[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-203379-105":59,"doc-detail-203379-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","reno-nv-epa-fasm-base-testing-report-pm-25-clarity-node-s","Reno, NV - EPA FASM Base Testing Report - PM 2.5 Clarity Node-S","","Report documenting v2.1 Global PM2.5 calibration performance for Clarity Node-S sensors deployed in Reno, Nevada by the Northern Nevada Public Health Air Quality Management Division from June 2024 through October 2024. Includes deployment details, sensor/FRM-FEM information, calibration dates, flowrate verification, and maintenance activities. Presents performance metrics for sensor-FRM/FEM accuracy, bias and linearity, correlation (R2), slope/intercept, error measures (RMSE/NRMSE), sensor-sensor precision (CV/SD), uptime, paired value counts, and meteorological influence using normalized concentration with temperature and relative humidity.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/reno-nv-epa-fasm-base-testing-report-pm-25-clarity-node-s/203379/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/reno-nv-epa-fasm-base-testing-report-pm-25-clarity-node-s/203379.png","ImageObject",300,407,{"name":92,"@type":93},"wps_ap_test_251126_0180","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-06","2026-09-04",true,{"@type":102,"interactionType":103,"userInteractionCount":46},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What sensors and reference instruments are used in the PM2.5 base testing?","Question",{"text":112,"@type":113},"Clarity Node-S sensors are evaluated with Met One Instruments, Inc. BAM-1020 as the FRM/FEM reference. The report lists sensor serial numbers and device firmware version, along with calibration and verification information for the reference instrument.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What time period and data sources define the deployment?",{"text":117,"@type":113},"The deployment runs from June 2024 through October 2024, with sampling timeframe listed as 06-07-24 to 10-15-24. Sensor data is sourced from Clarity Cloud, and reference data comes from AirNow API meteorological files from NNPH.",{"name":119,"@type":110,"acceptedAnswer":120},"Which performance metrics are reported for sensor accuracy and precision?",{"text":121,"@type":113},"The report covers sensor-FRM/FEM accuracy using correlation (R2), bias and linearity (slope and intercept), error metrics (RMSE and NRMSE), and data quality measures such as uptime and paired value counts. Sensor-sensor precision is reported via CV (%) and SD for 1-hour and 24-hour aggregation periods.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},203379,1788560427,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":46,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":39},8796095027276,"https://avatar.qwps.com/avatar/d3BzX2FwX3Rlc3RfMjUxMTI2XzAxODA=","Testing Report-PM 2.5 Base Testing Clarity Node-S  \nThis report reflects the v2.1 Global PM2.5 Calibration performance  \nReno, NV  \nNorthern Nevada Public Health Air Quality Management Division  \nJune 2024—October 2024  \n|  |  |  | Deployment Details\u003Cbr>Sensor Information Manufacturer, model Clarity Node-S Device firmware version [2.4.1.01](2.4.1.01) Sampling time interval 1-hour Sensor serial numbers AMGHCPFP AN6R7Y47 A4JFGM4L Issues encountered during deployment? 􀂅 No Issues\u003Cbr>FRM/FEM Information Manufacturer, model, designation Met One Instruments, Inc. BAM-1020 VSCC Sampling time interval 1 Hour Date of calibration 07/15/24 (BP cal only)\u003Cbr>08/14/24 (BP cal only)\u003Cbr>10/07/24 (BP cal only) Date of flowrate verification check 06/17/24, 07/01/24, 07/15/24, 07/31/24, 08/14/24, 08/26/24, 09/09/24, 09/23/24, 10/07/24, 10/14/24 – semi-annual flow audit Description, date(s) of maintenance activities 06/17/24 – smart heater , RH, and filter temp test; span membrane test , beta detector count, dark count\u003Cbr>07/01/24 – PM10 inlet, PM2.5 VSCC, nozzle, vane, capstan shaft , and pinch rol ler maint\u003Cbr>07/11/24 – filter tape replacement\u003Cbr>07/31/24 – PM10 inlet, PM2.5 VSCC, nozzle, vane, capstan shaft , and pinch rol ler maint\u003Cbr>08/26/24 – PM10 inlet, PM2.5 VSCC, nozzle, vane, capstan shaft , and pinch rol ler maint\u003Cbr>09/09/24 – filter tape replacement\u003Cbr>09/23/24 – PM10 inlet, PM2.5 VSCC, nozzle, vane, capstan shaft , and pinch rol ler maint |\n| --- | --- | --- | --- |\n|  | Testing Organization and Site Information |  |  |\n|  | Testing organization\u003Cbr>(Name, Organization type, Contact website) | Northern Nevada Public Health Air Quality Management Division |  |\n|  | Testing location\u003Cbr>(City, State, Latitude and Longitude) | Reno4\u003Cbr>Reno, NV\u003Cbr>39. 