[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-656551-105":59,"doc-detail-656551-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","riser-diagram-wiring-specifications-and-connection-requirements-for-5-station-area-of-refuge-systems","Riser Diagram - Wiring Specifications and Connection Requirements for 5-Station Area of Refuge Systems","","Riser diagram wiring and connection specifications for a 5-station Area of Refuge Systems layout. Defines maximum cable distance ranges between the Command Unit and each call station by wire gauge (18, 20, 22, and 24 AWG) and recommends twisted, shielded pairs with shielding earthed at the Command Unit end. Includes important survivability and firestop engineering guidance by jurisdiction, outlines cellular gateway telephone connectivity, and lists analog phone line requirements including talk battery and current and feature-free line constraints.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/riser-diagram-wiring-specifications-and-connection-requirements-for-5-station-area-of-refuge-systems/656551/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/riser-diagram-wiring-specifications-and-connection-requirements-for-5-station-area-of-refuge-systems/656551.png","ImageObject",300,407,{"name":92,"@type":93},"OmBimo","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-31","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How far can the call station be from the Command Unit for each wire gauge?","Question",{"text":112,"@type":113},"Supported distance ranges are 2,501–3,500 ft for 18 AWG, 1,501–2,500 ft for 20 AWG, 1,001–1,500 ft for 22 AWG, and 0–1,000 ft for 24 AWG.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What wiring type is recommended and how should the shield be handled?",{"text":117,"@type":113},"Twisted, shielded pairs are recommended, with the shield connected to earth ground at the Command Unit end.",{"name":119,"@type":110,"acceptedAnswer":120},"What analog phone line requirements must be met for the cellular gateway connection?",{"text":121,"@type":113},"Use a minimum 24V talk battery and 20 mA off-hook loop current, provide either a CPC disconnect pulse or 30 seconds of silence after hang-up, and ensure the analog line/extension is feature free (no hook flash, call waiting, auto-redial, voicemail, etc.).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},656551,1792969212,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962090893581,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","| Riser Diagram for 5-Station Area of Refuge Systems\u003Cbr>`\u003Cbr>Wiring Specifications for Each Call Station:\u003Cbr>(A) Maximum cable length will vary with wire gauge.\u003Cbr>\u003Cbr>(1) With 18 AWG wire, the supported distance range between Command Unit and Call Station is 2,501-3,500 ft.\u003Cbr>(2) With 20 AWG wire, the supported distance range between Command Unit and Call Station is 1,501-2,500 ft.\u003Cbr>(3) With 22 AWG wire, the supported distance range between Command Unit and Call Station is 1,001-1,500 ft.\u003Cbr>(4) With 24 AWG wire, the supported distance range between Command Unit and Call Station is 0-1,000 ft.\u003Cbr>(B) Twisted, shielded pairs are recommended with the shield connected to earth ground atthe Command Unit end.\u003Cbr>Sub-Command Unit \\#1\u003Cbr>(Model HON-AOR-SCU-1)\u003Cbr>\u003Cbr>Command Unit\u003Cbr>(Model HON-AOR-5*)\u003Cbr>FLR 1\u003Cbr>IMPORTANT NOTE:\u003Cbr>(A) Survivability requirements and regulations may vary depending on the local jurisdiction. Please contact your Authority Having Jurisdiction (AHJ) for further details.\u003Cbr>(B) Since fire-rated system requirements can vary from jurisdiction to jurisdiction, please approach a third-party firestop company for an \"engineering judgment\" or“firestop EJ”.\u003Cbr>(C) Installation of components of the system into a fire-rated area or room may be required depending on the requirements of the jurisdiction.\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Telco/PSTN Connection through Cellular Gateway (Model HON-AOR-CGW-*)\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Analog Phone Line/Extension Requirements:\u003Cbr>(A) Minimum of 24V talk battery and 20 mA off-hook loop current\u003Cbr>(B) Analog phone line/extension should provide either a CPC (Calling Party Control) disconnect pulse (voltage drop at end of call) or 30-seconds of silence after hang-up (nore-order or howler feature) .\u003Cbr>(C) There must be no special features (e. g., hook flash, call waiting, auto-redial when busy, voicemail, etc.) . The analog phone line/extension must be feature free.\u003Cbr>\u003Cbr>Primary AC 102-132VAC, 50/60Hz\u003Cbr>Sub-Command Unit \\#2\u003Cbr>(Model HON-AOR-SCU-1)\u003Cbr>\u003Cbr>External Class 2 Power Supply\u003Cbr>Primary AC Input: 102-132VAC, 50/60Hz, 3.5A\u003Cbr>DC Output:\u003Cbr>24VDC, 2.5A\u003Cbr>(Model HON-AOR-PSU-5-10)\u003Cbr>LOC 5\u003Cbr>\u003Cbr>Call Station\u003Cbr>(Model HON-AOR-CSE-*) LOC 4\u003Cbr>\u003Cbr>Call Station (Model HON-AOR-CSE-*) LOC 3\u003Cbr>\u003Cbr>Call Station (Model HON-AOR-CSE-*) LOC 2\u003Cbr>\u003Cbr>Call Station (Model HON-AOR-CSE-*) LOC 1\u003Cbr>\u003Cbr>Call Station (Model HON-AOR-CSE-*) |  |  |\n| --- | --- | --- |\n| Talk-A-Phone, LLC\u003Cbr>7530 N. Natchez Ave.\u003Cbr>Niles, IL 60714 773-539-1100 [info@talkaphone.com](info@talkaphone.com)[ ](info@talkaphone.com)[www.honeywellareaofrefuge.com](www.honeywellareaofrefuge.com) | © 2024 Talk-A-Phone, LLC. All rights reserved. Specifications subject to change without notice.\u003Cbr>The Honeywell trademark is used under license from Honeywell International Inc.\u003Cbr>Honeywell International Inc. makes no representation or warranties with respect to these products. These products are manufactured by Talk-A-Phone, LLC, Niles, IL 60714, USA.\u003Cbr>RevA | 04/03/2024 | |","cbCaidaivXe5ipht","https://ap.wps.com/l/cbCaidaivXe5ipht","pdf",178578,"English","# Wiring Specifications for Each Call Station\n## Cable Distance by Wire Gauge\n## Survivability and Firestop Installation Notes\n## Telco/PSTN Connection through Cellular Gateway\n## Analog Phone Line/Extension Requirements","[{\"question\":\"How far can the call station be from the Command Unit for each wire gauge?\",\"answer\":\"Supported distance ranges are 2,501–3,500 ft for 18 AWG, 1,501–2,500 ft for 20 AWG, 1,001–1,500 ft for 22 AWG, and 0–1,000 ft for 24 AWG.\"},{\"question\":\"What wiring type is recommended and how should the shield be handled?\",\"answer\":\"Twisted, shielded pairs are recommended, with the shield connected to earth ground at the Command Unit end.\"},{\"question\":\"What analog phone line requirements must be met for the cellular gateway connection?\",\"answer\":\"Use a minimum 24V talk battery and 20 mA off-hook loop current, provide either a CPC disconnect pulse or 30 seconds of silence after hang-up, and ensure the analog line/extension is feature free (no hook flash, call waiting, auto-redial, voicemail, etc.).\"}]","Riser Diagram - Wiring Specifications and Connection Requirements for 5-Station Area of Refuge Systems | PDF"]