[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641000-105":59,"doc-detail-641000-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","rhs32-installation-and-operation-manual","RHS32 - Installation and Operation Manual","","Model RHS32 installation and operation manual outlining product registration and warranty extension, service contact instructions, and system certification claims. Covers safety and preparation requirements including minimum inlet water flow and pressure limits, electrical specifications, and conditions affecting regeneration performance. Includes a detailed table of contents and technical performance information such as demand initiated regeneration, rated softening capacity, efficiency measurement basis, water usage during regeneration, flow rates, pressure drop, and temperature constraints. Guidance also references resin quantity and limitations for capacity under varying water conditions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/rhs32-installation-and-operation-manual/641000/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/rhs32-installation-and-operation-manual/641000.png","ImageObject",300,407,{"name":92,"@type":93},"cksankcs","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-13","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What information should be ready when contacting support for the water softener?","Question",{"text":112,"@type":113},"Have the model and serial number available. The serial number is found on the rating decal inside the salt lid.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What demand feature does this system use and what is its purpose?",{"text":117,"@type":113},"The system uses a demand initiated regeneration (D.I.R.) feature designed to minimize the amount of regenerant brine and water used during operation.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the minimum inlet water flow and pressure limits before installation?",{"text":121,"@type":113},"The water softener requires a minimum inlet water flow of 3 gallons per minute, and a maximum allowable inlet water pressure of 125 psi.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641000,1792712427,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144,"preview_page_count":4},3985747882755,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Model RHS32  \nHow to install, operate and maintain your Demand Controlled Water Softener  \nPRODUCT REGISTRATION  \nAND WARRANTY EXTENSION  \nPlease register your product on [rheemwatertreatment.com](rheemwatertreatment.com)  \nSee warranty page for extended warranty details.  \nIf you have any questions or concerns when installing, operating or maintaining your water softener, call our toll free number:  \n1-800-754-7027 [or visit](or visit www.rheemwatertreatment.com)[ www.rheemwatertreatment.com](or visit www.rheemwatertreatment.com)  \nWhen you call, please be prepared to provide the model and serial number of your product, found on the rating decal inside the salt lid.  \nSystem tested and certified by NSF International  \nagainst NSF/ANSI Standard 44 for hardness reduction, efficiency and the reduction of barium and radium 226/228 , and certified to NSF/ANSI/CAN Standard 372.  \nInstallation and Operation Manual  \nManufactured and warranted by Water Channel Partners  \n1890 Woodlane Drive  \nWoodbury, MN 55125 7386465 ( Rev. D 5/ 14/21)  \nTABLE OF CONTENTS  \nPage  \nSpecifications & Performance Claims ............................................................ 3  \nBefore You Start ............................................................................ 4  \nInspect Shipment ............................................................................ 5  \nWater Conditioning Information ................................................................. 5  \nInstallation Requirements .................................................................... 6-7  \nInstallation Instructions ..................................................................... 8-11  \nProgramming the Water Softener ........................................................... 12-14  \nCustomizing Features .................................................................... 15-16  \nRoutine Maintenance ..................................................................... 17-18  \nTroubleshooting ......................................................................... 19-2 1  \nExploded View & Parts List ................................................................ 22-25  \nWarranty ................................................................................. 26  \nDimensions  \nTOP VIEW  \nSIDE VIEW FRONT VIEW FIG. 1  \nSpecifications & Performance Claims  \nThis model is efficiency rated. The efficiency rating is valid only at the minimum salt dose. This system has a demand initiated regeneration ( D. I. R. ) feature that complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in their operation.  \nThis water softener has a rated softener efficiency of not less than 3 ,350 grains of total hardness exchange per pound of salt (based on sodium chloride) and shall not deliver more salt than its listed rating or be operated at a sustained maximum service flow rate greater than its listed rating. This system has been proven to deliver soft water for at least ten continuous minutes at the rated service flow rate. The rated salt efficiency is measured by laboratory tests described in NSF/ANSI Standard 44. These tests represent the maximum possible efficiency that the system can achieve. Operational efficiency is the actual efficiency after the system has been installed. It is typically less than the rated efficiency, due to individual application factors including water hardness, water usage, and other contaminants that reduce a softener's capacity.  \n\n|  | Model RHS32 |\n| --- | --- |\n| Model Code | rH32 |\n| Rated Softening Capacity (Grains @ Salt Dose) | 13 ,000 @ 2.6 lbs.\u003Cbr>27 ,600 @ 8.3 lbs.\u003Cbr>33 ,000 @ 14.1 lbs. |\n| Rated Efficiency (Grains/ Pound of Salt @ Minimum Salt Dose) | 4 ,940 @ 2.6 lbs. |\n| Water Used During Regeneration @ Minimum Salt Dose | 1.9 gallons / 1 ,000 grains |\n| Total Water Used Per Regeneration @ Maximum Salt Dose | 33.3 gallons |\n| Rated Service Flow Rate | 7.9 gpm |\n| Amount of High C","cbCaieG5nxFtM7zF","https://ap.wps.com/l/cbCaieG5nxFtM7zF","pdf",1683552,26,"English","# Specifications & Performance Claims\n## Before You Start\n## Inspect Shipment\n## Water Conditioning Information\n## Installation Requirements\n## Installation Instructions\n## Programming the Water Softener\n## Customizing Features\n## Routine Maintenance\n## Troubleshooting\n## Exploded View & Parts List\n## Warranty","[{\"question\":\"What information should be ready when contacting support for the water softener?\",\"answer\":\"Have the model and serial number available. The serial number is found on the rating decal inside the salt lid.\"},{\"question\":\"What demand feature does this system use and what is its purpose?\",\"answer\":\"The system uses a demand initiated regeneration (D.I.R.) feature designed to minimize the amount of regenerant brine and water used during operation.\"},{\"question\":\"What are the minimum inlet water flow and pressure limits before installation?\",\"answer\":\"The water softener requires a minimum inlet water flow of 3 gallons per minute, and a maximum allowable inlet water pressure of 125 psi.\"}]","RHS32 - Installation and Operation Manual | PDF",66]