[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649355-105":59,"doc-detail-649355-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","residential-deck-drawings-permit-requirements-and-sample-drawings","Residential Deck Drawings - Permit Requirements and Sample Drawings","","Residential Deck Drawings outline submittal requirements for constructing a deck above grade in St. Bernard, Ohio. The document specifies that permit approval is required and lists the code-based items that must appear on submitted drawings, aligned with the 2019 Residential Code of Ohio. It provides general notes covering lumber treatment, metal fasteners, design loads, footing specifications, guard and stair requirements, and example plan sheets for use in completing deck plan sets.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/residential-deck-drawings-permit-requirements-and-sample-drawings/649355/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/residential-deck-drawings-permit-requirements-and-sample-drawings/649355.png","ImageObject",300,407,{"name":92,"@type":93},"DoDO","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-31","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Is a permit required for a residential deck in St. Bernard, Ohio?","Question",{"text":112,"@type":113},"Yes. A permit is required for any deck that is above grade level, including decks where the bottom of the structure is on the ground.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which code-related items must be included on the permit drawings?",{"text":117,"@type":113},"The drawings must include a set of required items that relate to building and zoning compliance and align with the 2019 Residential Code of Ohio.",{"name":119,"@type":110,"acceptedAnswer":120},"What general construction requirements are specified for the deck?",{"text":121,"@type":113},"The plans specify pressure-treated lumber, hot-dipped galvanized metal fasteners and hangers, defined design loads, cast-in-place concrete footings with minimum compressive strength, and guard and stair rules including load and spacing constraints.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649355,1792799547,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":52},962093270745,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| Village of St Bernard  \u003Cbr>Department of Buildings &Plannins  \u003Cbr>110 Washington Avenue  \u003Cbr>St.Bernard,Ohio 45217  \u003Cbr>(513)-242-7770 Fax (513)-641-1840  \u003Cbr>http://www.cityofstbernard.or  \u003Cbr>Residential Deck Drawings  \u003Cbr>A permit is requlred for any deck that is above grade level.This indudes decks thathave the bottom of the structure on he gTound.PLans should  \u003Cbr>include three coples of deck construction drawings and lot plans with the deck shown to scaleand the distance to property lines  \u003Cbr>When apphying fora permlt to construct a deck,there areafew item sthat must be submltted fo buildingand zoning complance.Thece items need  \u003Cbr>to appear on the drawings submitted with theapplication form for a permit They are related to reguirementsin the 2019 Residential Code of Ohio.A  \u003Cbr>coDy of the code Is available for reference at https//www.com.ohlo.gov/dico/BBS Click \"Codes\"  \u003Cbr>The information and details shown on the folllowing sheets can be used as part of your permit plans for your deck.They are avaibable asauideto  \u003Cbr>help you with the detalling and they can be used parrtially orin full.For example,ifyou have Framing Plans already prepared,then any of the othe  \u003Cbr>Information such as the Stair Section and one of the Ledger Board Details,can be printed and submitted along with the Frmlng Plans to complete  \u003Cbr>your set of drawings.  \u003Cbr>Pleecall our offlce lfyou have any questlons orlf you need asskstance using the drawings.Our drawines are one example and arenot theonh  \u003Cbr>wayto comphy fordeck pemlts.   |  |\n| --- | --- |\n| General Notes  \u003Cbr>10.Lve Load Defection:Jolst &Beams-L360  \u003Cbr>1.Al lumber shall be pressure treated No.2Southem Pineor better  \u003Cbr>2.Almetalasteners &hangers shall be hot-dipped galvanked  \u003Cbr>Guards-V240  \u003Cbr>11.Design Loads;Floor Lve Load-40lbs/sf (min.  \u003Cbr>steel,stainless steel.G185 gakanked or otherwice compatible  \u003Cbr>wlth the wood treatment All bolits shall be 1/2\"diameter minimum.  \u003Cbr>WindSpeed-90 mph (Vult 115 mph)  \u003Cbr>3.Al beams and top rll splices shal occurata post orothenwise  \u003Cbr>Soll Bearing Pressure-1500 Ibs./sf  \u003Cbr>12.Guards shallbe designed fora 200 b.concentrated load placed along  \u003Cbr>on adequate bearing.  \u003Cbr>4.All footings shall be cast-in-place concrete with amin.2500 ps  \u003Cbr>the top of the rall in any directlon,at amy point.  \u003Cbr>13.This deck/porch isnot designed for hot-tub or spa loading.  \u003Cbr>compressive strength  \u003Cbr>14.Alexteriorstairs&associated kandlngs shallbeilluminated  \u003Cbr>5.Guards are required at allareas where the deck/Dorchfoor is  \u003Cbr>15.Post size is based on the helght of the deck floor above finished  \u003Cbr>greater than 30\"above grade for a distance of3feet measured from  \u003Cbr>edge of deck.  \u003Cbr>grade (at the hlghest point):  \u003Cbr>0'to 8'high 4x4.4x6.6x6  \u003Cbr>6.Requlred guards shal be 36”tal (min.land be constructed such  \u003Cbr>that a4”diameter object will not pass throue九  \u003Cbr>8'and up:6x6  \u003Cbr>16.The actual feld construction shell mstch the aoproved plans.Al feld  \u003Cbr>7.Guard post spacing shall not exceed 6ttoncenter.  \u003Cbr>8.Guards and handrailsare required at all stairs that are greater  \u003Cbr>chanresand/ordeviations requlre an Endneering Chanre Pproval  \u003Cbr>than 30\"above grade.  \u003Cbr>一  \u003Cbr>9.The deck/porch floor shall be within 30”of the of the door threshold   |  |\n| Front Elevation View  \u003Cbr>4x4 guordrail support post(typ.)  \u003Cbr>DO NOT NOTCH  \u003Cbr>2x4 top roil (typ.)  \u003Cbr>4°diometer objact sholl not  \u003Cbr>poss through(typ.)  \u003Cbr>6x6 diogonal bracing reg'd t ol  \u003Cbr>posts when deck/porch floor  \u003Cbr>excesds 10'obove any odjocent  \u003Cbr>grade.  \u003Cbr>X°diometer bolts ot  \u003Cbr>diogonal brace(typ.)  \u003Cbr>Post base  \u003Cbr>Posts to be morked  \u003Cbr>2'-0°  \u003Cbr>finished grode  \u003Cbr>connector  \u003Cbr>Ground Contact\"  \u003Cbr>:4  \u003Cbr>mn.  \u003Cbr>Fill in the footing diameter in  \u003Cbr>min.  \u003Cbr>inches or show on plan°.  \u003Cbr>Poat on top of buried  \u003Cbr>Choose a footing option:[]  \u003Cbr>Post ottoched to  \u003Cbr>[]  \u003Cbr>top of concrete  \u003Cbr>concrete footing  \u003Cbr>footing  \u003Cbr>a.The tyoicol fooli","cbCaivdq19JBoH08","https://ap.wps.com/l/cbCaivdq19JBoH08","pdf",376173,"English","# General Notes\n## Permit and Submittal Requirements\n## Structural and Load Requirements\n# Front Elevation View\n## Guardrail and Post Details\n# Foundation & Framing Plan\n## Guardrail Support and Ledger Connections\n## Joist and Span Selection\n# Framing Table\n## Floor Joist and Beam Maximum Spans","[{\"question\":\"Is a permit required for a residential deck in St. Bernard, Ohio?\",\"answer\":\"Yes. A permit is required for any deck that is above grade level, including decks where the bottom of the structure is on the ground.\"},{\"question\":\"Which code-related items must be included on the permit drawings?\",\"answer\":\"The drawings must include a set of required items that relate to building and zoning compliance and align with the 2019 Residential Code of Ohio.\"},{\"question\":\"What general construction requirements are specified for the deck?\",\"answer\":\"The plans specify pressure-treated lumber, hot-dipped galvanized metal fasteners and hangers, defined design loads, cast-in-place concrete footings with minimum compressive strength, and guard and stair rules including load and spacing constraints.\"}]","Residential Deck Drawings - Permit Requirements and Sample Drawings | PDF"]