[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-370558-105":59,"doc-detail-370558-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","reproducibility-of-mri-derived-radiomic-features-in-prostate-cancer-detection-a-methodological-approach","Reproducibility of MRI-derived radiomic features in prostate cancer detection - a methodological approach","","Purpose: evaluate the reproducibility of MRI-derived radiomic features and use machine learning to predict prostate cancer diagnosis. Material and methods: MR images from 82 individuals (41 prostate cancer, 41 healthy controls) were analyzed; 215 radiomic features were extracted from T2-weighted and ADC images using SERA. Intraclass correlation coefficients (ICC) measured reproducibility, redundant features were removed by Pearson correlation, then dimensionality reduction and 10 classifiers were trained and assessed using accuracy and AUC-ROC. Results and conclusion: reproducible features improved model performance, with PCA as the most effective reduction method.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/reproducibility-of-mri-derived-radiomic-features-in-prostate-cancer-detection-a-methodological-approach/370558/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/reproducibility-of-mri-derived-radiomic-features-in-prostate-cancer-detection-a-methodological-approach/370558.png","ImageObject",300,407,{"name":92,"@type":93},"Alex Sinclair","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-16","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What is the main goal of the study?","Question",{"text":112,"@type":113},"To evaluate the reproducibility of MRI-derived radiomic features and apply machine learning algorithms to predict prostate cancer diagnosis.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How many features and patients were used in the analysis?",{"text":117,"@type":113},"Radiomic extraction produced 215 features from MR images of 82 individuals, including 41 prostate cancer patients and 41 healthy controls.",{"name":119,"@type":110,"acceptedAnswer":120},"How was feature reproducibility assessed and redundant features handled?",{"text":121,"@type":113},"Intraclass correlation coefficient (ICC) analysis quantified reproducibility, and Pearson correlation was used to remove redundant features before model training.",{"name":123,"@type":110,"acceptedAnswer":124},"Which dimensionality reduction method performed best and what impact did it have?",{"text":125,"@type":113},"Principal component analysis (PCA) was the most effective dimensionality reduction method, preserving the discriminative power of reproducible features across all models.","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},370558,1790535752,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":147,"read_time":148,"preview_page_count":19,"preview_urls":149},1099523882182,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","© Pol J Radiol 2025; 90: e180-e188 DOI: [https://doi.org/10.5114/pjr/201467](https://doi.org/10.5114/pjr/201467)  \n[Received: 06.09.2024](Received: 06.09.2024)  \n[Accepted: 15.02.2025](Accepted: 15.02.2025)  \n[Published: 14.04.2025](Published: 14.04.2025)  \n[http://www.polradiol.com](http://www.polradiol.com)  \nOriginal paper  \nReproducibility of MRI-derived radiomic features in prostate cancer detection: a methodological approach  \nJavad Zarei1,A,C,D,E, Asma Soleimani1,A,B,C,E, Marziyeh Tahmasbi2,C,D,F, Mohsen Sarkarian3,B,C, Seyed Masoud Rezaeijo4,A,B,C,D,E,F,G  \n1Department of Health Information Technology, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran 2Department of Radiologic Technology, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran 3Department of Urology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran  \n4Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran  \nAbstract  \nPurpose: We aim to evaluate the reproducibility of these features and apply machine learning algorithms to predict cancer diagnosis.  \nMaterial and methods: We analyzed magnetic resonance (MR) images from a cohort of 82 individuals, split between  \n41 prostate cancer patients and 41 healthy controls. A total of 215 radiomic features were extracted from T2-weighted and ADC images using the Software Environment for Radiomic Analysis (SERA). Intraclass correlation coefficient (ICC) analysis was used to assess the reproducibility of features, and Pearson’s correlation was applied to remove redundant features. After feature selection, seven dimensionality reduction techniques, including principal component analysis (PCA), kernel PCA, linear discriminant analysis, and locally linear embedding, were applied to preprocess the radiomic features. Ten machine learning algorithms, including support vector machines (SVM), random forests, neural networks, logistic regression, and ensemble methods such as CatBoost and AdaBoost, were utilized to classify cancerous versus non-cancerous tissues. Model performance was evaluated using accuracy and AUC-ROC metrics.  \nResults: The results showed that features with high reproducibility (ICC > 0.75) contributed significantly to the performance of machine learning models. SVM, neural networks, and logistic regression achieved the highest accuracy (0.88-0.9) and AUC (up to 0.93) when using features from the good and excellent reproducibility categories. PCA emerged as the most effective dimensionality reduction method, preserving the discriminative power of reproducible features across all models.  \nConclusion: The results indicate that radiomic feature extraction from MR images, combined with dimensionality reduction and machine learning algorithms, provides a robust approach for prostate cancer diagnosis.  \nKeywords: dimensionality reduction, ICC, machine learning, MRI, prostate cancer, radiomics.  \nIntroduction  \nProstate cancer (PCa) stands as a leading health issue for men globally, ranking as the most common cancer among males and the second leading cause of cancer-related deaths [1-4] . While traditional screening methods like  \nprostate-specific antigen (PSA) testing, digital rectal examinations, and transrectal ultrasound-guided biopsies are widely used, they come with significant drawbacks, such as being invasive or having limited accuracy [5] . To address these limitations, multiparametric magnetic resonance imaging (mp-MRI) has emerged as a powerful diagnostic  \nCorrespondence address:  \nSeyed Masoud Rezaeijo, Department of Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran, e-mail: [rezaei-sm@ajums.ac.ir](rezaei-sm@ajums.ac.ir)  \nAuthors’ contribution:  \nA Study design ∙ B Data collection ∙ C Statistical analysis ∙ D Data interpretation ∙ E Manuscript preparation ∙ F Literatur","cbCaihx0A2ENt90S","https://ap.wps.com/l/cbCaihx0A2ENt90S","pdf",191009,"English","# Abstract\n## Purpose\n## Material and methods\n## Results\n## Conclusion\n# Keywords\n# Introduction\n## Background on prostate cancer and current screening\n## Role of mp-MRI and limitations\n## AI/machine learning and CAD approaches\n## Radiomics and reproducibility challenges","[{\"question\":\"What is the main goal of the study?\",\"answer\":\"To evaluate the reproducibility of MRI-derived radiomic features and apply machine learning algorithms to predict prostate cancer diagnosis.\"},{\"question\":\"How many features and patients were used in the analysis?\",\"answer\":\"Radiomic extraction produced 215 features from MR images of 82 individuals, including 41 prostate cancer patients and 41 healthy controls.\"},{\"question\":\"How was feature reproducibility assessed and redundant features handled?\",\"answer\":\"Intraclass correlation coefficient (ICC) analysis quantified reproducibility, and Pearson correlation was used to remove redundant features before model training.\"},{\"question\":\"Which dimensionality reduction method performed best and what impact did it have?\",\"answer\":\"Principal component analysis (PCA) was the most effective dimensionality reduction method, preserving the discriminative power of reproducible features across all models.\"}]","Reproducibility of MRI-derived radiomic features in prostate cancer detection - a methodological approach | PDF",1790189124,23,[150,154,158,162],{"page_no":8,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c208e84e9abc687ef3a155c5c1d992e4.webp",983,1390,{"page_no":14,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/d92e18df593b87824c7daf6188eaa0d2.webp",982,1388,{"page_no":81,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ab2717267e56c2d6a558218dedae1685.webp",981,1387,{"page_no":19,"url":163,"width":164,"height":165},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e5c01c83c0cf8acb126cccd8ac883429.webp",980,1385]