52, -119.8 |  |\n|  | AQS site ID | 32-031-0031 |  |\n|  | Sampling timeframe\u003Cbr>(MM-DD-YY) | 06-07-24 to 10-15-24 |  |\n|  | Sensor data source | Clarity Cloud |  |\n|  | Reference data source | PM2.5 : AirNow API Meteorological: Files from NNPH |  |\n|  |  |  |  |\n\nPerformance Metrics  \nSensor-FRM/FEM Accuracy Sensor-Sensor Precision  \nMeteorological Conditions During Deployment  \n| Number of 24-hr periods outside sensor manufacture-listed temperature operational range (no operational range specified) | - |\n| --- | --- |\n| Number of 24-hr periods outside sensor manufacture-listed relative humidity operational range (no operational range specified) | - |\n\nMeteorological Influence  \n\n| Mean number of paired, normalized concentration and temperature values (1-hr averages) | 3116 |\n| --- | --- |\n| Mean number of paired, normalized concentration and relative humidity values (1-hr averages) | 3116 |\n\nTesting Report-PM 2.5 Base Testing Clarity Node-S  \nThis report reflects the v2.1 Global PM2.5 Calibration performance  \nReno, NV  \nNorthern Nevada Public Health Air Quality Management Division  \nJune 2024—October 2024  \nTabular Statistics  \nSensor-FRM/FEM Correlation  \n\n|  | Bias and Linearity |  |  |  |  |  | Data Quality |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | R2 |  | Slope |  | Intercept (µg/m³) |  | Uptime (%) |  | Number of paired sensor and FRM/FEM concentration values |  |\n|  | 1-Hour ●●● | 24-Hour ●●● | 1-Hour ●●● | 24-Hour ●●● | 1-Hour ●●● | 24-Hour ●●● | 1-Hour ●●● | 24-Hour ●●● | 1-Hour | 24-Hour |\n| Metric Target Range | ≥ 0.70 | ≥ 0.70 | 1.0 ± 0.35 | 1.0 ± 0.35 | -5 ≤ b ≤ 5 | -5 ≤ b ≤ 5 | 75%* | 75%* | - | - |\n| Sensor AMGHCPFP | 0.86 | 0.93 | 1.06 | 1.21 | 1.60 | 0.78 | 100 | 100 | 3053 | 127 |\n| Sensor AN6R7Y47 | 0.86 | 0.93 | 1.08 | 1.24 | 1.69 | 0.85 | 100 | 100 | 3055 | 127 |\n| Sensor A4JFGM4L | 0.86 | 0.93 | 1.09 | 1.24 | 1.68 | 0.84 | 100 | 100 | 3054 | 127 |\n| Mean | 0.86 | 0.93 | 1.08 | 1.23 | 1.66 | 0.82 | 100 | 100 | 3054 | 127 |\n\n\n|  | Error |  |  |  |\n| --- | --- | --- | --- | --- |\n|  | RMSE (µg/m³) |  | NRMSE (%) |  |\n|  | 1-Hour ★ | 24-Hour ★ | 1-Hour ☆ | 24-Hour ☆ |\n| Metric Target Range | ≤ 7.0 | ≤ 7.0 | ≤ 30.0 | ≤ 30.0 |\n| De","cbCaimJIbc5YaTme","https://ap.wps.com/l/cbCaimJIbc5YaTme","pdf",1657380,"English","# Testing Report-PM 2.5 Base Testing Clarity Node-S\n## Deployment Details\n## Testing Organization and Site Information\n## Performance Metrics\n## Sensor-FRM/FEM Correlation\n## Sensor-Sensor Precision\n## Meteorological Conditions During Deployment\n## Meteorological Influence\n## Sensor-FRM/FEM Scatter Plots","[{\"question\":\"What sensors and reference instruments are used in the PM2.5 base testing?\",\"answer\":\"Clarity Node-S sensors are evaluated with Met One Instruments, Inc. BAM-1020 as the FRM/FEM reference. The report lists sensor serial numbers and device firmware version, along with calibration and verification information for the reference instrument.\"},{\"question\":\"What time period and data sources define the deployment?\",\"answer\":\"The deployment runs from June 2024 through October 2024, with sampling timeframe listed as 06-07-24 to 10-15-24. Sensor data is sourced from Clarity Cloud, and reference data comes from AirNow API meteorological files from NNPH.\"},{\"question\":\"Which performance metrics are reported for sensor accuracy and precision?\",\"answer\":\"The report covers sensor-FRM/FEM accuracy using correlation (R2), bias and linearity (slope and intercept), error metrics (RMSE and NRMSE), and data quality measures such as uptime and paired value counts. Sensor-sensor precision is reported via CV (%) and SD for 1-hour and 24-hour aggregation periods.\"}]","Reno, NV - EPA FASM Base Testing Report - PM 2.5 Clarity Node-S | PDF"]