamic calibration. The  \n33 ADPD188BI infrared channel was excluded because its signal was dominated by noise under the  \n34 experimental conditions.  \n35  \n36 S3 PSL sphere preparation and chamber experiments  \n37 Monodisperse PSL spheres were used to characterize the size-dependent response of the SPS30-  \n38 ADPD188BI blue-LED pair. PSL stock suspensions were centrifuged and washed five times to remove  \n39 residual surfactant. After each centrifugation step, the supernatant was discarded and replaced with 100 µL  \n40 of 99.5 % isopropyl alcohol, and the suspension was redispersed using a vibrating shaker (Agrawal et al., 41 2024; Tryner et al., 2020) . After the final wash, 1 mL of 99.5 % isopropyl alcohol was added to each  \n42 centrifuge tube. The suspension was redispersed and then transferred to the nebulizer. The spheres were  \n43 subsequently nebulized into the chamber.  \n44  \n45 Figure S1. Weighted Lasair particle-number bin fractions","cbCaiogieKFUa1D9","https://ap.wps.com/l/cbCaiogieKFUa1D9","pdf",864956,"English","# Method overview\n## S1 Gravimetric PM1.0 sampling and filter conditioning\n## S2 Low-cost sensor platform\n## S3 PSL sphere preparation and chamber experiments\n## Figures S1–S3 summaries","[{\"question\":\"How is gravimetric PM1.0 concentration calculated from filter weights?\",\"answer\":\"Filters are conditioned in a controlled room, weighed before and after sampling, and field blanks from parallel blanks are used to correct the mass change. The concentration is computed from (post − pre − blank) and incorporates the volumetric flow rate and sampling duration.\"},{\"question\":\"What is the role of the SPS30 and ADPD188BI sensors in the platform?\",\"answer\":\"The SPS30 performs laser-based optical particle counting using light scattered by particles, reporting cumulative number concentrations and derived mass concentrations. The ADPD188BI optical module extends measurements using blue and infrared emitters and matched photodiodes, but the infrared channel is excluded due to noise dominance under the experimental conditions.\"},{\"question\":\"Why are monodisperse PSL spheres prepared and used in chamber experiments?\",\"answer\":\"PSL spheres are prepared as monodisperse suspensions by centrifuging, washing to remove surfactant, redispersing, and nebulizing into the chamber. They are used to characterize the size-dependent response of the SPS30–ADPD188BI blue-LED measurement pair and to generate size-bin fraction results.\"}]","S1-S3 Gravimetric PM1.0 sampling and filter conditioning - Low-cost sensor platform and PSL sphere chamber experiments | PDF",1790341537,18,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/95fd28965722f93d4fd6462477f5a02e.webp",983,1272,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/1ab08d94929532ff0e5127586ea2082c.webp",982,1270,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/49d7af36e65b46fe4cbd3edbc470f51b.webp",981,1269,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/00e60b60248172d649167573bfc6dc74.webp",980,1268]