[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-350899-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-350899-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","retrospective-evaluation-of-high-dose-rate-brachytherapy-multicriteria-planning-using-physical-dose-versus-radiobiological-criteria-for-prostate-cancer","Retrospective evaluation of high-dose-rate brachytherapy multicriteria planning using physical dose versus radiobiological criteria for prostate cancer","","Radiobiological indices can inform treatment efficacy beyond traditional physical dose metrics and enable comparison across radiotherapy plans. This study integrates radiobiological indices with standard physical dose criteria to improve HDR brachytherapy plan evaluation within a multicriteria optimization (MCO) framework. Using the GPU-based gMCO algorithm, 2000 Pareto-optimal plans were optimized for a 15 Gy HDR boost. Tumour control probability (TCP), normal tissue complication probability (NTCP), and uncomplicated tumour control probability (UTCP) were computed for each plan. Maximizing UTCP alone reduced target coverage, while maximizing target coverage under institutional constraints impaired UTCP. Prioritizing institutional criteria first, then maximizing UTCP, balanced tumour control and normal tissue safety. Combining UTCP with standard dose metrics in MCO improves optimization, whereas relying on standard TCP/NTCP models with recommended parameters can yield clinically unacceptable plans.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/retrospective-evaluation-of-high-dose-rate-brachytherapy-multicriteria-planning-using-physical-dose-versus-radiobiological-criteria-for-prostate-cancer/350899/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/retrospective-evaluation-of-high-dose-rate-brachytherapy-multicriteria-planning-using-physical-dose-versus-radiobiological-criteria-for-prostate-cancer/350899.png","ImageObject",300,407,{"name":42,"@type":43},"Patrick","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-06","2026-09-22",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the main goal of this retrospective evaluation study?","Question",{"text":63,"@type":64},"To integrate radiobiological indices with standard physical dose criteria to improve evaluation and selection of HDR brachytherapy plans for prostate cancer within a multicriteria optimization framework.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were the HDR brachytherapy treatment plans generated and assessed?",{"text":68,"@type":64},"Using the GPU-based gMCO algorithm, 2000 Pareto-optimal plans were optimized for a 15 Gy HDR boost. For each plan, TCP, NTCP, and UTCP were calculated to quantify tumour control and normal tissue risk.",{"name":70,"@type":61,"acceptedAnswer":71},"Why does maximizing UTCP alone lead to insufficient target coverage?",{"text":72,"@type":64},"The study shows that optimizing for UTCP alone can produce plans with inadequate target coverage (target V100 below 90%) compared with clinical guidelines.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},350899,1791154352,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},549758146520,"https://ap-avatar.wpscdn.com/avatar/80002397d8c0411e94?_k=1775819394049821470","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nRetrospective evaluation of high-dose-rate brachytherapy multicriteria planning using physical dose versus radiobiological criteria for prostate cancer  \nCharles Iorio-Duval1,3,4,5, Cédric Bélanger1,2,4,5, Éric Vigneault4 & Luc Beaulieu1,2,4􀀍  \nRadiobiological indices can provide insights into treatment efficacy beyond traditional physical dose metrics and potentially facilitate the comparison between various radiotherapy plans. This study investigates the integration of radiobiological indices with standard physical dose criteria to improve high-dose-rate (HDR) brachytherapy plan evaluation and selection process for the treatment of prostate cancers in a multicriteria optimization (MCO) framework. This is accomplished within the framework of a graphics processing unit-based multicriteria optimization algorithm, gMCO. 2000 Pareto-optimal plans for 200 patients were optimized for a 15 Gy HDR brachytherapy boost after external beam radiation therapy (44 Gy in 22 fractions). Tumour control probability (TCP), normal tissue complication probability (NTCP), and uncomplicated tumour control probability (UTCP) were calculated for each plan. Maximizing UTCP alone resulted in insufficient target coverage (target V100 \u003C 90%) according to clinical guidelines. Conversely, maximizing target coverage while meeting institutional criteria compromised UTCP significantly (reduction of about 0.09). Selecting plans that met all institutional criteria first, then maximizing UTCP, achieved a balanced compromise between tumour control and normal tissue safety. While combining UTCP and standard dose metrics based on dose-volume histogram (i.e., absorbed dose or physical dose constraints) with MCO can enhance brachytherapy plan optimization, exclusive reliance on standard TCP and NTCP models, using recommended parameters, yields clinically unacceptable plans.  \nKeywords High-dose rate brachytherapy, Radiobiology, TCP, NTCP, UTCP, Prostate Cancer  \nInstitutional protocols used for radiotherapy treatment planning have the main objective of killing tumouroustissues while preserving as much normal tissue as possible. Those protocols are based on dosimetric criteria meant to quantify the amount of energy absorbed by tissues (i.e., absorbed dose or physical dose) . However, the effect of those treatments on patients is affected not only by absorbed dose but also by the context surrounding the treatment (e.g., treatment time, number of fractions, dose-rate, etc.) . Two treatments issuing the same physical dose to the patient will have a different impact depending on how the dose is delivered. In that regard, radiobiological indices could be used as optimization criteria to improve current radiotherapy planning algorithms and open new perspectives for decision-making in the clinic. Radiobiological indices consider important radiobiological responses such as reparation and repopulation of cancerous and normal tissue in the treatment efficacy as well as its fractionation effect1–3. If well modelled, radiobiological indices could be used as a measurement of the compromise between tumour control and adverse effects to organs at risk (OARs)4.  \nThroughout the years, many radiobiological models have been developed using various statistical techniques5,6. Biological effective dose (BED)-based models, generally derived from the linear quadratic (LQ) formalism, were developed to be used as comparative tools between different treatments3,7. BED can also be  \n1Département de Physique, de génie physique et d’optique et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada. 2Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec – Université Laval, Québec, Canada. 3Département de Physique, Université de Sherbrooke, Sherbrooke, Canada. 4Axe Oncologie, Centre de recherche CHU de Québec-Université Laval, CHU de Québec, Québec, Canada","cbCaisS6tHKutFtS","https://ap.wps.com/l/cbCaisS6tHKutFtS","pdf",2416318,11,"English","# Overview\n## Rationale and objective\n## Methods\n## Results and plan selection strategy","[{\"question\":\"What is the main goal of this retrospective evaluation study?\",\"answer\":\"To integrate radiobiological indices with standard physical dose criteria to improve evaluation and selection of HDR brachytherapy plans for prostate cancer within a multicriteria optimization framework.\"},{\"question\":\"How were the HDR brachytherapy treatment plans generated and assessed?\",\"answer\":\"Using the GPU-based gMCO algorithm, 2000 Pareto-optimal plans were optimized for a 15 Gy HDR boost. For each plan, TCP, NTCP, and UTCP were calculated to quantify tumour control and normal tissue risk.\"},{\"question\":\"Why does maximizing UTCP alone lead to insufficient target coverage?\",\"answer\":\"The study shows that optimizing for UTCP alone can produce plans with inadequate target coverage (target V100 below 90%) compared with clinical guidelines.\"}]","Retrospective evaluation of high-dose-rate brachytherapy multicriteria planning using physical dose versus radiobiological criteria for prostate cancer | PDF",1790091719,28,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/10bc74ecd0a512be9574c12257ea6db1.webp",983,1291,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/70f52f07abfb805646cde5a3b34b0f06.webp",982,1290,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/fbcf83c572467b0a66d7110349ce6db3.webp",981,1289,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/78add7476620b1642fd05eea0a83cec1.webp",980,1287]