[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652312-105":59,"doc-detail-652312-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","rtag-air-cooled-helical-rotary-liquid-chillers-installation-operation-and-maintenance","RTAG Air-Cooled Helical Rotary Liquid Chillers - Installation, Operation, and Maintenance","","Installation, Operation, and Maintenance instructions for RTAG air-cooled helical rotary liquid chillers, covering 085-205 ton units (50 Hz) and identifying the publication code 572517440002 and revision Sep. 2017 (RTAG-SVX001A-EN). The manual emphasizes safety requirements for qualified personnel, outlines warnings, cautions, and notices, and stresses responsible refrigerant handling, certification, and compliance with regulations such as the Federal Clean Air Act (Section 608). It includes PPE guidance, high-pressure refrigerant recovery precautions, and electrical safety warnings, along with environmental concerns and equipment protection notices.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/rtag-air-cooled-helical-rotary-liquid-chillers-installation-operation-and-maintenance/652312/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/rtag-air-cooled-helical-rotary-liquid-chillers-installation-operation-and-maintenance/652312.png","ImageObject",300,407,{"name":92,"@type":93},"naya.afterrain","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to install and service RTAG air-cooled liquid chillers?","Question",{"text":112,"@type":113},"Only qualified personnel should install and service the equipment. Installation, starting up, and servicing can be hazardous and require specific knowledge and training.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What safety steps must be followed before opening the refrigerant system?",{"text":117,"@type":113},"Recover the refrigerant to relieve system pressure before opening. Use the refrigerant type from the unit nameplate and do not use non-approved refrigerants or additives.",{"name":119,"@type":110,"acceptedAnswer":120},"What does the manual require regarding refrigerant handling and environmental compliance?",{"text":121,"@type":113},"Technicians handling refrigerants must be certified, and procedures must follow requirements such as the Federal Clean Air Act (Section 608). The manual also advises knowing applicable laws and following responsible refrigerant practices.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652312,1793029749,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962094248482,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Installation, Operation, and Maintenance  \nRTAG Air-Cooled Helical Rotary Liquid Chillers  \nRTAG 085-205 ton units (50Hz)  \n572517440002  \n\n|  SAFETY WARNING |\n| --- |\n| Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. |\n\nSep. 2017 RTAG-SVX001A-EN  \nWarnings, Cautions and Notices  \nWarnings, Cautions and Notices Note that warnings, cautions and notices appear at appropriate intervals throughout this manual. Warnings are provide to alert installing contractors to potential hazards that could result in death or personal injury. Cautions are designed to alert personnel to hazardous situations that could result in personal injury, while notices indicate a situation that could result in equipment or property-damage-only accidents.  \nYour personal safety and the proper operation of this machine depend upon the strict observance of these precautions.  \nRead this manual thoroughly before operating or servicing this unit.  \nATTENTION: Warnings, Cautions and Notices appear at appropriate sections throughout this literature. Read these carefully:  \nD WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  \nD CAUTION Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices.  \nNOTICE: Indicates a situation that could result in equipment or property-damage  \nonly  \nImportant  \nEnvironmental Concerns!  \nScientific research has shown that certain man-made chemicals can affect the earth’s naturally occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs) . Not all refrigerants containing these compounds have the same potential impact to the environment. Trane advocates the responsible handling of all refrigerants-including industry replacements for CFCs such as HCFCs and HFCs.  \nResponsible Refrigerant Practices!  \nTrane believes that responsible refrigerant practices are important to the environment, our customers, and the air conditioning industry. All technicians who handle refrigerants must be certified. The Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and the equipment that is used in these service pro-  \ncedures. In addition, some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants. Know the applicable laws and follow them.  \n\n| D WARNING |\n| --- |\n| Contains Refrigerant!\u003Cbr>System contains oil and refrigerant under high pressure. Recover refrigerant to relieve pressure before opening the system. See unit nameplate for refrigerant type. Do not use non-approved refrigerants, refrigerant substitutes, or refrigerant additives.\u003Cbr>Failure to follow proper procedures or the use of non-approved refrigerants, refrigerant substitutes, or refrigerant additives could result in death or serious injury or equipment damage. |\n\n\n| D WARNING |\n| --- |\n| USING PERSONAL PROTECTIVE EQUIPMENT (PPE)!\u003Cbr>Dealing with refrigerant, Please always refer to the appropriate safety data sheets (MSDS) and the occupational safety and health (OSHA) guidelines, use proper breathing apparatus, pay attention to the eyes and body protection.Otherwise may cause serious inju","cbCaie04vcTpYaki","https://ap.wps.com/l/cbCaie04vcTpYaki","pdf",10987559,143,"English","# SAFETY WARNING\n# Warnings, Cautions and Notices\n# Literature History\n# Contents\n## Unit Model Number\n## CHHP Compressor Model Number\n## CHHW Compressor Model Number\n## Overview\n## Preface\n## Warranty\n## Unit Description\n## Inspection Checklist\n## Storage\n## Unit Identification-Nameplates\n## Unit Nameplate\n## General Data","[{\"question\":\"Who is allowed to install and service RTAG air-cooled liquid chillers?\",\"answer\":\"Only qualified personnel should install and service the equipment. Installation, starting up, and servicing can be hazardous and require specific knowledge and training.\"},{\"question\":\"What safety steps must be followed before opening the refrigerant system?\",\"answer\":\"Recover the refrigerant to relieve system pressure before opening. Use the refrigerant type from the unit nameplate and do not use non-approved refrigerants or additives.\"},{\"question\":\"What does the manual require regarding refrigerant handling and environmental compliance?\",\"answer\":\"Technicians handling refrigerants must be certified, and procedures must follow requirements such as the Federal Clean Air Act (Section 608). The manual also advises knowing applicable laws and following responsible refrigerant practices.\"}]","RTAG Air-Cooled Helical Rotary Liquid Chillers - Installation, Operation, and Maintenance | PDF",1792879536,360]